Literature DB >> 15806366

Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT.

Jessen Gurung1, M Fawad Khan, Adel Maataoui, C Herzog, R Bux, H Bratzke, Hanns Ackermann, Thomas J Vogl.   

Abstract

To optimize examination protocols of 16-row multi-detector CT (MDCT) of pelvis for dose reduction with regard to image quality. MDCT of pelvis was performed on 12 cadaver specimens with stepwise reduction of tube current from 160 mA (113, 80, 56, 40, 28) to 20 mA at 120 kV. Scan parameters were 16 x 1.5 mm collimation. Reconstructions of axial and coronal images were used for evaluation of cortex, trabeculum, image quality, image noise, acetabulum and iliosacral (ISJ) joints. After data were blinded, evaluation of images was done by three radiologists according to 5-point Likert scale. Accuracy of the observers in sorting films according to dose reduction was determined with kappa coefficient. Mean values of image evaluation were determined. Pronounced deterioration of image quality for all criteria was observed between 80 and 28 mA. Adequate image quality was obtained at 40 mA [effective dose (E): 2.2 mSv, CTDI(w): 2.8 mGy] for criterion detailed definition of acetabulum and ISJ and at 80 mA (E: 4.4 mSv, CTDI(w): 5.6 mGy) for remaining criteria. Moderate agreement was observed between the three observers (kappa coefficient: 0.31). All observers were excellent in arranging images according to decreasing dose. Using 16-row MDCT image quality of pelvis is acceptable at 80 mA and 120 kV. This translates into a dose reduction of 33% of average value of the nationwide survey of the German Roentgen Society (1999) for this type of examination.

Mesh:

Year:  2005        PMID: 15806366     DOI: 10.1007/s00330-005-2720-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  16 in total

1.  Pulmonary nodules: experimental and clinical studies at low-dose CT.

Authors:  S Diederich; H Lenzen; R Windmann; Z Puskas; T M Yelbuz; S Henneken; T Klaiber; M Eameri; N Roos; P E Peters
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

2.  [Radiation exposure of the head, midface and pelvis in multi-slice CT (MSCT): comparison with single-slice CT (SSCT)].

Authors:  U Wedegärtner; H Thurmann; R Schmidt; G Adam
Journal:  Rofo       Date:  2003-02

3.  [Multislice CT of the pelvis: dose reduction with regard to image quality].

Authors:  U Wedegärtner; M Lorenzen; J Lorenzen; C Nolte-Ernsting; C Weber; C Dieckmann; M Cramer; V Schoder; G Adam
Journal:  Rofo       Date:  2004-01

4.  Management of patient dose and image noise in routine pediatric CT abdominal examinations.

Authors:  Francis R Verdun; D Lepori; Pascal Monnin; Jean-François Valley; Pierre Schnyder; F Gudinchet
Journal:  Eur Radiol       Date:  2004-01-13       Impact factor: 5.315

5.  Pulmonary nodule detection: low-dose versus conventional CT.

Authors:  H Rusinek; D P Naidich; G McGuinness; B S Leitman; D I McCauley; G A Krinsky; K Clayton; H Cohen
Journal:  Radiology       Date:  1998-10       Impact factor: 11.105

6.  Radiation exposure and image quality in chest CT examinations.

Authors:  J G Ravenel; E M Scalzetti; W Huda; W Garrisi
Journal:  AJR Am J Roentgenol       Date:  2001-08       Impact factor: 3.959

7.  Radiation dose reduction in CT of the pediatric pelvis.

Authors:  I R Kamel; R J Hernandez; J E Martin; A E Schlesinger; L T Niklason; K E Guire
Journal:  Radiology       Date:  1994-03       Impact factor: 11.105

8.  [The role of CT in diagnosis and therapy of fractures of the pelvic girdle].

Authors:  P M Rommens; J Gielen; P L Broos
Journal:  Unfallchirurg       Date:  1992-04       Impact factor: 1.000

9.  CT of sacral injury.

Authors:  M A Montana; M L Richardson; R F Kilcoyne; J D Harley; W P Shuman; L A Mack
Journal:  Radiology       Date:  1986-11       Impact factor: 11.105

10.  Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique.

Authors:  Ulrich Baum; Katharina Anders; Gregor Steinbichler; Michael Lell; Holger Greess; Thomas Riedel; Marc Kachelriess; Willi A Kalender; Werner A Bautz
Journal:  Eur Radiol       Date:  2004-08-24       Impact factor: 5.315

View more
  13 in total

1.  Cone beam CT dose reduction in prostate radiotherapy using Likert scale methods.

Authors:  Keith A Langmack; Louise A Newton; Suzanne Jordan; Ruth Smith
Journal:  Br J Radiol       Date:  2015-12-21       Impact factor: 3.039

2.  A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation.

Authors:  Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Yoshiharu Nakayama; Da Liu; Taiga Goto; Yasuyuki Yamashita; Shinichi Hori
Journal:  Eur Radiol       Date:  2005-10-20       Impact factor: 5.315

3.  Impact of the introduction of 16-row MDCT on image quality and patient dose: Phantom study and multi-centre survey.

Authors:  Francis R Verdun; Nicolas Theumann; Pierre-Alexandre Poletti; Daniel Gutierrez; Abbas Aroua; Pierre Schnyder; Jean-François Valley; Salah D Qanadli
Journal:  Eur Radiol       Date:  2006-08-29       Impact factor: 5.315

Review 4.  CT of the musculoskeletal system: what is left is the days of MRI?

Authors:  A T H West; T J Marshall; P W Bearcroft
Journal:  Eur Radiol       Date:  2008-08-09       Impact factor: 5.315

5.  Optimizing radiation dose parameters in MDCT arthrography of the shoulder: illustration of basic concepts in a cadaveric study.

Authors:  Julien Aguet; Fabio Becce; Vincent Dunet; Alain Vlassenbroek; Emmanuel E Coche; Patrick Omoumi
Journal:  Skeletal Radiol       Date:  2019-02-06       Impact factor: 2.199

6.  Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans.

Authors:  Simon Veldhoen; Maximilian Schöllchen; H Hanken; C Precht; F O Henes; G Schön; H D Nagel; U Schumacher; M Heiland; G Adam; M Regier
Journal:  Eur Radiol       Date:  2016-05-11       Impact factor: 5.315

7.  Interrater reliability and radiation dosage of oblique coronal computed tomography for sacroiliitis in comparison with axial computed tomography.

Authors:  Sheng-Guang Li; Xiangyuan Liu; Huiqiong Zhou; Qing Zhang
Journal:  Br J Radiol       Date:  2017-11-03       Impact factor: 3.039

8.  Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model.

Authors:  Joern Kemper; Marc Regier; Paul M Bansmann; Philipp G C Begemann; Alexander Stork; Hans Dieter Nagel; Gerhard Adam; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-14       Impact factor: 5.315

9.  Dosimetric characteristics of a 16-slice computed tomography scanner.

Authors:  Nicholas Theocharopoulos; Kostas Perisinakis; John Damilakis; Spyros Karampekios; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 7.034

Review 10.  Should low-dose computed tomography kidneys, ureter and bladder be the new investigation of choice in suspected renal colic?: A systematic review.

Authors:  Tamsin Drake; Nitin Jain; Timothy Bryant; Iain Wilson; Bhaskar K Somani
Journal:  Indian J Urol       Date:  2014-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.