Literature DB >> 23283753

A GSO tweezers-type coincidence detector for tumor detection.

Seiichi Yamamoto1, Tatsuya Higashi, Michio Senda.   

Abstract

A Gd2SiO5 (GSO) tweezers-type coincidence detector was developed and tested for tumor detection in procedures such as (18)F-fluorodeoxyglucose (FDG)-guided surgery. The detector consists of a pair of GSO scintillators, a pair of metal-packaged small-sized photomultiplier tubes (PMTs), and a coincidence circuit. Because the GSO scintillators are located on the tips of tweezers, a target organ such as a lymph node or the colon can be easily positioned between them. The size of a single GSO was 8 × 14 × 14 mm. The results show that the energy resolution was 30 % full-width at half-maximum (FWHM) and the timing resolution was 6 ns FWHM for 511-keV gamma photons. The point-spread function perpendicular to the detector was 4.5 mm FWHM, and the point-spread function parallel to the detector was 7.5 mm FWHM. The absolute sensitivity of the coincidence detector was 0.6% at the center of the detector when the two GSOs were 5 mm apart. Background counts due to the accidental and scatter coincidence were 2 cps up to 48 MBq from the positron source contained in a 20-cm-diameter, 20-cm-high cylindrical phantom. From these results, we conclude that the proposed tweezers-type coincidence detector is useful for tumor detection by the use of FDG, such as that in radio-guided surgery.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23283753     DOI: 10.1007/s12194-012-0198-6

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  10 in total

Review 1.  Positronium: review of symmetry, conserved quantities and decay for the radiological physicist.

Authors:  Michael D Harpen
Journal:  Med Phys       Date:  2004-01       Impact factor: 4.071

2.  Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET.

Authors:  Seiichi Yamamoto; Hitoshi Horii; Mitsuru Hurutani; Keiichi Matsumoto; Michio Senda
Journal:  Ann Nucl Med       Date:  2005-04       Impact factor: 2.668

3.  Performance comparison of high quantum efficiency and normal quantum efficiency photomultiplier tubes and position sensitive photomultiplier tubes for high resolution PET and SPECT detectors.

Authors:  Seiichi Yamamoto; Hiroshi Watabe; Katsuhiko Kato; Jun Hatazawa
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

4.  An intra-operative positron probe with background rejection capability for FDG-guided surgery.

Authors:  Seiichi Yamamoto; Keiichi Matsumoto; Setsu Sakamoto; Kazumasa Tarutani; Kotaro Minato; Michio Senda
Journal:  Ann Nucl Med       Date:  2005-02       Impact factor: 2.668

5.  18F-labeled fluorodeoxyglucose positron emission tomography-guided surgery for recurrent colorectal cancer: a feasibility study.

Authors:  E E Zervos; D C Desai; L R DePalatis; D Soble; E W Martin
Journal:  J Surg Res       Date:  2001-05-01       Impact factor: 2.192

Review 6.  Intraoperative probes and imaging probes.

Authors:  E J Hoffman; M P Tornai; M Janecek; B E Patt; J S Iwanczyk
Journal:  Eur J Nucl Med       Date:  1999-08

7.  Performance of a dual, solid-state intraoperative probe system with 18F, 99mTc, and (111)In.

Authors:  R R Raylman
Journal:  J Nucl Med       Date:  2001-02       Impact factor: 10.057

8.  Application of an [(18)F]fluorodeoxyglucose-sensitive probe for the intraoperative detection of malignancy.

Authors:  R Essner; E C Hsueh; P I Haigh; E C Glass; Y Huynh; F Daghighian
Journal:  J Surg Res       Date:  2001-03       Impact factor: 2.192

9.  Correlative Whole-Body FDG-PET and Intraoperative Gamma Detection of FDG Distribution in Colorectal Cancer.

Authors:  D C. Desai; M Arnold; S Saha; G Hinkle; D Soble; J Fry; L R. DePalatis; J Mantil; M Satter; E W. Martin
Journal:  Clin Positron Imaging       Date:  2000-09

Review 10.  From tumor biology to clinical Pet: a review of positron emission tomography (PET) in oncology.

Authors:  K Kubota
Journal:  Ann Nucl Med       Date:  2001-12       Impact factor: 2.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.