[Introduction of a new mobile C-arm/CT combination equipment (ISO-C-3D). Initial results of 3-D sectional imaging].

C Rock1, U Linsenmaier, R Brandl, D Kotsianos, S Wirth, R Kaltschmidt, E Euler, W Mutschler, K J Pfeifer.   

Abstract

Preclinical evaluation of a new mobile C-arm image amplifier with an option for three-dimensional computed tomography (CT) imaging (prototype Iso-C3D) with respect to high-contrast resolution and possible clinical applications. Cadaveric specimens (n = 30) of different joints of the lower and upper extremities and specimens of the spinal column were examined with the Iso-C3D and evaluated for image quality. In addition, using a high-contrast phantom (Catphan, Phantom Laboratory, Salem, N.Y., USA) and a fracture model of the femoral bone, measurements of high-contrast resolution were performed in comparison to spiral CT. With the exception of the shoulder, all joint regions including the entire spinal column could be examined. Adequate image quality could be achieved in smaller joints such as the wrist, elbow, ankle, and knee, whereas a remarkably decreased image quality was found when imaging the hip as well as the lumbar and thoracic spine. Images of the phantom study and high-contrast fracture model showed a high-contrast resolution comparable to helical CT (9 Lp/cm in xy-axis). In smaller joints, the image quality of the mobile C-arm CT imaging system (Iso-C3D) is comparable to that of helical CT. Image quality in examinations of the hip and lumbar and thoracic spine seems to be sufficient for intraoperative control studies of osteosynthesis. Problems still occur in shoulder examinations.

Entities:  

Mesh:

Year:  2001        PMID: 11572124     DOI: 10.1007/s001130170053

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  17 in total

1.  [Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic area].

Authors:  B König; U Erdmenger; R J Schröder; G Wienas; J Schaefer; M Pech; U Stöckle
Journal:  Unfallchirurg       Date:  2005-05       Impact factor: 1.000

2.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

3.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

4.  [Drilling with 3D fluoroscopic navigation in osteonecrosis of the femoral condyle].

Authors:  M Citak; D Kendoff; T Stübig; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-05       Impact factor: 1.000

5.  [Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens].

Authors:  S Wirth; E Euler; D Kotsianos-Hermle; M Treitl; U Linsenmaier; K-J Pfeifer; M Reiser; W Mutschler
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

6.  Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures.

Authors:  Markus Beck; Thomas Mittlmeier; Philip Gierer; Christoph Harms; Georg Gradl
Journal:  Eur Spine J       Date:  2009-06-10       Impact factor: 3.134

7.  [Hybrid operating room : Application in trauma surgery and orthopaedics].

Authors:  Frederic Braun; Simon Peh; Matthias Weuster; Tim Klueter; Andreas Seekamp; Sebastian Lippross
Journal:  Unfallchirurg       Date:  2020-02       Impact factor: 1.000

8.  Evaluation of Software-Based Metal Artifact Reduction in Intraoperative 3D Imaging of the Spine Using a Mobile Cone Beam CT.

Authors:  Maxim Privalov; Marcus Mohr; Benedict Swartman; Nils Beisemann; Holger Keil; Jochen Franke; Paul Alfred Grützner; Sven Yves Vetter
Journal:  J Digit Imaging       Date:  2020-10       Impact factor: 4.056

9.  [Intraoperative 3D C-arm imaging. State of the art].

Authors:  J von Recum; K Wendl; B Vock; P A Grützner; J Franke
Journal:  Unfallchirurg       Date:  2012-03       Impact factor: 1.000

10.  Early Weight Bearing of Calcaneal Fractures Treated by Intraoperative 3D-Fluoroscopy and Locked-Screw Plate Fixation.

Authors:  B Kienast; J Gille; C Queitsch; M M Kaiser; R Thietje; C Juergens; A P Schulz
Journal:  Open Orthop J       Date:  2009-08-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.