Literature DB >> 20852938

Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring.

Zilai Pan1, Lifang Pang, Jianying Li, Huan Zhang, Wenjie Yang, Bei Ding, Weimin Chai, Kemin Chen, Weiwu Yao.   

Abstract

To evaluate the clinical value of a body mass index (BMI) based tube current (mA) selection method for obtaining consistent image quality with dose optimization in MDCT prospective ECG gated coronary calcium scoring. A formula for selecting mA to achieve desired image quality based on patient BMI was established using a control group (A) of 200 MDCT cardiac patients with a standard scan protocol. One hundred patients in Group B were scanned with this BMI-dependent mA for achieving a desired noise level of 18 HU at 2.5 mm slice thickness. The CTDIvol and image noise on the ascending aorta for the two groups were recorded. Two experienced radiologists quantitatively evaluated the image quality using scores of 1-4 with 4 being the highest. The image quality scores had no statistical difference (P = 0.71) at 3.89 ± 0.32, 3.87 ± 0.34, respectively, for groups A and B of similar BMI. The image noise in Group A had linear relationship with BMI. The image noise in Group B using BMI-dependent mA was independent of BMI with average value of 17.9 HU and smaller deviations for the noise values than in Group A (2.0 vs. 2.9 HU). There was a 35% dose reduction with BMI-dependent mA selection method on average with the lowest effective dose being only 0.35 mSv for patient with BMI of 18.3. A quantitative BMI-based mA selection method in MDCT prospective ECG gated coronary calcium scoring has been proposed to obtain a desired and consistent image quality and provide dose optimization across patient population.

Entities:  

Mesh:

Year:  2010        PMID: 20852938     DOI: 10.1007/s10554-010-9701-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

1.  Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations.

Authors:  Marco Das; Andreas Horst Mahnken; Georg Mühlenbruch; Achim Stargardt; Claudia Weiss; Dirk-Alexander Sennst; Thomas G Flohr; Rolf W Günther; Joachim Ernst Wildberger
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

2.  Effect of dose-reduced scan protocols on cardiac coronary image quality with 64-row MDCT: a cardiac phantom study.

Authors:  Xiaolu Fei; Xiangying Du; Pengyu Li; Jingmin Liao; Yun Shen; Kuncheng Li
Journal:  Eur J Radiol       Date:  2007-08-31       Impact factor: 3.528

Review 3.  Emerging epidemic of cardiovascular disease in developing countries.

Authors:  K S Reddy; S Yusuf
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

4.  Individualized tube current selection for 64-row cardiac CTA based on analysis of the scout view.

Authors:  Jianhua Gao; Jianying Li; James Earls; Tao Li; Quisheng Wang; Ruping Dai
Journal:  Eur J Radiol       Date:  2010-05-20       Impact factor: 3.528

5.  Incidence and significance of coronary artery calcification.

Authors:  J H McCarthy; F J Palmer
Journal:  Br Heart J       Date:  1974-05

6.  Correlation of coronary calcification and angiographically documented stenoses in patients with suspected coronary artery disease: results of 1,764 patients.

Authors:  R Haberl; A Becker; A Leber; A Knez; C Becker; C Lang; R Brüning; M Reiser; G Steinbeck
Journal:  J Am Coll Cardiol       Date:  2001-02       Impact factor: 24.094

7.  Coronary artery calcium evaluation by electron beam computed tomography and its relation to new cardiovascular events.

Authors:  N D Wong; J C Hsu; R C Detrano; G Diamond; H Eisenberg; J M Gardin
Journal:  Am J Cardiol       Date:  2000-09-01       Impact factor: 2.778

8.  Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol.

Authors:  A H Mahnken; J E Wildberger; J Simon; R Koos; T G Flohr; S Schaller; R W Günther
Journal:  AJR Am J Roentgenol       Date:  2003-08       Impact factor: 3.959

Review 9.  The "post-64" era of coronary CT angiography: understanding new technology from physical principles.

Authors:  Hansel J Otero; Michael L Steigner; Frank J Rybicki
Journal:  Radiol Clin North Am       Date:  2009-01       Impact factor: 2.303

Review 10.  Expert review on coronary calcium.

Authors:  Matthew J Budoff; Khawar M Gul
Journal:  Vasc Health Risk Manag       Date:  2008
View more
  2 in total

Review 1.  Coronary artery calcium scoring and its impact on the clinical practice in the era of multidetector CT.

Authors:  Jongmin Lee
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-20       Impact factor: 2.357

Review 2.  Coronary artery calcium score: a review.

Authors:  Abbas Arjmand Shabestari
Journal:  Iran Red Crescent Med J       Date:  2013-12-05       Impact factor: 0.611

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.