Literature DB >> 16024994

Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation.

Thomas C Gerber1, Brian P Stratmann, Ronald S Kuzo, Birgit Kantor, Richard L Morin.   

Abstract

RATIONALE AND
OBJECTIVES: We sought to examine effects of tube voltage and current on radiation dose and image quality for minimally invasive coronary angiography with a 16-slice multidetector row computed tomography (MDCT) scanner.
MATERIALS AND METHODS: We scanned the phantom used in the American College of Radiology Computed Tomography Accreditation Program at tube voltages of 80 and 120 kVp at 550, 650, and 750 mAseff, with and without a reduction in radiation dose by electrocardiographically (ECG) controlled tube current modulation (ECG pulsing).
RESULTS: Without ECG pulsing, the effective dose was 3 to 13 mSv. On average, a 50% increase in tube voltage led to increased radiation dose (215%), contrast-to-noise ratio (150%), and decreased image noise (-48%). On average, a 17% increase in mAseff led to increased radiation dose (17%) and contrast-to-noise ratio (4%) and decreased image noise (-9%). Dose reduction by ECG pulsing (simulated heart rate, 70 beats per minute) was 28%. With ECG pulsing, noise in images reconstructed during ventricular systole was double that in images reconstructed during ventricular diastole.
CONCLUSIONS: These quantitative findings about the relationships among scan acquisition parameters, radiation dose, and image quality have practical implications for using ECG pulsing to reduce radiation doses in MDCT coronary angiography.

Entities:  

Mesh:

Year:  2005        PMID: 16024994     DOI: 10.1097/01.rli.0000170628.69792.cb

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  15 in total

Review 1.  Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography.

Authors:  Thomas C Gerber; Ronald S Kuzo; Richard L Morin
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

2.  Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses.

Authors:  Dirk Schnapauff; Hans-Peter Dübel; Jürgen Scholze; Gert Baumann; Bernd Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

Review 3.  Cardiac CT: coronary arteries and beyond.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-10-26       Impact factor: 5.315

Review 4.  Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography.

Authors:  D Schnapauff; F Teige; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

5.  Dose reduction in spiral CT coronary angiography with dual source equipment. Part II. Dose surplus due to slope-up and slope-down of prospective tube current modulation in a phantom model.

Authors:  C Martini; A Palumbo; E Maffei; A Rossi; M Rengo; R Malagò; M Dijkshoorn; A Weustink; N Mollet; G Krestin; F Cademartiri
Journal:  Radiol Med       Date:  2010-02       Impact factor: 3.469

6.  Dose reduction in spiral CT coronary angiography with dual-source equipment. Part I. A phantom study applying different prospective tube current modulation algorithms.

Authors:  C Martini; A Palumbo; E Maffei; A Rossi; M Rengo; R Malagò; M Dijkshoorn; A Weustink; N Mollet; G Krestin; F Cademartiri
Journal:  Radiol Med       Date:  2009-08-07       Impact factor: 3.469

7.  Current and future status on cardiac computed tomography imaging for diagnosis and risk stratification.

Authors:  Stephan Achenbach
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

8.  Declining radiation dose of coronary computed tomography angiography: German cardiac CT registry experience 2009-2014.

Authors:  Axel Schmermund; Mohamed Marwan; Jörg Hausleiter; Sebastian Barth; Oliver Bruder; Sebastian Kerber; Grigorius Korosoglou; Alexander Leber; Werner Moshage; Stephen Schröder; Steffen Schneider; Jochen Senges; Stephan Achenbach
Journal:  Clin Res Cardiol       Date:  2017-07-19       Impact factor: 5.460

9.  CT in the evaluation of congenital heart disease in children, adolescents, and young adults.

Authors:  Sanjeev Bhalla; Cylen Javidan-Nejad; Andrew J Bierhals; Pamela K Woodard; Fernando R Gutierrez
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-09

10.  Accuracy of quantitative coronary angiography with computed tomography and its dependency on plaque composition: plaque composition and accuracy of cardiac CT.

Authors:  Lars Husmann; Oliver Gaemperli; Tiziano Schepis; Hans Scheffel; Ines Valenta; Tobias Hoefflinghaus; Paul Stolzmann; Lotus Desbiolles; Bernhard A Herzog; Sebastian Leschka; Borut Marincek; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2008-06-19       Impact factor: 2.357