Literature DB >> 15717191

Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants.

Antonius Rohlmann1, T Zander, G Bergmann.   

Abstract

Posteriorly and anteriorly fixed implants for stabilizing unstable spines are available on the market. Differences in the biomechanical behavior of these implant types are not yet fully clear. They were investigated using three-dimensional nonlinear finite element models of the lumbar spine in an intact state, with an anteriorly fixed MACS-TL implant and with posteriorly fixed internal fixators. The bisegmental implants spanned the L3 vertebra, and bone grafts were used with both implant types to replace parts of the two bridged discs. The computer models were loaded with partial body weight and muscle forces simulating standing, flexion, extension and axial rotation. Both implant types have reduced intersegmental rotation for flexion, extension, and axial rotation in the bridged region. The reduction is more pronounced for the MACS-TL implant. The implant type has only a minor effect on intradiscal pressure. Maximum von Mises stresses in the vertebrae are lower for flexion and extension with the MACS-TL implant than with the internal fixator. Very high stresses are predicted for flexion after insertion of internal fixators. For standing and torsion, maximum stresses differ only negligibly between the two implant types. In the period immediately after surgery, patients with osteoporotic vertebrae and who are treated with an internal spinal fixation device should therefore avoid excessive flexion. This study adds new information about the mechanical behavior of the lumbar spine after insertion of posterior and anterior spine-stabilizing implants. This information improves our biomechanical understanding of the spine.

Entities:  

Mesh:

Year:  2005        PMID: 15717191      PMCID: PMC3454656          DOI: 10.1007/s00586-004-0784-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  19 in total

1.  Intradiscal pressure together with anthropometric data--a data set for the validation of models.

Authors:  H Wilke; P Neef; B Hinz; H Seidel; L Claes
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001       Impact factor: 2.063

2.  Estimation of muscle forces in the lumbar spine during upper-body inclination.

Authors:  T Zander; A Rohlmann; J Calisse; G Bergmann
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001       Impact factor: 2.063

3.  Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices.

Authors:  J Calisse; A Rohlmann; G Bergmann
Journal:  J Biomech       Date:  1999-07       Impact factor: 2.712

4.  New in vivo measurements of pressures in the intervertebral disc in daily life.

Authors:  H J Wilke; P Neef; M Caimi; T Hoogland; L E Claes
Journal:  Spine (Phila Pa 1976)       Date:  1999-04-15       Impact factor: 3.468

5.  A follower load increases the load-carrying capacity of the lumbar spine in compression.

Authors:  A G Patwardhan; R M Havey; K P Meade; B Lee; B Dunlap
Journal:  Spine (Phila Pa 1976)       Date:  1999-05-15       Impact factor: 3.468

6.  ISSLS prize winner: A novel approach to determine trunk muscle forces during flexion and extension: a comparison of data from an in vitro experiment and in vivo measurements.

Authors:  H-J Wilke; A Rohlmann; S Neller; F Graichen; L Claes; G Bergmann
Journal:  Spine (Phila Pa 1976)       Date:  2003-12-01       Impact factor: 3.468

7.  Mechanical response of a lumbar motion segment in axial torque alone and combined with compression.

Authors:  A Shirazi-Adl; A M Ahmed; S C Shrivastava
Journal:  Spine (Phila Pa 1976)       Date:  1986-11       Impact factor: 3.468

8.  Interlaminar shear stresses and laminae separation in a disc. Finite element analysis of the L3-L4 motion segment subjected to axial compressive loads.

Authors:  V K Goel; B T Monroe; L G Gilbertson; P Brinckmann
Journal:  Spine (Phila Pa 1976)       Date:  1995-03-15       Impact factor: 3.468

9.  Cancellous bone Young's modulus variation within the vertebral body of a ligamentous lumbar spine--application of bone adaptive remodeling concepts.

Authors:  V K Goel; S A Ramirez; W Kong; L G Gilbertson
Journal:  J Biomech Eng       Date:  1995-08       Impact factor: 2.097

10.  A universal spine tester for in vitro experiments with muscle force simulation.

Authors:  H J Wilke; L Claes; H Schmitt; S Wolf
Journal:  Eur Spine J       Date:  1994       Impact factor: 3.134

View more
  9 in total

1.  Two column lesions in the thoracolumbar junction: anterior, posterior or combined approach? A comparative biomechanical in vitro investigation.

Authors:  Tibor Bence; Ulrich Schreiber; Thomas Grupp; Erwin Steinhauser; Wolfram Mittelmeier
Journal:  Eur Spine J       Date:  2006-08-30       Impact factor: 3.134

2.  Biomechanical evaluation of the Facet Wedge: a refined technique for facet fixation.

Authors:  René Hartensuer; Oliver Riesenbeck; Martin Schulze; Dominic Gehweiler; Michael J Raschke; Paul W Pavlov; Thomas Vordemvenne
Journal:  Eur Spine J       Date:  2014-08-26       Impact factor: 3.134

3.  Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplasty.

Authors:  Antonius Rohlmann; Thomas Zander; Georg Bergmann
Journal:  Eur Spine J       Date:  2005-11-26       Impact factor: 3.134

4.  Effect of an artificial disc on lumbar spine biomechanics: a probabilistic finite element study.

Authors:  Antonius Rohlmann; Anke Mann; Thomas Zander; Georg Bergmann
Journal:  Eur Spine J       Date:  2008-11-29       Impact factor: 3.134

5.  Biomechanical comparison of unilateral and bilateral pedicle screws fixation for transforaminal lumbar interbody fusion after decompressive surgery--a finite element analysis.

Authors:  Shih-Hao Chen; Shang-Chih Lin; Wen-Chi Tsai; Chih-Wei Wang; Shih-Heng Chao
Journal:  BMC Musculoskelet Disord       Date:  2012-05-16       Impact factor: 2.362

6.  Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure--a finite element study.

Authors:  Ching-Sung Kuo; Hsuan-Teh Hu; Ruey-Mo Lin; Kuo-Yuan Huang; Po-Chun Lin; Zheng-Cheng Zhong; Mu-Lin Hseih
Journal:  BMC Musculoskelet Disord       Date:  2010-07-05       Impact factor: 2.362

7.  Development and kinematic verification of a finite element model for the lumbar spine: application to disc degeneration.

Authors:  Elena Ibarz; Antonio Herrera; Yolanda Más; Javier Rodríguez-Vela; José Cegoñino; Sergio Puértolas; Luis Gracia
Journal:  Biomed Res Int       Date:  2012-12-05       Impact factor: 3.411

8.  Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques - a three-dimensional finite element analysis.

Authors:  Shih-Hao Chen; Ching-Lung Tai; Chien-Yu Lin; Pang-Hsing Hsieh; Weng-Pin Chen
Journal:  BMC Musculoskelet Disord       Date:  2008-06-18       Impact factor: 2.362

9.  Biomechanical Effects of Lateral Bending Position on Performing Cervical Spinal Manipulation for Cervical Disc Herniation: A Three-Dimensional Finite Element Analysis.

Authors:  Xuecheng Huang; Linqiang Ye; Zixian Wu; Lichang Liang; Qianli Wang; Weibo Yu; Xiaobing Jiang
Journal:  Evid Based Complement Alternat Med       Date:  2018-06-11       Impact factor: 2.629

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.