PURPOSE: To compare the number of pulmonary nodules detected at helical low- and standard-dose computed tomography (CT) and to investigate the diagnostic value of low-dose CT with a radiation exposure equivalent to that used at chest radiography. MATERIALS AND METHODS: Two radiologists recorded pulmonary nodules at standard-dose (250 or 100 mA, pitch of 1; 200 mA, pitch of 2) or low-dose CT (50 or 25 mA, pitch of 1 or 2) in five postmortem specimens and 75 patients. Nodules were assessed by size (5 mm or smaller, 6-10 mm, or larger than 10 mm) and by diagnostic confidence ("definite nodule," "definite lesion, not classic nodule," or "questionable lesion, possibly representing a vessel") with the Wilcoxon signed rank test. Artifacts depicted at low-dose CT were recorded. RESULTS: There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT except in nodules 5 mm or smaller that were assessed as definite nodules at standard- or low-dose CT (25 mA, pitch of 2) (472 vs 397, P < .05). Artifacts that possibly interfered with nodule detection were observed exclusively at CT with 25 mA and a pitch of 2. CONCLUSION: Pulmonary nodules were detected reliably at CT with 50 mA and pitch of 2 or with 25 mA and a pitch of 1. However, further reduction of the dose to that used at chest radiography was associated with a significant decrease in the number of nodules 5 mm or smaller that were detected, possibly due to artifacts.
PURPOSE: To compare the number of pulmonary nodules detected at helical low- and standard-dose computed tomography (CT) and to investigate the diagnostic value of low-dose CT with a radiation exposure equivalent to that used at chest radiography. MATERIALS AND METHODS: Two radiologists recorded pulmonary nodules at standard-dose (250 or 100 mA, pitch of 1; 200 mA, pitch of 2) or low-dose CT (50 or 25 mA, pitch of 1 or 2) in five postmortem specimens and 75 patients. Nodules were assessed by size (5 mm or smaller, 6-10 mm, or larger than 10 mm) and by diagnostic confidence ("definite nodule," "definite lesion, not classic nodule," or "questionable lesion, possibly representing a vessel") with the Wilcoxon signed rank test. Artifacts depicted at low-dose CT were recorded. RESULTS: There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT except in nodules 5 mm or smaller that were assessed as definite nodules at standard- or low-dose CT (25 mA, pitch of 2) (472 vs 397, P < .05). Artifacts that possibly interfered with nodule detection were observed exclusively at CT with 25 mA and a pitch of 2. CONCLUSION: Pulmonary nodules were detected reliably at CT with 50 mA and pitch of 2 or with 25 mA and a pitch of 1. However, further reduction of the dose to that used at chest radiography was associated with a significant decrease in the number of nodules 5 mm or smaller that were detected, possibly due to artifacts.
Authors: J C M van de Wiel; Y Wang; D M Xu; H J van der Zaag-Loonen; E J van der Jagt; R J van Klaveren; M Oudkerk Journal: Eur Radiol Date: 2007-01-06 Impact factor: 5.315
Authors: Andreas Christe; Johannes Heverhagen; Christoph Ozdoba; Christian Weisstanner; Stefan Ulzheimer; Lukas Ebner Journal: World J Radiol Date: 2013-11-28