Literature DB >> 15348670

Serum and urine metal levels in patients with metal-on-metal surface arthroplasty.

Anastasia K Skipor1, Patricia A Campbell, Leslie M Patterson, Harlan C Anstutz, Thomas P Schmalzried, Joshua J Jacobs.   

Abstract

The resurgence of metal-on-metal articulating surfaces for hip arthroplasty has also heightened concerns about the degree and magnitude of metal particle generation and the accompanying increase in circulating metal ion concentrations. In this study, we measured the concentration of chromium in serum and urine and the concentration of cobalt in serum in twenty-five patients with modern metal-on-metal surface arthroplasty of the hip in a prospective manner. The results showed that the mean post-operative chromium in serum levels were 22-fold, 23-fold and 21-fold higher at 3, 6 and 12 months post-operative, respectively, than pre-operative levels. The mean post-operative cobalt in serum levels were 8-fold, 7-fold and 6-fold higher at 3, 6 and 12 months post-operative, respectively, than pre-operative levels. The mean post-operative chromium in urine levels were 9-fold, 10-fold and 14-fold higher at 3, 6 and 12 months post-operative, respectively, than pre-operative levels. The values seen in this study with the current generation of surface arthroplasties are: (a) lower than those seen in an earlier generation of surface arthroplasties; (b) in the same range as those observed in association with metal-on-metal conventional total hip replacements, which typically have smaller head sizes; (c) higher than values observed in patients with conventional metal-on-polyethylene articulating couples.

Entities:  

Year:  2002        PMID: 15348670     DOI: 10.1023/a:1021179029640

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  47 in total

1.  Increased blood cobalt and chromium after total hip replacement.

Authors:  A W Schaffer; A Pilger; C Engelhardt; K Zweymueller; H W Ruediger
Journal:  J Toxicol Clin Toxicol       Date:  1999

2.  Wear debris from two different alumina-on-alumina total hip arthroplasties.

Authors:  M Böhler; Y Mochida; T W Bauer; H Plenk; M Salzer
Journal:  J Bone Joint Surg Br       Date:  2000-08

3.  Evolution and development of surface replacement arthroplasty.

Authors:  M E Steinberg
Journal:  Orthop Clin North Am       Date:  1982-10       Impact factor: 2.472

4.  Socket and cup surface replacement of the hip.

Authors:  A Nishio; M Eguchi; N Kaibara
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

5.  Wagner surface replacement arthroplasty of the hip. Analysis of fourteen failures in forty-one hips.

Authors:  W C Head
Journal:  J Bone Joint Surg Am       Date:  1981-03       Impact factor: 5.284

6.  Metal on metal surface replacement of the hip. Experience of the McMinn prothesis.

Authors:  D McMinn; R Treacy; K Lin; P Pynsent
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

7.  THARIES surface replacements: a review of the first 100 cases.

Authors:  H C Amstutz; A Graff-Radford; T A Gruen; I C Clarke
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

8.  Cemented double cup arthroplasty of the hip: a 5 year experience with the ICLH prosthesis.

Authors:  M A Freeman; H U Cameron; G C Brown
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

9.  Survivorship comparison of THARIES and conventional hip arthroplasty in patients younger than 40 years old.

Authors:  W C Kim; T Grogan; H C Amstutz; F Dorey
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

10.  A study of implant failure in the Wagner resurfacing arthroplasty.

Authors:  R S Bell; J Schatzker; V L Fornasier; S B Goodman
Journal:  J Bone Joint Surg Am       Date:  1985-10       Impact factor: 5.284

View more
  21 in total

Review 1.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 2.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

Review 3.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

Review 4.  What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty.

Authors:  Deborah J Hall; Robin Pourzal; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2020-01-15       Impact factor: 4.757

5.  Do ion levels in hip resurfacing differ from metal-on-metal THA at midterm?

Authors:  A Moroni; L Savarino; M Hoque; M Cadossi; N Baldini
Journal:  Clin Orthop Relat Res       Date:  2010-06-11       Impact factor: 4.176

Review 6.  [Metal-on-metal hybrid hip resurfacing. Development and current state].

Authors:  M Hoberg; M J Le Duff; H C Amstutz
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

7.  Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-02-01

8.  Release of Cu2+ from a copper-filled TiO2 coating in a rabbit model for total knee arthroplasty.

Authors:  Andreas Mauerer; Bastian Lange; Goetz Hannes Welsch; Frank Heidenau; Werner Adler; Raimund Forst; Richard Heiner Richter
Journal:  J Mater Sci Mater Med       Date:  2013-12-17       Impact factor: 3.896

9.  Does femoral neck to cup impingement affect metal ion levels in hip resurfacing?

Authors:  Michel J Le Duff; Alicia J Johnson; Andrew J Wassef; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

10.  Does ion release differ between hip resurfacing and metal-on-metal THA?

Authors:  Antonio Moroni; Lucia Savarino; Matteo Cadossi; Nicola Baldini; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2008-01-09       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.