Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.

H C Segal1, C Briggs, S Kunka, A Casbard, P Harrison, S J Machin, M F Murphy.   

Abstract

Although haematology analysers provide reliable full blood counts, they are known to be inaccurate at enumerating platelets in severe thrombocytopenia. If the thresholds for platelet transfusion, currently set at 10 x 10(9)/l, are to be further reduced, it is vital that the limitations of current analysers are fully understood. The aim of this large multicentre study was to determine the accuracy of haematology analysers in current routine practice for platelet counts below 20 x 10(9)/l. Platelet counts estimated by analysers using optical, impedance and immunological methods were compared with the International Reference Method for platelet counting. The results demonstrated variation in platelet counting between different analysers and even the same type of analyser at different sites. Optical methods for platelet counting on the XE 2100, Advia 120, Cell-Dyn 4000 and H3* were not superior to impedance methods on the XE 2100, LH750 and Pentra analysers. All analysers except one overestimated the platelet count, which would result in under transfusion of platelets. This study highlights the inaccuracies of haematology analysers in platelet counting in severe thrombocytopenia. It re-emphasizes the need for external quality control to improve analyser calibration for samples with low platelet counts, and suggests that the optimal thresholds for prophylactic platelet transfusions should be re-evaluated.

Entities:  

Mesh:

Year:  2005        PMID: 15686462     DOI: 10.1111/j.1365-2141.2004.05352.x

Source DB:  PubMed          Journal:  Br J Haematol        ISSN: 0007-1048            Impact factor:   6.998


  17 in total

1.  Comparison of different platelet count thresholds to guide administration of prophylactic platelet transfusion for preventing bleeding in patients with haematological disorders after chemotherapy or stem cell transplantation.

Authors:  Lise J Estcourt; Simon Stanworth; Carolyn Doree; Marialena Trivella; Sally Hopewell; Michael F Murphy; Alan Tinmouth
Journal:  Cochrane Database Syst Rev       Date:  2014

2.  Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-series automated hematology analyzers.

Authors:  Yuzo Tanaka; Yumiko Tanaka; Kazumi Gondo; Yoshiko Maruki; Tamiaki Kondo; Satomi Asai; Hiromichi Matsushita; Hayato Miyachi
Journal:  J Clin Lab Anal       Date:  2014-03-19       Impact factor: 2.352

3.  Reproducibility of Manual Platelet Estimation Following Automated Low Platelet Counts.

Authors:  Zainab S Al-Hosni; Murtadha Al-Khabori; Sahimah Al-Mamari; Jamal Al-Qasabi; Hiedi Davis; Hatim Al-Lawati; Arwa Z Al-Riyami
Journal:  Oman Med J       Date:  2016-11

4.  Accuracy of Platelet Counting by Optical and Impedance Methods in Patients with Thrombocytopaenia and Microcytosis.

Authors:  Mohamed-Rachid Boulassel; Raya Al-Farsi; Sulaiman Al-Hashmi; Hamad Al-Riyami; Hammad Khan; Salam Al-Kindi
Journal:  Sultan Qaboos Univ Med J       Date:  2015-11-23

5.  Correction for effect of cold storage on immature platelet fraction.

Authors:  Andrew Osei-Bimpong; Mohammad Saleh; Martha Sola-Visner; John Widness; Peter Veng-Pedersen
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

6.  Performance Evaluation of Fully Automated 5-Part Differential Hematology Analyzer ELite 580 (ERBA).

Authors:  Shanaz Khodaiji; Dia Mansukhani
Journal:  Indian J Hematol Blood Transfus       Date:  2021-03-16       Impact factor: 0.900

Review 7.  Comparison of different platelet count thresholds to guide administration of prophylactic platelet transfusion for preventing bleeding in people with haematological disorders after myelosuppressive chemotherapy or stem cell transplantation.

Authors:  Lise J Estcourt; Simon J Stanworth; Carolyn Doree; Sally Hopewell; Marialena Trivella; Michael F Murphy
Journal:  Cochrane Database Syst Rev       Date:  2015-11-18

8.  Human erythrocyte fragmentation during ex-vivo pig organ perfusion.

Authors:  Zahra A Habibabady; Selin Sendil; Felix Ellett; Franziska Pollok; Gabriela F Elias; Beth M French; Wenji Sun; Gheorghe Braileanu; Lars Burdorf; Daniel Irimia; Richard N Pierson; Agnes M Azimzadeh
Journal:  Xenotransplantation       Date:  2022-02-02       Impact factor: 3.907

9.  Initial performance evaluation of the UniCel® DxH 800 Coulter® cellular analysis system.

Authors:  B D Hedley; M Keeney; I Chin-Yee; W Brown
Journal:  Int J Lab Hematol       Date:  2011-02       Impact factor: 2.877

Review 10.  Survey material choices in haematology EQA: a confounding factor in automated counting performance assessment.

Authors:  Barbara De la Salle
Journal:  Biochem Med (Zagreb)       Date:  2017-02-15       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.