Literature DB >> 9769838

Pulmonary nodule detection: low-dose versus conventional CT.

H Rusinek1, D P Naidich, G McGuinness, B S Leitman, D I McCauley, G A Krinsky, K Clayton, H Cohen.   

Abstract

PURPOSE: To quantitate the effectiveness of low-dose computed tomography (CT) in the identification of pulmonary nodules while controlling for anatomic nodule characteristics and to establish what factors lead to reduced diagnostic sensitivity at low-dose CT.
MATERIALS AND METHODS: Each of six participating radiologist independently rated 200 image panels by using a four-point confidence scale. Conventional images were obtained at 200 mAs; low-dose images were obtained at 20 mAs. To fully control their characteristics, nodules were simulated with a given diameter, shape, and section thickness while preserving the resolution, noise level, and reconstruction artifacts of the original images. Panels were matched so that nodules on low-dose and conventional images had equivalent sizes, locations, and relationships to blood vessels.
RESULTS: Among 864 positive panels, 259 (60%) of 432 low-dose panels and 272 (63%) of 432 conventional panels were correctly interpreted (P = .259). Lowering the x-ray dose significantly reduced the detectability of peripheral nodules (P = .019) and nodules separated from blood vessels (P = .044). Surprisingly, 3-mm nodules were detected with approximately equal sensitivity (P = .181) at conventional and low-dose CT. The specificity of low-dose images was 88% (148 of 168 panels) versus 91% (153 of 168 panels) for conventional images (P = .372).
CONCLUSION: Low-dose CT is acceptable for pulmonary nodule identification, making it suitable for primary screening. These results confirm the strong effect of size, location, and angiocentricity on the sensitivity of nodule detection with conventional CT.

Mesh:

Year:  1998        PMID: 9769838     DOI: 10.1148/radiology.209.1.9769838

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  30 in total

1.  Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

Authors:  Jens Ricke; Frank Fischbach; Torsten Freund; Ulf Teichgräber; Enrique Lopez Hänninen; Rainer Röttgen; Ulrike Engert; Hermann Eichstädt; Roland Felix
Journal:  Eur Radiol       Date:  2003-06-19       Impact factor: 5.315

2.  Solitary pulmonary nodule: detection and management.

Authors:  S Diederich; M Das
Journal:  Cancer Imaging       Date:  2006-10-31       Impact factor: 3.909

3.  Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT.

Authors:  Dag Wormanns; Karl Ludwig; Florian Beyer; Walter Heindel; Stefan Diederich
Journal:  Eur Radiol       Date:  2004-11-04       Impact factor: 5.315

4.  Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT.

Authors:  Jessen Gurung; M Fawad Khan; Adel Maataoui; C Herzog; R Bux; H Bratzke; Hanns Ackermann; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

5.  Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT.

Authors:  J C M van de Wiel; Y Wang; D M Xu; H J van der Zaag-Loonen; E J van der Jagt; R J van Klaveren; M Oudkerk
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

6.  L0 constrained sparse reconstruction for multi-slice helical CT reconstruction.

Authors:  Yining Hu; Lizhe Xie; Limin Luo; Jean Claude Nunes; Christine Toumoulin
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

Review 7.  Oligonucleotide-based theranostic nanoparticles in cancer therapy.

Authors:  Reza Shahbazi; Bulent Ozpolat; Kezban Ulubayram
Journal:  Nanomedicine (Lond)       Date:  2016-04-22       Impact factor: 5.307

8.  Computer-aided diagnosis systems for lung cancer: challenges and methodologies.

Authors:  Ayman El-Baz; Garth M Beache; Georgy Gimel'farb; Kenji Suzuki; Kazunori Okada; Ahmed Elnakib; Ahmed Soliman; Behnoush Abdollahi
Journal:  Int J Biomed Imaging       Date:  2013-01-29

9.  Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection.

Authors:  Ji Young Lee; Myung Jin Chung; Chin A Yi; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500

10.  Lung cancer screening with low-dose helical CT in Korea: experiences at the Samsung Medical Center.

Authors:  Semin Chong; Kyung Soo Lee; Myung Jin Chung; Tae Sung Kim; Hojoong Kim; O Jung Kwon; Yoon-Ho Choi; Chong H Rhee
Journal:  J Korean Med Sci       Date:  2005-06       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.