Abstract

Malposition of extraosseous or intra-articular screws, e.g., in osteosyntheses of joint fractures or in the vicinity of joints, frequently remains undiscovered in intraoperative fluoroscopy and is only recognized on postoperative computed tomography (CT) scans. The aim of the study, therefore, was to assess the value of a new mobile C-arm three-dimensional imaging device in comparison with fluoroscopy, conventional radiographs, and CT scans using an extremity model. Screws were inserted ventrally in four anatomic lower leg specimens without talus fractures parallel to the longitudinal axis to simulate surgical management of fractures of the talus. The specimens supplied were examined with fluorscopy, conventional radiography, spiral CT, and the new three-dimensional imaging with the SIREMOBIL Iso-C3D. These four modalities were evaluated by ten radiologists and ten trauma surgeons and were compared regarding subjective image quality and position of the screws. The quality of information acquired with the SIREMOBIL Iso-C3D was equal to that of the CT examinations, although image quality was considered inferior to fluoroscopy, conventional radiography, and CT (p < 0.001). In contrast to the previous procedure with intraoperative fluoroscopy and subsequent postoperative X-ray control, the results obtained with the SIREMOBIL IsoC3D were superior. The SIREMOBIL Iso-C3D is useful for the intraoperative diagnosis of small joints with few artifacts producing osteosynthesis material, i.e., for recognizing the position of screws in the region of glenoid surfaces.

Entities:  

Mesh:

Year:  2001        PMID: 11572126     DOI: 10.1007/s001130170055

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  16 in total

1.  [Intraoperative imaging with the ISO C(3D)].

Authors:  M Wich; N Spranger; A Ekkernkamp
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

2.  [Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic area].

Authors:  B König; U Erdmenger; R J Schröder; G Wienas; J Schaefer; M Pech; U Stöckle
Journal:  Unfallchirurg       Date:  2005-05       Impact factor: 1.000

3.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

4.  [Cost-benefit analysis of intraoperative 3D imaging].

Authors:  T Hüfner; T Stübig; T Gösling; D Kendoff; J Geerling; C Krettek
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

5.  [Integrated navigation. Preclinical evaluation and initial clinical experience].

Authors:  U Stöckle; A Schäffler; B König; N P Haas
Journal:  Unfallchirurg       Date:  2006-11       Impact factor: 1.000

6.  [The clinical use of the ISO-C(3D) imaging system in calcaneus fracture surgery].

Authors:  A Rübberdt; R Feil; D Stengel; N Spranger; S Mutze; M Wich; A Ekkernkamp
Journal:  Unfallchirurg       Date:  2006-02       Impact factor: 1.000

7.  [Drilling with 3D fluoroscopic navigation in osteonecrosis of the femoral condyle].

Authors:  M Citak; D Kendoff; T Stübig; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-05       Impact factor: 1.000

8.  Computer aided surgery in foot and ankle: applications and perspectives.

Authors:  Martinus Richter
Journal:  Int Orthop       Date:  2013-05-25       Impact factor: 3.075

9.  [Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens].

Authors:  S Wirth; E Euler; D Kotsianos-Hermle; M Treitl; U Linsenmaier; K-J Pfeifer; M Reiser; W Mutschler
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

10.  Early Weight Bearing of Calcaneal Fractures Treated by Intraoperative 3D-Fluoroscopy and Locked-Screw Plate Fixation.

Authors:  B Kienast; J Gille; C Queitsch; M M Kaiser; R Thietje; C Juergens; A P Schulz
Journal:  Open Orthop J       Date:  2009-08-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.