Literature DB >> 10540674

Pulmonary nodules: experimental and clinical studies at low-dose CT.

S Diederich1, H Lenzen, R Windmann, Z Puskas, T M Yelbuz, S Henneken, T Klaiber, M Eameri, N Roos, P E Peters.   

Abstract

PURPOSE: To compare the number of pulmonary nodules detected at helical low- and standard-dose computed tomography (CT) and to investigate the diagnostic value of low-dose CT with a radiation exposure equivalent to that used at chest radiography.
MATERIALS AND METHODS: Two radiologists recorded pulmonary nodules at standard-dose (250 or 100 mA, pitch of 1; 200 mA, pitch of 2) or low-dose CT (50 or 25 mA, pitch of 1 or 2) in five postmortem specimens and 75 patients. Nodules were assessed by size (5 mm or smaller, 6-10 mm, or larger than 10 mm) and by diagnostic confidence ("definite nodule," "definite lesion, not classic nodule," or "questionable lesion, possibly representing a vessel") with the Wilcoxon signed rank test. Artifacts depicted at low-dose CT were recorded.
RESULTS: There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT except in nodules 5 mm or smaller that were assessed as definite nodules at standard- or low-dose CT (25 mA, pitch of 2) (472 vs 397, P < .05). Artifacts that possibly interfered with nodule detection were observed exclusively at CT with 25 mA and a pitch of 2.
CONCLUSION: Pulmonary nodules were detected reliably at CT with 50 mA and pitch of 2 or with 25 mA and a pitch of 1. However, further reduction of the dose to that used at chest radiography was associated with a significant decrease in the number of nodules 5 mm or smaller that were detected, possibly due to artifacts.

Entities:  

Mesh:

Year:  1999        PMID: 10540674     DOI: 10.1148/radiology.213.1.r99oc29289

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  25 in total

1.  Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

Authors:  Jens Ricke; Frank Fischbach; Torsten Freund; Ulf Teichgräber; Enrique Lopez Hänninen; Rainer Röttgen; Ulrike Engert; Hermann Eichstädt; Roland Felix
Journal:  Eur Radiol       Date:  2003-06-19       Impact factor: 5.315

Review 2.  Multislice CT: update on radiation and screening.

Authors:  Mannudeep K Kalra; Michael M Maher; Sanjay Saini
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

3.  Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

Authors:  Maninderpal Kaur Gill; Anushya Vijayananthan; Gnana Kumar; Kasthoori Jayarani; Kwan-Hoong Ng; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2015-08

4.  Solitary pulmonary nodule: detection and management.

Authors:  S Diederich; M Das
Journal:  Cancer Imaging       Date:  2006-10-31       Impact factor: 3.909

5.  Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT.

Authors:  Dag Wormanns; Karl Ludwig; Florian Beyer; Walter Heindel; Stefan Diederich
Journal:  Eur Radiol       Date:  2004-11-04       Impact factor: 5.315

6.  Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT.

Authors:  Jessen Gurung; M Fawad Khan; Adel Maataoui; C Herzog; R Bux; H Bratzke; Hanns Ackermann; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

Review 7.  Management of an incidentally discovered pulmonary nodule.

Authors:  Catherine Beigelman-Aubry; Catherine Hill; Philippe A Grenier
Journal:  Eur Radiol       Date:  2006-10-05       Impact factor: 5.315

8.  Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT.

Authors:  J C M van de Wiel; Y Wang; D M Xu; H J van der Zaag-Loonen; E J van der Jagt; R J van Klaveren; M Oudkerk
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

9.  CT dose and image quality in the last three scanner generations.

Authors:  Andreas Christe; Johannes Heverhagen; Christoph Ozdoba; Christian Weisstanner; Stefan Ulzheimer; Lukas Ebner
Journal:  World J Radiol       Date:  2013-11-28

Review 10.  Screening for lung cancer with low-dose computed tomography: a review of current status.

Authors:  Henry M Marshall; Rayleen V Bowman; Ian A Yang; Kwun M Fong; Christine D Berg
Journal:  J Thorac Dis       Date:  2013-10       Impact factor: 2.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.