Literature DB >> 10400361

Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices.

J Calisse1, A Rohlmann, G Bergmann.   

Abstract

Direct quantitative measurement of muscle forces is not possible. Forces in the trunk muscles were estimated for standing and flexion of the upper body using three-dimensional, nonlinear finite element models of the lumbar spine with and without an internal spinal fixation device. Muscle forces assumed were two pairs dorsally and one ventrally, each representing several muscles. Muscle forces in the model with internal fixators were varied in discrete steps until the implant loads calculated closely corresponded to those measured in a patient with an instrumented implant. The calculated angles between adjacent lumbar vertebrae were compared with corresponding values measured on X-ray films of a patient as well as with literature values and served as a second criterion for predicting muscle forces. For the model without an implant, the muscle forces of the first model were slightly varied until the lumbar spine shape and the intradiscal pressure were physiological. The abdomen was shown to have a considerable supporting function for flexion.

Entities:  

Mesh:

Year:  1999        PMID: 10400361     DOI: 10.1016/s0021-9290(99)00052-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Survival without recovery after mass extinctions.

Authors:  David Jablonski
Journal:  Proc Natl Acad Sci U S A       Date:  2002-06-11       Impact factor: 11.205

2.  Influence of graded facetectomy and laminectomy on spinal biomechanics.

Authors:  T Zander; A Rohlmann; C Klöckner; G Bergmann
Journal:  Eur Spine J       Date:  2003-04-26       Impact factor: 3.134

3.  Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants.

Authors:  Antonius Rohlmann; T Zander; G Bergmann
Journal:  Eur Spine J       Date:  2005-02-17       Impact factor: 3.134

4.  Persons with unilateral transfemoral amputation experience larger spinal loads during level-ground walking compared to able-bodied individuals.

Authors:  Iman Shojaei; Brad D Hendershot; Erik J Wolf; Babak Bazrgari
Journal:  Clin Biomech (Bristol, Avon)       Date:  2015-12-04       Impact factor: 2.063

5.  Adjacent Disc Stress Following Floating Lumbar Spine Fusion: A Finite Element Study.

Authors:  Gunti Ranga Srinivas; Malhar N Kumar; Anindya Deb
Journal:  Asian Spine J       Date:  2017-08-07

6.  The Effect of Muscle Direction on the Predictions of Finite Element Model of Human Lumbar Spine.

Authors:  Rui Zhu; Wen-Xin Niu; Zhi-Peng Wang; Xiao-Long Pei; Bin He; Zhi-Li Zeng; Li-Ming Cheng
Journal:  Biomed Res Int       Date:  2018-01-03       Impact factor: 3.411

7.  Long-Term Effects of Segmental Lumbar Spinal Fusion on Adjacent Healthy Discs: A Finite Element Study.

Authors:  Gunti Ranga Srinivas; Anindya Deb; Malhar N Kumar; Goutham Kurnool
Journal:  Asian Spine J       Date:  2016-04-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.