Literature DB >> 19885312

Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT.

Weiwei Qi1, Jianying Li, Xiangke Du.   

Abstract

OBJECTIVE: To evaluate a quantitative method for individually adjusting the tube current to obtain images with consistent noise in electrocardiogram (ECG)-gated CT cardiac scans.
MATERIALS AND METHODS: The image noise from timing bolus and cardiac CT scans of 80 patients (Group A) who underwent a 64-row multidetector (MD) CT cardiac examination with patient-independent scan parameters were analyzed. A formula was established using the noise correlation between the timing bolus and cardiac scans. This formula was used to predict the required tube current to obtain the desired cardiac CT image noise based on the timing bolus noise measurement. Subsequently, 80 additional cardiac patients (Group B) were scanned with individually adjusted tube currents using an established formula to evaluate its ability to obtain accurate and consistent image noise across the patient population. Image quality was evaluated using score scale of 1 to 5 with a score of 3 or higher being clinically acceptable.
RESULTS: Using the formula, we obtained an average CT image noise of 28.55 Hounsfield unit (HU), with a standard deviation of only 1.7 HU, as opposed to a target value of 28 HU. Image quality scores were 4.03 and 4.27 for images in Groups A and B, respectively, and there was no statistical difference between the image quality scores between the two groups. However, the average CT dose index (CTDIvol) was 30% lower for Group B.
CONCLUSION: Adjusting the tube current based on timing bolus scans may provide a consistent image quality and dose optimization for cardiac patients of various body mass index values.

Entities:  

Keywords:  Automatic tube current modulation; Computed tomography (CT); Consistent image quality; Coronary artery imaging; Dose reduction and optimization

Mesh:

Year:  2009        PMID: 19885312      PMCID: PMC2770833          DOI: 10.3348/kjr.2009.10.6.568

Source DB:  PubMed          Journal:  Korean J Radiol        ISSN: 1229-6929            Impact factor:   3.500


  16 in total

1.  Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation.

Authors:  Tobias F Jakobs; Christoph R Becker; Bernd Ohnesorge; Thomas Flohr; Christoph Suess; Uwe J Schoepf; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2002-02-21       Impact factor: 5.315

Review 2.  CT and computed radiography: the pictures are great, but is the radiation dose greater than required?

Authors:  Thomas L Slovis
Journal:  AJR Am J Roentgenol       Date:  2002-07       Impact factor: 3.959

3.  A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT.

Authors:  M Vembar; M J Garcia; D J Heuscher; R Haberl; D Matthews; G E Böhme; N L Greenberg
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

Review 4.  Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography.

Authors:  Hyun Seok Choi; Byoung Wook Choi; Kyu Ok Choe; Donghoon Choi; Kyung-Jong Yoo; Myoung-In Kim; Jinna Kim
Journal:  Radiographics       Date:  2004 May-Jun       Impact factor: 5.333

5.  Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations.

Authors:  Marco Das; Andreas Horst Mahnken; Georg Mühlenbruch; Achim Stargardt; Claudia Weiss; Dirk-Alexander Sennst; Thomas G Flohr; Rolf W Günther; Joachim Ernst Wildberger
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

6.  Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography.

Authors:  Jiang Hsieh; John Londt; Melissa Vass; Jay Li; Xiangyang Tang; Darin Okerlund
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

Review 7.  CT dose reduction and dose management tools: overview of available options.

Authors:  Cynthia H McCollough; Michael R Bruesewitz; James M Kofler
Journal:  Radiographics       Date:  2006 Mar-Apr       Impact factor: 5.333

8.  Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis.

Authors:  Stefania Rizzo; Mannudeep Kalra; Bernhard Schmidt; Tejas Dalal; Christoph Suess; Thomas Flohr; Michael Blake; Sanjay Saini
Journal:  AJR Am J Roentgenol       Date:  2006-03       Impact factor: 3.959

Review 9.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

10.  Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography.

Authors:  Gham Hur; Seong Wan Hong; Su Young Kim; Yong Hoon Kim; Yoon Joon Hwang; Won Ro Lee; Soon Joo Cha
Journal:  AJR Am J Roentgenol       Date:  2007-07       Impact factor: 3.959

View more
  10 in total

1.  Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction.

Authors:  So Won Lee; Yookyung Kim; Sung Shine Shim; Jeong Kyong Lee; Seok Jeong Lee; Yon Ju Ryu; Jung Hyun Chang
Journal:  Eur Radiol       Date:  2014-01-18       Impact factor: 5.315

2.  Prospective ECG-triggered coronary CT angiography: clinical value of noise-based tube current reduction method with iterative reconstruction.

Authors:  Junlin Shen; Xiangying Du; Daode Guo; Lizhen Cao; Yan Gao; Qi Yang; Pengyu Li; Jiabin Liu; Kuncheng Li
Journal:  PLoS One       Date:  2013-05-31       Impact factor: 3.240

Review 3.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

4.  Radiology residents' awareness about ionizing radiation doses in imaging studies and their cancer risk during radiological examinations.

Authors:  Senem Divrik Gökçe; Erkan Gökçe; Melek Coşkun
Journal:  Korean J Radiol       Date:  2012-03-07       Impact factor: 3.500

5.  Fat volume measurements as a predictor of image noise in coronary computed tomography angiography.

Authors:  Rami M Abazid; Osama A Smettei; Ahmad Almeman; Sawsan Sayed; Hanaa Alsaqqa; Salma M Abdelmageed; Fahad J Alharbi; Abdullah M Alhabib; Mouaz H Al-Mallah
Journal:  J Saudi Heart Assoc       Date:  2018-11-17

6.  Prospectively electrocardiogram-gated high-pitch spiral acquisition mode dual-source CT coronary angiography in patients with high heart rates: comparison with retrospective electrocardiogram-gated spiral acquisition mode.

Authors:  Kai Sun; Rui-Juan Han; Li-Jun Ma; Li-Jun Wang; Li-Gang Li; Jiu-Hong Chen
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

7.  Improving spatial adaptivity of nonlocal means in low-dosed CT imaging using pointwise fractal dimension.

Authors:  Xiuqing Zheng; Zhiwu Liao; Shaoxiang Hu; Ming Li; Jiliu Zhou
Journal:  Comput Math Methods Med       Date:  2013-03-31       Impact factor: 2.238

8.  Regularized multidirections and multiscales anisotropic diffusion for sinogram restoration of low-dosed computed tomography.

Authors:  Zhiwu Liao
Journal:  Comput Math Methods Med       Date:  2013-11-21       Impact factor: 2.238

9.  Radiation dose reduction via sinogram affirmed iterative reconstruction and automatic tube voltage modulation (CARE kV) in abdominal CT.

Authors:  Hyun Joo Shin; Yong Eun Chung; Young Han Lee; Jin-Young Choi; Mi-Suk Park; Myeong-Jin Kim; Ki Whang Kim
Journal:  Korean J Radiol       Date:  2013-11-05       Impact factor: 3.500

10.  A practical approach for a patient-tailored dose protocol in coronary CT angiography using prospective ECG triggering.

Authors:  J D van Dijk; E D Huizing; P L Jager; J P Ottervanger; S Knollema; C H Slump; J A van Dalen
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-12       Impact factor: 2.357

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.