Literature DB >> 25488572

Repeatability of mesopic visual acuity measurements using high- and low-contrast ETDRS letter charts.

Ana Barrio1, Beatriz Antona, María C Puell.   

Abstract

PURPOSE: To determine the repeatability of mesopic high-contrast (HC) and low-contrast (LC) visual acuity (VA) measurements made at distance and near in healthy young individuals. While the repeatability of photopic VA is well-known, there is a lack of information with regard to the repeatability of VA measured under low luminance conditions.
METHODS: In two different sessions 1 week apart, best-corrected monocular VA was determined using HC (96 %) and LC (10 %) ETDRS charts under mesopic luminance conditions (0.75 cd/m(2)) at distance (HCD, LCD) and near (HCN, LCN) in 47 healthy subjects aged 22.9 ± 6.8 years. Repeatability was estimated by the Bland and Altman method, whereby the mean difference (MD) and the 95 % limits of agreement were determined as the coefficient of repeatability (COR).
RESULTS: Mean logMAR VA values were HCD = 0.09, LCD = 0.44, HCN = 0.21, and LCN = 0.57. Mean differences in measurements between sessions 1 and 2 were not significant, and low in clinical terms (≤1 letter). Repeatability was better for the distance measurements at both high and lowcontrast (COR HCD ±0.11 and COR LCD ±0.11 logMAR vs COR HCN ±0.15 and COR LCN ±0.16 logMAR), and MDs were also slightly closer to zero for the distance measurements. Similar repeatability was observed between HC and LC VA, both at distance and near.
CONCLUSIONS: In mesopic conditions, ETDRS charts offer repeatable best-corrected monocular VA measurements. The criterion for a significant change in logMAR VA was 1 line at distance and 1.5 lines at near.

Entities:  

Mesh:

Year:  2014        PMID: 25488572     DOI: 10.1007/s00417-014-2876-z

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  32 in total

1.  Efficacy of measuring visual performance of LASIK patients under photopic and mesopic conditions.

Authors:  Wilfred Tang; Wee-Jin Heng; Hung-Ming Lee; Han-Bor Fam; Nai-Shin Lai
Journal:  Ann Acad Med Singapore       Date:  2006-08       Impact factor: 2.473

2.  Repeatability of near visual acuity measurement at high and low contrast.

Authors:  Andrew K C Lam; Cecilia Tong; Jimmy Tse; Man Yu
Journal:  Clin Exp Optom       Date:  2008-09       Impact factor: 2.742

3.  Vision through an abnormal cornea: a pilot study of the relationship between visual loss from corneal distortion, corneal edema, keratoconus, and some allied corneal pathology.

Authors:  R F Hess; L G Carney
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-05       Impact factor: 4.799

Review 4.  Clinical and immunologic characteristics of melanoma-associated retinopathy syndrome: eleven new cases and a review of 51 previously published cases.

Authors:  J L Keltner; C E Thirkill; P T Yip
Journal:  J Neuroophthalmol       Date:  2001-09       Impact factor: 3.042

5.  Recessive mutations in the RLBP1 gene encoding cellular retinaldehyde-binding protein in a form of retinitis punctata albescens.

Authors:  H Morimura; E L Berson; T P Dryja
Journal:  Invest Ophthalmol Vis Sci       Date:  1999-04       Impact factor: 4.799

6.  Measuring visual acuity--mesopic or photopic conditions, and high or low contrast letters?

Authors:  Konrad Pesudovs; Jason D Marsack; William J Donnelly; Larry N Thibos; Raymond A Applegate
Journal:  J Refract Surg       Date:  2004 Sep-Oct       Impact factor: 3.573

7.  The SKILL Card. An acuity test of reduced luminance and contrast. Smith-Kettlewell Institute Low Luminance.

Authors:  G Haegerstrom-Portnoy; J Brabyn; M E Schneck; A Jampolsky
Journal:  Invest Ophthalmol Vis Sci       Date:  1997-01       Impact factor: 4.799

8.  The use of accurate visual acuity measurements in clinical anti-cataract formulation trials.

Authors:  D B Elliott; M Sheridan
Journal:  Ophthalmic Physiol Opt       Date:  1988       Impact factor: 3.117

9.  Assessment of macular function using the SKILL Card in adults with type 2 diabetes mellitus.

Authors:  Kavita P Dhamdhere; Marilyn E Schneck; Marcus A Bearse; Wendy Lam; Shirin Barez; Anthony J Adams
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-05-13       Impact factor: 4.799

10.  Reliability of high- and low-contrast letter charts.

Authors:  B C Reeves; J M Wood; A R Hill
Journal:  Ophthalmic Physiol Opt       Date:  1993-01       Impact factor: 3.117

View more
  4 in total

1.  The influence of varying the number of characters per row on the accuracy and reproducibility of the ETDRS visual acuity chart.

Authors:  Reuben R Shamir; Yael G Friedman; Leo Joskowicz; Michael Mimouni; Eytan Z Blumenthal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-01-07       Impact factor: 3.117

2.  Mesopic visual acuity is less crowded.

Authors:  František Pluháček; John Siderov
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-05-28       Impact factor: 3.117

Review 3.  Validity of low-contrast letter acuity as a visual performance outcome measure for multiple sclerosis.

Authors:  Laura J Balcer; Jenelle Raynowska; Rachel Nolan; Steven L Galetta; Raju Kapoor; Ralph Benedict; Glenn Phillips; Nicholas LaRocca; Lynn Hudson; Richard Rudick
Journal:  Mult Scler       Date:  2017-02-16       Impact factor: 6.312

4.  Low Luminance Visual Acuity and Low Luminance Deficit in Choroideremia and RPGR-Associated Retinitis Pigmentosa.

Authors:  Laura J Wood; Jasleen K Jolly; Amandeep S Josan; Thomas M W Buckley; Robert E MacLaren
Journal:  Transl Vis Sci Technol       Date:  2021-02-05       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.