Literature DB >> 11275349

Intradiscal pressure together with anthropometric data--a data set for the validation of models.

H Wilke1, P Neef, B Hinz, H Seidel, L Claes.   

Abstract

OBJECTIVE: To provide a database of intradiscal pressure measurements together with anthropometric data as basis for the validation of models that predict spinal loads.
DESIGN: Intradiscal pressure was measured in a non-degenerated L4-5 disc of a volunteer. The anthropometric characteristics of this subject were extensively determined.
BACKGROUND: Since it is usually impossible to quantify the load in the spine directly, it is predicted by various biomechanical models. However, they often cannot be validated because of the few in vivo data and missing anthropometric characteristics pertaining to them.
METHODS: A pressure transducer (diameter 1.5 mm) was implanted in the nucleus pulposus of a non-degenerated L4-5 disc of a volunteer. Pressure was determined during exercises while standing, lifting activities, sitting unsupported on a stool or an ergonomic sitting ball, sitting in different postures and others. The anthropometric characteristics were determined using different tools.
RESULTS: Pressure values: relaxed standing 0.5 MPa; standing flexed forward 1.1 MPa; standing extended backward 0.6 MPa; sitting unsupported 0.46 MPa; maximum values during lateral bending 0.6 MPa, during axial rotation 0.7 MPa, lifting a 20 kg weight with a round flexed back 2.3 MPa, with flexed knees 1.7 MPa, close to the body 1.1 MPa; sitting unsupported relaxed 0.45 MPa, actively straightening the back 0.55 MPa, with flexion 0.9 MPa; non-chalant sitting 0.3 MPa and others. Anthropometric characteristics with emphasis on data for the trunk are provided in tables.Conclusions. Intradiscal pressure depends on the kind of preceding activity, posture, external loads and muscle activity. RELEVANCE: The data set can be used to verify a biomechanical model adjusted to the individual characteristics by a comparison of measured and predicted intradiscal pressures.

Mesh:

Year:  2001        PMID: 11275349     DOI: 10.1016/s0268-0033(00)00103-0

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  47 in total

1.  Noninvasive Assessment of Biochemical and Mechanical Properties of Lumbar Discs Through Quantitative Magnetic Resonance Imaging in Asymptomatic Volunteers.

Authors:  Mary H Foltz; Craig C Kage; Casey P Johnson; Arin M Ellingson
Journal:  J Biomech Eng       Date:  2017-11-01       Impact factor: 2.097

2.  Influence of graded facetectomy and laminectomy on spinal biomechanics.

Authors:  T Zander; A Rohlmann; C Klöckner; G Bergmann
Journal:  Eur Spine J       Date:  2003-04-26       Impact factor: 3.134

3.  Effect of the intra-abdominal pressure and the center of segmental body mass on the lumbar spine mechanics - a computational parametric study.

Authors:  W M Park; S Wang; Y H Kim; K B Wood; J A Sim; G Li
Journal:  J Biomech Eng       Date:  2012-01       Impact factor: 2.097

4.  In vitro and in silico investigations of disc nucleus replacement.

Authors:  Sandra Reitmaier; Aboulfazl Shirazi-Adl; Maxim Bashkuev; Hans-Joachim Wilke; Antonio Gloria; Hendrik Schmidt
Journal:  J R Soc Interface       Date:  2012-02-15       Impact factor: 4.118

5.  Incorporating Six Degree-of-Freedom Intervertebral Joint Stiffness in a Lumbar Spine Musculoskeletal Model-Method and Performance in Flexed Postures.

Authors:  Xiangjie Meng; Alexander G Bruno; Bo Cheng; Wenjun Wang; Mary L Bouxsein; Dennis E Anderson
Journal:  J Biomech Eng       Date:  2015-10       Impact factor: 2.097

6.  Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants.

Authors:  Antonius Rohlmann; T Zander; G Bergmann
Journal:  Eur Spine J       Date:  2005-02-17       Impact factor: 3.134

7.  Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis.

Authors:  Antonius Rohlmann; Nagananda K Burra; Thomas Zander; Georg Bergmann
Journal:  Eur Spine J       Date:  2007-01-06       Impact factor: 3.134

8.  Back posture education in elementary schoolchildren: a 2-year follow-up study.

Authors:  Elisabeth Geldhof; Greet Cardon; Ilse De Bourdeaudhuij; Dirk De Clercq
Journal:  Eur Spine J       Date:  2006-09-30       Impact factor: 3.134

9.  Miniature fiber optic pressure sensor with composite polymer-metal diaphragm for intradiscal pressure measurements.

Authors:  Silas Nesson; Miao Yu; Xuming Zhang; Adam H Hsieh
Journal:  J Biomed Opt       Date:  2008 Jul-Aug       Impact factor: 3.170

10.  Effects of compressive loading on biomechanical properties of disc and peripheral tissue in a rat tail model.

Authors:  Tomokazu Nakamura; Takaro Iribe; Yoshinori Asou; Hiroo Miyairi; Kozo Ikegami; Kazuo Takakuda
Journal:  Eur Spine J       Date:  2009-06-26       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.