Literature DB >> 21491155

Measurement of leg length discrepancy after total hip arthroplasty. The reliability of a plain radiographic method compared to CT-scanogram.

Martin Kjellberg1, Bariq Al-Amiry, Erling Englund, Göran O Sjödén, Arkan S Sayed-Noor.   

Abstract

OBJECTIVE: To measure the interobserver reliability and intraobserver reproducibility of post total hip arthroplasty (THA) leg length discrepancy (LLD) measurement on radiographs as well as to evaluate its accuracy by comparing it with LLD measurement on computed tomographic scanogram (CT-scanogram).
MATERIALS AND METHODS: In this prospective study, postoperative LLD measurements in ten THA patients were made by four observers on anteroposterior radiographs of the pelvis (inter-teardrop line to the tip of lesser trochanter) and compared to LLD measurements made on CT-scanogram scout views of the lower limb. Two observers repeated the LLD measurements on radiographs 8 weeks after the first measurements. The interobserver reliability of the LLD measurement on plain radiographs was evaluated by comparing the measurements of the four observers and the intraobserver reproducibility by comparing the two repeated measurements made by the two observers.
RESULTS: We found excellent interobserver reliability (mean ICC 0.83) and intraobserver reproducibility (ICC 0.90 and 0.88) of the LLD measurements on plain radiographs. There was a moderate to excellent agreement, but with wide variation of measurements among the four observers, when plain radiographic measurement was compared with CT-scanogram (ICC 0.58, 0.60, 0.71, and 0.82).
CONCLUSION: Despite the excellent interobserver reliability and intraobserver reproducibility of LLD measurement on radiographs, clinicians should be aware of its limited accuracy when compared to CT-scanogram.

Entities:  

Mesh:

Year:  2011        PMID: 21491155     DOI: 10.1007/s00256-011-1166-7

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  23 in total

1.  Results of a method of leg-length equalization for patients undergoing primary total hip replacement.

Authors:  S T Woolson; J M Hartford; A Sawyer
Journal:  J Arthroplasty       Date:  1999-02       Impact factor: 4.757

2.  Reliability and accuracy of MRI scanogram in the evaluation of limb length discrepancy.

Authors:  Anne H Leitzes; Hollis G Potter; Terry Amaral; Robert G Marx; Stephen Lyman; Roger F Widmann
Journal:  J Pediatr Orthop       Date:  2005 Nov-Dec       Impact factor: 2.324

3.  Intertester reliability of the cervical range of motion device.

Authors:  W Rheault; B Albright; C Beyers; M Franta; A Johnson; M Skowronek; J Dougherty
Journal:  J Orthop Sports Phys Ther       Date:  1992       Impact factor: 4.751

4.  Measurement of limb length inequality. Comparison of clinical methods with orthoradiography in 190 children.

Authors:  H I Lampe; B A Swierstra; A F Diepstraten
Journal:  Acta Orthop Scand       Date:  1996-06

5.  Arthroplasty of the hip. Leg length is not important.

Authors:  T O White; T W Dougall
Journal:  J Bone Joint Surg Br       Date:  2002-04

6.  Determination of leg length discrepancy. A comparison of weight-bearing and supine imaging.

Authors:  R H Cleveland; D C Kushner; M C Ogden; T E Herman; W Kermond; J A Correia
Journal:  Invest Radiol       Date:  1988-04       Impact factor: 6.016

7.  Factors influencing the improvement of gait ability after total hip arthroplasty.

Authors:  Riki Tanaka; Masamori Shigematsu; Tsutomu Motooka; Masaaki Mawatari; Takao Hotokebuchi
Journal:  J Arthroplasty       Date:  2009-07-30       Impact factor: 4.757

Review 8.  How reliable are reliability studies of fracture classifications? A systematic review of their methodologies.

Authors:  Laurent Audigé; Mohit Bhandari; James Kellam
Journal:  Acta Orthop Scand       Date:  2004-04

9.  Revision of aseptic loose total hip arthroplasties.

Authors:  H C Amstutz; S M Ma; R H Jinnah; L Mai
Journal:  Clin Orthop Relat Res       Date:  1982-10       Impact factor: 4.176

10.  Greater trochanteric pain after total hip arthroplasty: the incidence, clinical outcome and associated factors.

Authors:  A S Sayed-Noor; G O Sjoden
Journal:  Hip Int       Date:  2006 Jul-Sep       Impact factor: 1.756

View more
  18 in total

1.  Unstable hip arthroplasties. A prospective cohort study on seventy dislocating hips followed up for four years.

Authors:  Olle Wallner; André Stark; Olle Muren; Thomas Eisler; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-11-13       Impact factor: 3.075

2.  Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty.

Authors:  Sarwar S Mahmood; Bariq Al-Amiry; Sebastian S Mukka; Saida Baea; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2014-11-18       Impact factor: 2.199

3.  Does fluoroscopy improve acetabular component placement in total hip arthroplasty?

Authors:  Brandon S Beamer; Jordan H Morgan; Christopher Barr; Michael J Weaver; Mark S Vrahas
Journal:  Clin Orthop Relat Res       Date:  2014-09-20       Impact factor: 4.176

4.  Proceeding from direct lateral to anterolateral approach in total hip arthroplasty: A closer look on radiological and clinical aspects.

Authors:  Nils Wirries; Marco Ezechieli; Thilo Floerkemeier; Henning Windhagen; Michael Skutek
Journal:  J Orthop       Date:  2020-01-28

5.  Acetabular and Femoral Component Positioning Using Direct Anterior Approach Versus Posterior Approach in Total Hip Arthroplasty.

Authors:  Tarun Goyal; Arghya Kundu Choudhury; Souvik Paul; Tushar Gupta; Lakshmana Das
Journal:  Indian J Orthop       Date:  2021-03-10       Impact factor: 1.251

6.  The accuracy of component positioning during revision total hip arthroplasty using 3D optical computer-assisted navigation.

Authors:  Alex Tang; Vivek Singh; Mohamad Sharan; Mackenzie A Roof; John J Mercuri; Morteza Meftah; Ran Schwarzkopf
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-09-08

7.  [A new measurement method of offset in total hip arthroplasty].

Authors:  Wanming Qu; Hongbin Zhou; Peng Tian; Xiaorong Qin; You Zhang; Wenbin Shen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-04-15

8.  A higher reliability with a computed tomography scan-based three dimensional technique than with a two dimensional measurement for lower limb discrepancy in total hip arthroplasty planning.

Authors:  Elhadi Sariali; Matthias Mueller; Shahnaz Klouche
Journal:  Int Orthop       Date:  2021-08-04       Impact factor: 3.075

9.  Obesity does not influence acetabular component accuracy when using a 3D optical computer navigation system.

Authors:  Mohamad Sharan; Alex Tang; Lauren Schoof; Alexander Gaukhman; Morteza Meftah; Peter Sculco; Ran Schwarzkopf
Journal:  J Clin Orthop Trauma       Date:  2020-10-03

10.  Native femoral anteversion should not be used as reference in cementless total hip arthroplasty with a straight, tapered stem: a retrospective clinical study.

Authors:  Michael Worlicek; Markus Weber; Benjamin Craiovan; Michael Wörner; Florian Völlner; Hans R Springorum; Joachim Grifka; Tobias Renkawitz
Journal:  BMC Musculoskelet Disord       Date:  2016-09-20       Impact factor: 2.362

View more