Literature DB >> 15523967

Measuring visual acuity--mesopic or photopic conditions, and high or low contrast letters?

Konrad Pesudovs1, Jason D Marsack, William J Donnelly, Larry N Thibos, Raymond A Applegate.   

Abstract

PURPOSE: To develop single-valued wavefront aberration metrics that correlate strongly with visual performance. The purpose of this study is to explore whether photopic high contrast visual acuity (VA) is an appropriate visual performance reference and whether mesopic and/or low contrast testing provides any advantage.
METHODS: Subjects from the Texas Investigation of Cataract Optics study (N = 148) ranged in age from 21.6 to 83.8 years and from clear lens to dense nuclear cataract. Visual acuity was measured under four conditions: photopic high (VA(PHC)) and low (VA(PLC)) contrast, mesopic high (VA(MHC)) and low (VA(MLC)) contrast (photopic = 280 cd/m(2), mesopic = 0.75 cd/m(2)). Variables were tested for compliance with normality (-2.00 < skew and kurtosis < 2.00) and transformed if required. Linear regression and Bland-Altman 95% limits of agreement (+/-1.96 SD) were used to examine relationships between VA variables and between VA and wavefront aberration metrics.
RESULTS: The two photopic measures VA(PHC) (skew = 2.57, kurtosis = 12.2) and VA(PLC) (1.67, 5.41) were poorly distributed, but the two mesopic measures VA(MHC) (0.88, 1.67) and VA(MLC) (0.29, -0.18) were normally distributed. Strong correlations existed between the (transformed) VA variables (R: 0.53 to 0.84). However, limits of agreement ranged over 0.30 to 0.42 logMAR, whereas retest data suggested a range of 0.15. All four were offered in stepwise multiple linear regression for 30 wavefront metrics: 20 included VA(MLC) alone, two included VA(PLC), two included VA(MHC) and six included both VA(MLC) and VA(MHC); R(2) averaged 25%.
CONCLUSION: Although strongly correlated, low contrast and/or mesopic VA testing provides different information. Wave aberration metrics correlates better with VA(MLC) making this the visual performance test of choice.

Entities:  

Mesh:

Year:  2004        PMID: 15523967

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  21 in total

1.  Metrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity.

Authors:  Raymond A Applegate; Jason D Marsack; Larry N Thibos
Journal:  Optom Vis Sci       Date:  2006-09       Impact factor: 1.973

2.  Impact of Zernike-fit error on simulated high- and low-contrast acuity in keratoconus: implications for using Zernike-based corrections.

Authors:  Jason D Marsack; Konrad Pesudovs; Edwin J Sarver; Raymond A Applegate
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-04       Impact factor: 2.129

3.  Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging.

Authors:  Raymond A Applegate; William J Donnelly; Jason D Marsack; Darren E Koenig; Konrad Pesudovs
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-03       Impact factor: 2.129

Review 4.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part II: examples].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-11       Impact factor: 1.059

5.  [Wavefront aberrations and subjective quality of vision after wavefront-guided LASIK: first results].

Authors:  J Bühren; A Strenger; T Martin; T Kohnen
Journal:  Ophthalmologe       Date:  2007-08       Impact factor: 1.059

6.  Repeatability of mesopic visual acuity measurements using high- and low-contrast ETDRS letter charts.

Authors:  Ana Barrio; Beatriz Antona; María C Puell
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-12-09       Impact factor: 3.117

7.  Normative best-corrected values of the visual image quality metric VSX as a function of age and pupil size.

Authors:  Gareth D Hastings; Jason D Marsack; Larry N Thibos; Raymond A Applegate
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2018-05-01       Impact factor: 2.129

8.  Performance of wavefront-guided soft lenses in three keratoconus subjects.

Authors:  Jason D Marsack; Katrina E Parker; Raymond A Applegate
Journal:  Optom Vis Sci       Date:  2008-12       Impact factor: 1.973

9.  Controlled induction of spherical aberration with custom soft contact lenses.

Authors:  Katrina E Parker; Jason D Marsack; James D Elswick; Tyson J Brunstetter; Raymond A Applegate
Journal:  Clin Exp Optom       Date:  2009-04-01       Impact factor: 2.742

10.  Factors accounting for the 4-year change in acuity in patients between 50 and 80 years.

Authors:  Darren E Koenig; Lan Chi Nguyen; Katrina E Parker; Raymond A Applegate
Journal:  Optom Vis Sci       Date:  2013-07       Impact factor: 1.973