Literature DB >> 11898078

[Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D)].

C Rock1, D Kotsianos, U Linsenmaier, T Fischer, R Brandl, F Vill, S Wirth, R Kaltschmidt, E Euler, K J Pfeifer, M Reiser.   

Abstract

PURPOSE: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier.
MATERIAL AND METHODS: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3D). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories).
RESULTS: Adequate image quality (mean score values 3 - 4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2 - 3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm).
CONCLUSION: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures.

Entities:  

Mesh:

Year:  2002        PMID: 11898078     DOI: 10.1055/s-2002-20107

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  24 in total

1.  [Diagnostics at the wrist].

Authors:  R Meier; C Krettek; H Krimmer
Journal:  Unfallchirurg       Date:  2003-12       Impact factor: 1.000

2.  Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study.

Authors:  Marcus Christian Müller; Peter Belei; Peter H Pennekamp; Koroush Kabir; Dieter C Wirtz; Christof Burger; Oliver Weber
Journal:  Int Orthop       Date:  2012-02-23       Impact factor: 3.075

3.  [Radiological procedures in the traumatised wrist].

Authors:  R Meier; H Jansen; M Uhl
Journal:  Orthopade       Date:  2010-08       Impact factor: 1.087

4.  [Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery].

Authors:  U Stöckle; B König; A Schäffler; T Zschernack; N P Haas
Journal:  Unfallchirurg       Date:  2006-01       Impact factor: 1.000

5.  [Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic area].

Authors:  B König; U Erdmenger; R J Schröder; G Wienas; J Schaefer; M Pech; U Stöckle
Journal:  Unfallchirurg       Date:  2005-05       Impact factor: 1.000

6.  Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Authors:  D Briem; W Linhart; W Lehmann; P G Begemann; G Adam; U Schumacher; D M Cullinane; J M Rueger; J Windolf
Journal:  Eur Spine J       Date:  2005-07-12       Impact factor: 3.134

7.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

8.  [Intraoperative three-dimensional imaging to monitor selective decompression in lumbar spinal stenosis].

Authors:  U M Mauer; U Kunz
Journal:  Orthopade       Date:  2006-12       Impact factor: 1.087

9.  [The clinical use of the ISO-C(3D) imaging system in calcaneus fracture surgery].

Authors:  A Rübberdt; R Feil; D Stengel; N Spranger; S Mutze; M Wich; A Ekkernkamp
Journal:  Unfallchirurg       Date:  2006-02       Impact factor: 1.000

10.  [Navigation for placement of scaphoid screws : a new indication for intraoperative 3D navigation-a cadaver study].

Authors:  D Kendoff; M Citak; R Gaulke; M J Gardner; J Geerling; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2007-09       Impact factor: 1.000