Literature DB >> 12445608

Validation data for periprosthetic bone remodelling theories.

Markus Lengsfeld1, Daniel Günther, Thomas Pressel, Ronald Leppek, Jan Schmitt, Peter Griss.   

Abstract

Periprosthetic adaptive bone remodelling after total hip arthroplasty (THA) has been frequently simulated in computer models, combining bone remodelling theory with finite element analysis. Unfortunately, there still subsist a lack of clinical data, which are necessary for validation of these simulation results. Therefore, the objective of the current project is to collect prospective volumetric bone density data with a clinical computerized tomography study in seven patients after THA. A retrospective study 12 years after implantation in 11 patients was added. A data set of about 100000 bone voxels for each femur was collected. In all prospective cases, the predominant change is seen during the first year. The average density reduction in the horizontal slices was between 50 and 150 Hounsfield units (HU) (approx. 10%; p<0.001) after 2 years. Loss of density is particularly strong distal of the minor trochanter and decreases from proximal to distal. For the 12 years retrospective study, the contralateral femur provided the control. Similar trends comparable to the prospective 2-year follow-up CT density values were seen in most cases with density reductions of up to 400 HU (30%). However, in one of these cases there was no difference between the operated and the control density. As far as we are aware, this is the first collection of fully prospective 3D validation data in vivo for periprosthetic adaptive bone remodelling theories. The data are also unique as they are suitable for direct patient-specific 3D finite element meshing and individual weight-related loading.

Entities:  

Mesh:

Year:  2002        PMID: 12445608     DOI: 10.1016/s0021-9290(02)00187-2

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  13 in total

1.  Radiograph-based femur morphing method.

Authors:  E M Zanetti; V Crupi; C Bignardi; P M Calderale
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

2.  Prospective bone density changes after periacetabular osteotomy: a methodological study.

Authors:  I Mechlenburg; J R Nyengaard; L Rømer; K Søballe
Journal:  Int Orthop       Date:  2005-06-17       Impact factor: 3.075

3.  Periprosthetic bone remodelling in total knee arthroplasty.

Authors:  Vlad Georgeanu; Tudor Atasiei; Lucian Gruionu
Journal:  Maedica (Buchar)       Date:  2014-03

4.  Impact of mechanical stability on the progress of bone ongrowth on the frame surfaces of a titanium-coated PEEK cage and a 3D porous titanium alloy cage: in vivo analysis using CT color mapping.

Authors:  Takahiro Makino; Shota Takaneka; Yusuke Sakai; Hideki Yoshikawa; Takashi Kaito
Journal:  Eur Spine J       Date:  2021-01-03       Impact factor: 3.134

5.  Bone remodelling around the Metha® short stem implant - Clinical and dual-energy x-ray absorptiometry (DXA) results.

Authors:  Markus Fischer; Nicholas A Beckmann; Hans-Georg Simank
Journal:  J Orthop       Date:  2017-08-09

6.  Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova; Jiri Lostak
Journal:  BMC Musculoskelet Disord       Date:  2010-10-19       Impact factor: 2.362

7.  Osteodensitometry after total hip replacement with uncemented taper-design stem.

Authors:  Rainer Schmidt; Tobias E Nowak; Lutz Mueller; Rocco P Pitto
Journal:  Int Orthop       Date:  2003-10-24       Impact factor: 3.075

8.  Evaluation of early tissue reactions after lumbar intertransverse process fusion using CT in a rabbit.

Authors:  Jun Shinbo; Pierre Mainil-Varlet; Atsuya Watanabe; Suzanne Pippig; Jens Koener; Suzanne E Anderson
Journal:  Skeletal Radiol       Date:  2009-06-25       Impact factor: 2.199

9.  Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: influence of the boundary conditions.

Authors:  Bernd-Arno Behrens; Ingo Nolte; Patrick Wefstaedt; Christina Stukenborg-Colsman; Anas Bouguecha
Journal:  Biomed Eng Online       Date:  2009-04-16       Impact factor: 2.819

10.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.