Ana Barrio1, Beatriz Antona, María C Puell. 1. Applied Vision Research Group, Faculty of Optics and Optometry, Complutense University of Madrid, Av. Arcos de Jalón 118, 28037, Madrid, Spain, arbarrio@ucm.es.
Abstract
PURPOSE: To determine the repeatability of mesopic high-contrast (HC) and low-contrast (LC) visual acuity (VA) measurements made at distance and near in healthy young individuals. While the repeatability of photopic VA is well-known, there is a lack of information with regard to the repeatability of VA measured under low luminance conditions. METHODS: In two different sessions 1 week apart, best-corrected monocular VA was determined using HC (96 %) and LC (10 %) ETDRS charts under mesopic luminance conditions (0.75 cd/m(2)) at distance (HCD, LCD) and near (HCN, LCN) in 47 healthy subjects aged 22.9 ± 6.8 years. Repeatability was estimated by the Bland and Altman method, whereby the mean difference (MD) and the 95 % limits of agreement were determined as the coefficient of repeatability (COR). RESULTS: Mean logMAR VA values were HCD = 0.09, LCD = 0.44, HCN = 0.21, and LCN = 0.57. Mean differences in measurements between sessions 1 and 2 were not significant, and low in clinical terms (≤1 letter). Repeatability was better for the distance measurements at both high and lowcontrast (COR HCD ±0.11 and COR LCD ±0.11 logMAR vs COR HCN ±0.15 and COR LCN ±0.16 logMAR), and MDs were also slightly closer to zero for the distance measurements. Similar repeatability was observed between HC and LC VA, both at distance and near. CONCLUSIONS: In mesopic conditions, ETDRS charts offer repeatable best-corrected monocular VA measurements. The criterion for a significant change in logMAR VA was 1 line at distance and 1.5 lines at near.
PURPOSE: To determine the repeatability of mesopic high-contrast (HC) and low-contrast (LC) visual acuity (VA) measurements made at distance and near in healthy young individuals. While the repeatability of photopic VA is well-known, there is a lack of information with regard to the repeatability of VA measured under low luminance conditions. METHODS: In two different sessions 1 week apart, best-corrected monocular VA was determined using HC (96 %) and LC (10 %) ETDRS charts under mesopic luminance conditions (0.75 cd/m(2)) at distance (HCD, LCD) and near (HCN, LCN) in 47 healthy subjects aged 22.9 ± 6.8 years. Repeatability was estimated by the Bland and Altman method, whereby the mean difference (MD) and the 95 % limits of agreement were determined as the coefficient of repeatability (COR). RESULTS: Mean logMAR VA values were HCD = 0.09, LCD = 0.44, HCN = 0.21, and LCN = 0.57. Mean differences in measurements between sessions 1 and 2 were not significant, and low in clinical terms (≤1 letter). Repeatability was better for the distance measurements at both high and lowcontrast (COR HCD ±0.11 and COR LCD ±0.11 logMAR vs COR HCN ±0.15 and COR LCN ±0.16 logMAR), and MDs were also slightly closer to zero for the distance measurements. Similar repeatability was observed between HC and LC VA, both at distance and near. CONCLUSIONS: In mesopic conditions, ETDRS charts offer repeatable best-corrected monocular VA measurements. The criterion for a significant change in logMAR VA was 1 line at distance and 1.5 lines at near.
Authors: Konrad Pesudovs; Jason D Marsack; William J Donnelly; Larry N Thibos; Raymond A Applegate Journal: J Refract Surg Date: 2004 Sep-Oct Impact factor: 3.573
Authors: Kavita P Dhamdhere; Marilyn E Schneck; Marcus A Bearse; Wendy Lam; Shirin Barez; Anthony J Adams Journal: Invest Ophthalmol Vis Sci Date: 2014-05-13 Impact factor: 4.799
Authors: Reuben R Shamir; Yael G Friedman; Leo Joskowicz; Michael Mimouni; Eytan Z Blumenthal Journal: Graefes Arch Clin Exp Ophthalmol Date: 2016-01-07 Impact factor: 3.117
Authors: Laura J Balcer; Jenelle Raynowska; Rachel Nolan; Steven L Galetta; Raju Kapoor; Ralph Benedict; Glenn Phillips; Nicholas LaRocca; Lynn Hudson; Richard Rudick Journal: Mult Scler Date: 2017-02-16 Impact factor: 6.312
Authors: Laura J Wood; Jasleen K Jolly; Amandeep S Josan; Thomas M W Buckley; Robert E MacLaren Journal: Transl Vis Sci Technol Date: 2021-02-05 Impact factor: 3.283