Literature DB >> 2582679

Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants.

W L Bargar1.   

Abstract

Most authors agree that "fit" and "fill" of the endosteal canal is critical to the success of cementless femoral components. Yet, there exists a wide variation to the anatomic size and shape of this canal in the normal population. This paper reviews the rationale and the efficacy of using a computed tomography-generated CAD/CAM custom femoral component in cementless total hip arthroplasty. One hundred fifty-six cases (81 primary and 75 revisions) were reviewed with follow-up time of six weeks to three years (mean, 22 months). A subset of 48 hips (25 primary and 23 revisions) has been followed a minimum of two years. For the primary hips, the custom group was found to have statistically higher Harris pain scores (less pain) at all follow-up intervals as compared to a prior series by the same surgeon using an off-the-shelf (OTS) prosthesis. Revision customized hip implants had lower Harris pain and total scores than primary custom hips, but 80% were in the none or slight pain category. In revision cases, the use of custom components decreased the need for structural bone grafting and achieved stability on host bone in situations in which it was not possible using OTS components. Complications included failure by aseptic loosening of one primary and one revision case. Initial subsidence of more than 3 mm of the collarless custom design occurred in 8%, the majority being in revision cases. All cases but one appear to have stabilized. Subsidence occurred mainly in cases done early in the series.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2582679

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  13 in total

1.  The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty.

Authors:  Li-dong Wu; H J Hahne; J Hassenpflug
Journal:  J Zhejiang Univ Sci       Date:  2004-10

2.  Radiograph-based femur morphing method.

Authors:  E M Zanetti; V Crupi; C Bignardi; P M Calderale
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

3.  Custom cementless THA in patients with skeletal dysplasia results in lower apparent revision rates than other types of femoral fixation.

Authors:  Mathew D Sewell; Sammy A Hanna; Sarah K Muirhead-Allwood; Stephen R Cannon; Timothy W R Briggs
Journal:  Clin Orthop Relat Res       Date:  2010-11-02       Impact factor: 4.176

4.  Uncemented custom femoral components in hip arthroplasty. A prospective clinical study of 191 hips followed for at least 7 years.

Authors:  Pål Benum; Arild Aamodt
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

5.  Custom cementless stem improves hip function in young patients at 15-year followup.

Authors:  Xavier Flecher; Oliver Pearce; Sebastien Parratte; Jean-Manuel Aubaniac; Jean-Noel Argenson
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

6.  Patient-specific devices and population-level evidence: evaluating therapeutic interventions with inherent variation.

Authors:  Mary Jean Walker
Journal:  Med Health Care Philos       Date:  2018-09

7.  Periprosthetic bone loss after insertion of an uncemented, customized femoral stem and an uncemented anatomical stem. A randomized DXA study with 5-year follow-up.

Authors:  Mona Nysted; Pål Benum; Jomar Klaksvik; Olav Foss; Arild Aamodt
Journal:  Acta Orthop       Date:  2011-06-14       Impact factor: 3.717

8.  Custom stems for femoral deformity in patients less than 40 years of age: 70 hips followed for an average of 14 years.

Authors:  Michael Akbar; Guenther Aldinger; Knut Krahmer; Thomas Bruckner; Peter R Aldinger
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

9.  Small stem total hip arthroplasty in hypoplasia of the femur.

Authors:  F Harald R De Man; Daniel Haverkamp; Harm M Van der Vis; Philip P Besselaar; René K Marti
Journal:  Clin Orthop Relat Res       Date:  2008-03-15       Impact factor: 4.176

10.  RAPID MANUFACTURING SYSTEM OF ORTHOPEDIC IMPLANTS.

Authors:  Carlos Relvas; Joana Reis; José Alberto Caeiro Potes; Fernando Manuel Ferreira Fonseca; José Antonio Oliveira Simões
Journal:  Rev Bras Ortop       Date:  2015-11-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.