Low dose dual-source CT angiography of the thoracic aorta.

Cormac Farrelly1, Amir Davarpanah, Aoife N Keeling, John Sheehan, Ann Ragin, Vahid Yaghmai, James C Carr.   

Abstract

The purpose of this study was to investigate the effects of a prospective ECG-gated, low kilovoltage and low mAs protocol on image quality and radiation dose when acquiring CT angiography of the thoracic aorta (CTTA). Sixty patients with a body mass index (BMI) of less than 30 and a heart rate of less than 100 beats per minute (bpm) were included in the study. Thirty consecutive patients were examined with retrospective ECG-gating and standard parameters (group A) (120 kVp, 340 reference effective mAs).The next thirty (group B) were examined with prospective ECG-gating, 100 kVp and 170 mAs. Quantitative analysis included measurements of image resolution of the thoracic aorta at three levels, mean attenuation in the aorta and signal to noise ratio (SNR). Qualitative analysis assessed image artifact and graded image quality on five point scales. Effective radiation doses were estimated. The radiation dose of group A was 26.2 ± 6.0 mSv (mean ± standard deviation). For group B it was 2.9 ± 0.5 mSv (P < 0.001). Mean aortic attenuation was significantly higher in group B than group A (487 ± 100 Hu and 372 ± 74 Hu) (P < 0.01).SNR was significantly higher in group A (21.7 ± 5.7 compared to 14.5 ± 5.3) (P < 0.01). Image resolution was significantly higher in group B at all measured anatomical levels (P < 0.01). There was no significant difference in the final subjective scores between group A and group B (Mann-Whitney U = 438, P = 0.79). High quality low dose CTTA is clinically achievable, in patients with a BMI less than 30 and a heart rate less than 100 bpm, using a prospective ECG-gated, low kilovoltage, low mAs technique.

Entities:  

Mesh:

Year:  2010        PMID: 21046253     DOI: 10.1007/s10554-010-9742-9

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  37 in total

1.  Stair-step artifacts with single versus multiple detector-row helical CT.

Authors:  D Fleischmann; G D Rubin; D S Paik; S Y Yen; P R Hilfiker; C F Beaulieu; S Napel
Journal:  Radiology       Date:  2000-07       Impact factor: 11.105

2.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

3.  Thoracic aorta: motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT.

Authors:  Justus E Roos; Jürgen K Willmann; Dominik Weishaupt; Mario Lachat; Borut Marincek; Paul R Hilfiker
Journal:  Radiology       Date:  2002-01       Impact factor: 11.105

4.  High-resolution breath-hold contrast-enhanced MR angiography of the entire carotid circulation.

Authors:  James C Carr; Jason Ma; Vibhas Desphande; Scott Pereles; Gerhard Laub; J Paul Finn
Journal:  AJR Am J Roentgenol       Date:  2002-03       Impact factor: 3.959

Review 5.  Vascular diseases of the thorax: evaluation with multidetector CT.

Authors:  Caroline Chiles; J Jeffrey Carr
Journal:  Radiol Clin North Am       Date:  2005-05       Impact factor: 2.303

Review 6.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

7.  Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.

Authors:  Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-08       Impact factor: 6.016

8.  Dynamic aortic changes in patients with thoracic aortic aneurysms evaluated with electrocardiography-triggered computed tomographic angiography before and after thoracic endovascular aneurysm repair: preliminary results.

Authors:  Joffrey van Prehn; Lambertus W Bartels; Gaspar Mestres; Koen L Vincken; Mathias Prokop; Hence J M Verhagen; Frans L Moll; Joost A van Herwaarden
Journal:  Ann Vasc Surg       Date:  2008-09-21       Impact factor: 1.466

9.  Comparison of retrospectively ECG-gated and nongated MDCT of the chest in an emergency setting regarding workflow, image quality, and diagnostic certainty.

Authors:  Thomas Schertler; Thomas Glücker; Simon Wildermuth; Karl-Peter Jungius; Borut Marincek; Thomas Boehm
Journal:  Emerg Radiol       Date:  2005-11-09

Review 10.  Technical principles of dual source CT.

Authors:  Martin Petersilka; Herbert Bruder; Bernhard Krauss; Karl Stierstorfer; Thomas G Flohr
Journal:  Eur J Radiol       Date:  2008-10-07       Impact factor: 3.528

View more
  3 in total

1.  Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study.

Authors:  D Ippolito; C Talei Franzesi; D Fior; P A Bonaffini; O Minutolo; S Sironi
Journal:  Br J Radiol       Date:  2015-03-18       Impact factor: 3.039

2.  Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure.

Authors:  Cammillo R Talei Franzesi; Davide Ippolito; Luca Riva; Davide Fior; Cecilia Cangiotti; Sandro Sironi
Journal:  Br J Radiol       Date:  2018-08-13       Impact factor: 3.039

Review 3.  Cardiovascular magnetic resonance in Marfan syndrome.

Authors:  Helen Dormand; Raad H Mohiaddin
Journal:  J Cardiovasc Magn Reson       Date:  2013-04-15       Impact factor: 5.364

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.