Literature DB >> 17581730

[Percutaneously navigated balloon fracture reduction in a displaced acetabular fracture].

B König1, C Khodadadyan, A Schäffler, R Pflugmacher, U Stöckle.   

Abstract

Kyphoplasty is a well proven surgical procedure for osteoporotic fractures in spine surgery. Anatomic reconstruction of the joint is the primary aim in the treatment of acetabular fractures. To achieve this, extensive approaches with entry related morbidity are usually needed. Percutaneous stabilisations are still limited for non- or minimally displaced fractures.For displaced acetabular fractures, there are percutaneous procedures described with intraoperative CT control or by the use of a 3D C-arm. The case of an anterior column posterior hemitranverse fracture with an articular step in the weight bearing area is presented. In this case, a kyphoplasty balloon was placed by use of 3D C-arm navigation. After 2D C-arm controlled fracture reduction, the supra-acetabular screw was inserted percutaneously using the previous 3D navigation data set.With the combination of kyphoplasty technique, intraoperative 3D C-arm control and 3D C-arm based navigation, this displaced acetabular fracture could be reduced and fixed percutaneously. Anatomic reconstruction of the joint remains the primary aim.

Entities:  

Mesh:

Year:  2007        PMID: 17581730     DOI: 10.1007/s00113-007-1288-5

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  13 in total

Review 1.  A transverse acetabular nonunion treated with computer-assisted percutaneous internal fixation. A case report.

Authors:  R D Zura; D M Kahler
Journal:  J Bone Joint Surg Am       Date:  2000-02       Impact factor: 5.284

2.  Coronal acetabular fractures: the anterior approach in computed tomography-navigated minimally invasive percutaneous fixation.

Authors:  A L Jacob; N Suhm; A Kaim; P Regazzoni; W Steinbrich; P Messmer
Journal:  Cardiovasc Intervent Radiol       Date:  2000 Sep-Oct       Impact factor: 2.740

3.  Transverse acetabular fracture: hybrid minimal access and percutaneous CT-navigated fixation.

Authors:  Thomas Gross; Augustinus L Jacob; Peter Messmer; Pietro Regazzoni; Wolfgang Steinbrich; Rolf W Huegli
Journal:  AJR Am J Roentgenol       Date:  2004-10       Impact factor: 3.959

4.  Percutaneous screw fixation of acetabular fractures with CT guidance: preliminary results of a new technique.

Authors:  S B Gay; C Sistrom; G J Wang; D A Kahler; T Boman; N McHugh; H T Goitz
Journal:  AJR Am J Roentgenol       Date:  1992-04       Impact factor: 3.959

5.  Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury.

Authors:  J M Matta
Journal:  J Bone Joint Surg Am       Date:  1996-11       Impact factor: 5.284

6.  Displaced anterior column acetabular fracture: closed reduction and percutaneous CT-navigated fixation.

Authors:  R W Huegli; H Staedele; P Messmer; P Regazzoni; W Steinbrich; T Gross
Journal:  Acta Radiol       Date:  2004-10       Impact factor: 1.990

7.  [Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic area].

Authors:  B König; U Erdmenger; R J Schröder; G Wienas; J Schaefer; M Pech; U Stöckle
Journal:  Unfallchirurg       Date:  2005-05       Impact factor: 1.000

8.  Kyphoplasty.

Authors:  K Jonsson
Journal:  Acta Radiol       Date:  2006-05       Impact factor: 1.990

9.  Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum.

Authors:  A J Starr; A L Jones; C M Reinert; D S Borer
Journal:  Injury       Date:  2001-05       Impact factor: 2.586

10.  Closed reduction and percutaneous fixation of anterior column acetabular fractures.

Authors:  Adam C Crowl; David M Kahler
Journal:  Comput Aided Surg       Date:  2002
View more
  3 in total

1.  Balloon osteoplasty--a new technique for reduction and stabilisation of impression fractures in the tibial plateau: a cadaver study and first clinical application.

Authors:  Philipp Ahrens; Gunther Sandmann; Jan Bauer; Benjamin König; Frank Martetschläger; Dirk Müller; Sebastian Siebenlist; Chlodwig Kirchhoff; Markus Neumaier; Peter Biberthaler; Ulrich Stöckle; Thomas Freude
Journal:  Int Orthop       Date:  2012-06-24       Impact factor: 3.075

2.  Arthroscopic-Guided Balloon Tibioplasty in Schatzker III Tibial Plateau Fracture.

Authors:  Fabrizio Cuzzocrea; Eugenio Jannelli; Alessandro Ivone; Simone Perelli; Alberto Fioruzzi; Matteo Ghiara; Giacomo Zanon; Francesco Benazzo
Journal:  Joints       Date:  2019-10-11

Review 3.  Outcomes following balloon tibioplasty versus conventional osteosynthesis techniques for Schatzker type III tibial plateau fractures: a systematic review.

Authors:  Andrew Blankenship; Amy Singleton; Logan Hiatt; Kirk W Evanson; Seth Phillips; Richard Miller
Journal:  J Orthop Surg Res       Date:  2022-04-07       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.