On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

Julia Orlik1, Alexei Zhurov, John Middleton.   

Abstract

Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and troughs formed on the surface of the coating. The size of the peaks and troughs is very small compared with the macrosize of the implant stem and bone in contact. The study of the bone-stem contact by direct application of the finite element method is prohibitively costly. A two-scale asymptotic homogenisation procedure that takes into account the microgeometry of the interface layer and mechanical properties of bone and the implant material is applied to obtain effective, homogenised contact parameters. These parameters can be used in finite element analyses involving smooth interfaces, which require hundreds of times fewer finite elements. With the homogenisation technique and finite element analyses for a simplified design, two parameters were found to be most important--the normal contact stiffness and the friction coefficient. They both increase several times as bone grows into the rough surface of the implant and mineralises, thus providing a stronger interface and resulting in reduced micromotions.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14630470     DOI: 10.1016/s1350-4533(03)00099-7

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Radiograph-based femur morphing method.

Authors:  E M Zanetti; V Crupi; C Bignardi; P M Calderale
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

2.  All dual mobility cups are not the same.

Authors:  Thierry Aslanian
Journal:  Int Orthop       Date:  2017-01-18       Impact factor: 3.075

3.  Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface.

Authors:  Maria Letizia Raffa; Vu-Hieu Nguyen; Guillaume Haiat
Journal:  Biomed Eng Online       Date:  2019-12-03       Impact factor: 2.819

4.  Comparison of early migration patterns between a ceramic and polyethylene liner in uncemented Trabecular Titanium cups: a 2-year randomized controlled trial of 52 hips using radiostereometric analysis.

Authors:  Amanda D Klaassen; Elisabeth A Schäffer; Nienke W Willigenburg; Loes W A H Van Beers; Vanessa A B Scholtes; Victor P M Van der Hulst; Lennard A Koster; Bart L Kaptein; Dirk Jan F Moojen; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2022-04-28       Impact factor: 3.925

5.  Postoperative development of bone mineral density and muscle strength in the lower limb after cemented and uncemented total hip replacement.

Authors:  Tobias Lindner; Christine Krüger; Cornelius Kasch; Susanne Finze; Wolfram Steens; Wolfram Mittelmeier; Ralf Skripitz
Journal:  Open Orthop J       Date:  2014-09-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.