Literature DB >> 19885360

Clinical overview of continuous glucose monitoring.

Bruce Buckingham1.   

Abstract

Continuous glucose monitoring (CGM) is now available from several companies in the United States for purchase or research studies. This article provides an overview of these devices and reviews the use of sensors for managing diabetes in "real time," as well as the use of retrospective analysis of CGM results.

Entities:  

Keywords:  continuous glucose monitoring

Year:  2008        PMID: 19885360      PMCID: PMC2771500          DOI: 10.1177/193229680800200223

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  13 in total

1.  Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex.

Authors:  Jannik Kruse Nielsen; Christian Born Djurhuus; Claus Højbjerg Gravholt; Andreas Christiansen Carus; Jacob Granild-Jensen; Hans Orskov; Jens Sandahl Christiansen
Journal:  Diabetes       Date:  2005-06       Impact factor: 9.461

2.  Response to nocturnal alarms using a real-time glucose sensor.

Authors:  Bruce Buckingham; Jen Block; Jonathan Burdick; Andrea Kalajian; Craig Kollman; Michael Choy; Darrell M Wilson; Peter Chase
Journal:  Diabetes Technol Ther       Date:  2005-06       Impact factor: 6.118

3.  Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial.

Authors:  Satish Garg; Howard Zisser; Sherwyn Schwartz; Timothy Bailey; Roy Kaplan; Samuel Ellis; Lois Jovanovic
Journal:  Diabetes Care       Date:  2006-01       Impact factor: 19.112

4.  Continuous glucose monitoring in children with type 1 diabetes.

Authors:  Bruce Buckingham; Roy W Beck; William V Tamborlane; Dongyuan Xing; Craig Kollman; Rosanna Fiallo-Scharer; Nelly Mauras; Katrina J Ruedy; Michael Tansey; Stuart A Weinzimer; Tim Wysocki
Journal:  J Pediatr       Date:  2007-08-24       Impact factor: 4.406

5.  The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes.

Authors:  Darrell M Wilson; Roy W Beck; William V Tamborlane; Mariya J Dontchev; Craig Kollman; Peter Chase; Larry A Fox; Katrina J Ruedy; Eva Tsalikian; Stuart A Weinzimer
Journal:  Diabetes Care       Date:  2007-01       Impact factor: 19.112

6.  Accuracy of the modified Continuous Glucose Monitoring System (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study.

Authors:  Michael J Tansey; Roy W Beck; Bruce A Buckingham; Nelly Mauras; Rosanna Fiallo-Scharer; Dongyuan Xing; Craig Killman; William V Tamborlane; Katrina J Ruedy
Journal:  Diabetes Technol Ther       Date:  2005-02       Impact factor: 6.118

7.  Accuracy of newer-generation home blood glucose meters in a Diabetes Research in Children Network (DirecNet) inpatient exercise study.

Authors:  Stuart A Weinzimer; Roy W Beck; H Peter Chase; Larry A Fox; Bruce A Buckingham; William V Tamborlane; Craig Kollman; Julie Coffey; Dongyuan Xing; Katrina J Ruedy
Journal:  Diabetes Technol Ther       Date:  2005-10       Impact factor: 6.118

8.  Hypoglycemia: incidence and clinical predictors in a large population-based sample of children and adolescents with IDDM.

Authors:  E A Davis; B Keating; G C Byrne; M Russell; T W Jones
Journal:  Diabetes Care       Date:  1997-01       Impact factor: 19.112

9.  GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children.

Authors:  Eva Tsalikian; Craig Kollman; Nelly Mauras; Stuart Weinzimer; Bruce Buckingham; Dongyuan Xing; Roy Beck; Katrina Ruedy; William Tamborlane; Rosanna Fiallo-Scharer
Journal:  Diabetes Technol Ther       Date:  2004-10       Impact factor: 6.118

10.  Use of the DirecNet Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the FreeStyle Navigator).

Authors:  Bruce Buckingham; Dongyuan Xing; Stu Weinzimer; Rosanna Fiallo-Scharer; Craig Kollman; Nelly Mauras; Eva Tsalikian; William Tamborlane; Tim Wysocki; Katrina Ruedy; Roy Beck
Journal:  Pediatr Diabetes       Date:  2008-01-24       Impact factor: 4.866

View more
  7 in total

1.  Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

Review 2.  Utility of different glycemic control metrics for optimizing management of diabetes.

Authors:  Klaus-Dieter Kohnert; Peter Heinke; Lutz Vogt; Eckhard Salzsieder
Journal:  World J Diabetes       Date:  2015-02-15

Review 3.  Fault detection and safety in closed-loop artificial pancreas systems.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2014-07-21

4.  A MEMS differential viscometric sensor for affinity glucose detection in continuous glucose monitoring.

Authors:  Xian Huang; Siqi Li; Erin Davis; Charles Leduc; Yann Ravussin; Haogang Cai; Bing Song; Dachao Li; Domenico Accili; Rudolph Leibel; Qian Wang; Qiao Lin
Journal:  J Micromech Microeng       Date:  2013-05       Impact factor: 1.881

5.  How effective is continuous glucose monitoring in intensively treated type 1 diabetes mellitus?

Authors:  Joseph I Wolfsdorf
Journal:  Nat Clin Pract Endocrinol Metab       Date:  2009-03

Review 6.  "Smart" continuous glucose monitoring sensors: on-line signal processing issues.

Authors:  Giovanni Sparacino; Andrea Facchinetti; Claudio Cobelli
Journal:  Sensors (Basel)       Date:  2010-07-12       Impact factor: 3.576

Review 7.  The methodology of glucose monitoring in type 2 diabetes mellitus.

Authors:  Mihaela Gribovschi
Journal:  Clujul Med       Date:  2013-05-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.