Literature DB >> 15865125

Radiograph-based femur morphing method.

E M Zanetti1, V Crupi, C Bignardi, P M Calderale.   

Abstract

Many applications in orthopaedic surgery require the creation of personalised design models that can serve as the basis for navigation in computer aided surgery systems or be used to create a personalised model to perform structural analysis during pre-operative planning or post-operative follow-up. The paper introduces a method for developing a three-dimensional (3D) patient-specific model of a femur bone from an antero-posterior radiograph. A generic femur was employed and was altered on the basis of bone boundaries visible on radiographs. Morphological errors were evaluated against 3D models obtained from computed tomography (CT) scans. When only the antero-posterior radiograph was used, the average radius estimation error was 4.8 mm, the average percentage area estimation error was 14%, and the average percentage estimation error for inertial moments was 15%. If both the medial-lateral and the anterior-posterior radiographs were used, these errors were 2.0 mm, 5% and 7%, respectively. The procedure described can be profitably employed whenever CT scans are not available, such as during a retrospective analysis, or when CT scans cannot be justified because of X-ray exposure and cost considerations.

Entities:  

Mesh:

Year:  2005        PMID: 15865125     DOI: 10.1007/bf02345952

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  19 in total

1.  Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering.

Authors:  Banchong Mahaisavariya; Kriskrai Sitthiseripratip; Trongtum Tongdee; Erik L J Bohez; Jos Vander Sloten; Philip Oris
Journal:  Med Eng Phys       Date:  2002-11       Impact factor: 2.242

2.  Femoral anatomy, computed tomography and computer-aided design of prosthetic implants.

Authors:  Frank Adam; D S Hammer; D Pape; D Kohn
Journal:  Arch Orthop Trauma Surg       Date:  2002-01-12       Impact factor: 3.067

3.  On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

Authors:  Julia Orlik; Alexei Zhurov; John Middleton
Journal:  Med Eng Phys       Date:  2003-12       Impact factor: 2.242

4.  The 'standardized femur program' proposal for a reference geometry to be used for the creation of finite element models of the femur.

Authors:  M Viceconti; M Casali; B Massari; L Cristofolini; S Bassini; A Toni
Journal:  J Biomech       Date:  1996-09       Impact factor: 2.712

5.  Three-dimensional morphology of the proximal femur.

Authors:  O Husmann; P J Rubin; P F Leyvraz; B de Roguin; J N Argenson
Journal:  J Arthroplasty       Date:  1997-06       Impact factor: 4.757

6.  The anatomic basis of femoral component design.

Authors:  P C Noble; J W Alexander; L J Lindahl; D T Yew; W M Granberry; H S Tullos
Journal:  Clin Orthop Relat Res       Date:  1988-10       Impact factor: 4.176

7.  Use of general purpose mechanical computer assisted engineering software in orthopaedic surgical planning: advantages and limitations.

Authors:  C J Sutherland; S J Bresina; D E Gayou
Journal:  Comput Med Imaging Graph       Date:  1994 Nov-Dec       Impact factor: 4.790

8.  Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants.

Authors:  W L Bargar
Journal:  Clin Orthop Relat Res       Date:  1989-12       Impact factor: 4.176

9.  Three-dimensional morphological analysis of the proximal femoral canal, using computer-aided design system, in Japanese patients with osteoarthrosis of the hip.

Authors:  A Kaneuji; T Matsumoto; M Nishino; T Miura; T Sugimori; K Tomita
Journal:  J Orthop Sci       Date:  2000       Impact factor: 1.601

10.  Validation data for periprosthetic bone remodelling theories.

Authors:  Markus Lengsfeld; Daniel Günther; Thomas Pressel; Ronald Leppek; Jan Schmitt; Peter Griss
Journal:  J Biomech       Date:  2002-12       Impact factor: 2.712

View more
  3 in total

1.  Using two palpable measurements improves the subject-specific femoral modeling.

Authors:  Weidong Luo; Steven J Stanhope; Frances T Sheehan
Journal:  J Biomech       Date:  2009-06-10       Impact factor: 2.712

Review 2.  Multibody modelling of ligamentous and bony stabilizers in the human elbow.

Authors:  Mara Terzini; Elisabetta Maria Zanetti; Alberto Luigi Audenino; Giovanni Putame; Laura Gastaldi; Stefano Pastorelli; Elisa Panero; Arman Sard; Cristina Bignardi
Journal:  Muscles Ligaments Tendons J       Date:  2018-04-16

3.  Digital Design of Medical Replicas via Desktop Systems: Shape Evaluation of Colon Parts.

Authors:  Michele Bici; Valerio Cardini; Marco Eugeni; Robinson Guachi; Fabiano Bini; Francesca Campana; Franco Marinozzi; Paolo Gaudenzi
Journal:  J Healthc Eng       Date:  2018-11-14       Impact factor: 2.682

  3 in total