Literature DB >> 18196364

Does ion release differ between hip resurfacing and metal-on-metal THA?

Antonio Moroni1, Lucia Savarino, Matteo Cadossi, Nicola Baldini, Sandro Giannini.   

Abstract

UNLABELLED: Modern metal-on-metal hip resurfacing was introduced as a bone-preserving method of joint reconstruction for young and active patients; however, the large diameter of the bearing surfaces is of concern for potential increased metal ion release. We hypothesized there were no differences in serum concentrations of chromium, cobalt, and molybdenum between patients who had metal-on-metal hip resurfacing (Group A; average head diameter, 48 mm; median followup, 24 months) and patients who had 28-mm metal-on-metal THA (Group B; median followup, 25 months). Serum concentrations also were compared with concentrations in healthy subjects. We identified no differences in ion levels between Groups A and B. A distinction was made according to gender. Women showed a higher chromium release in Group A whereas men had a higher cobalt release in Group B. Values obtained from Group A were higher than those of the control subjects. Our data suggest metal-on-metal bearings for THA should not be rejected because of concern regarding potential increased metal ion release; however, patients with elevated ion levels, even without loosening or toxicity, could be at higher risk and should be followed up periodically. LEVEL OF EVIDENCE: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18196364      PMCID: PMC2505207          DOI: 10.1007/s11999-007-0106-2

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  41 in total

1.  The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.

Authors:  S L Smith; D Dowson; A A Goldsmith
Journal:  Proc Inst Mech Eng H       Date:  2001       Impact factor: 1.617

2.  Serum cobalt levels after metal-on-metal total hip arthroplasty.

Authors:  Wolfram Brodner; Peter Bitzan; Vanee Meisinger; Alexandra Kaider; Florian Gottsauner-Wolf; Rainer Kotz
Journal:  J Bone Joint Surg Am       Date:  2003-11       Impact factor: 5.284

3.  Increased blood cobalt and chromium after total hip replacement.

Authors:  A W Schaffer; A Pilger; C Engelhardt; K Zweymueller; H W Ruediger
Journal:  J Toxicol Clin Toxicol       Date:  1999

4.  How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?

Authors:  Diane L Back; D A Young; A J Shimmin
Journal:  Clin Orthop Relat Res       Date:  2005-09       Impact factor: 4.176

5.  Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution.

Authors:  C Montero-Ocampo; H Lopez; A Salinas Rodriguez
Journal:  J Biomed Mater Res       Date:  1996-12

6.  Sister chromatid exchanges and ion release in patients wearing fracture fixation devices.

Authors:  L Savarino; S Stea; D Granchi; M Visentin; G Ciapetti; M E Donati; G Rollo; G Zinghi; A Pizzoferrato; L Montanaro; A Toni
Journal:  J Biomed Mater Res       Date:  2000-04

Review 7.  Distribution of cobalt chromium wear and corrosion products and biologic reactions.

Authors:  K Merritt; S A Brown
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

Review 8.  Metal-on-Metal total hip replacement: what does the literature say?

Authors:  John H Dumbleton; Michael T Manley
Journal:  J Arthroplasty       Date:  2005-02       Impact factor: 4.757

Review 9.  Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.

Authors:  P-A Vendittoli; S Mottard; A G Roy; C Dupont; M Lavigne
Journal:  J Bone Joint Surg Br       Date:  2007-04

10.  Bone-resorbing cytokines in serum of patients with aseptic loosening of hip prostheses.

Authors:  D Granchi; E Verri; G Ciapetti; S Stea; L Savarino; A Sudanese; M Mieti; R Rotini; D Dallari; G Zinghi; L Montanaro
Journal:  J Bone Joint Surg Br       Date:  1998-09
View more
  12 in total

1.  Bone mineral density of the proximal femur recovers after metal-on-metal hip resurfacing.

Authors:  Matteo Cadossi; Antonio Moroni; Matteo Romagnoli; Eugenio Chiarello; Cesare Faldini; Sandro Giannini
Journal:  Clin Cases Miner Bone Metab       Date:  2010-05

2.  Acetabular component thickness does not affect mid-term clinical results in hip resurfacing.

Authors:  Mariam Al-Hamad; Michel J Le Duff; Karren M Takamura; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2014-01-22       Impact factor: 4.176

3.  Do ion levels in hip resurfacing differ from metal-on-metal THA at midterm?

Authors:  A Moroni; L Savarino; M Hoque; M Cadossi; N Baldini
Journal:  Clin Orthop Relat Res       Date:  2010-06-11       Impact factor: 4.176

4.  What are the risks accompanying the reduced wear benefit of low-clearance hip resurfacing?

Authors:  Joseph Daniel; Hena Ziaee; Amir Kamali; Chandra Pradhan; Derek McMinn
Journal:  Clin Orthop Relat Res       Date:  2012-07-24       Impact factor: 4.176

5.  Do ion levels in metal-on-metal hip resurfacing differ from those in metal-on-metal THA at long-term followup?

Authors:  Lucia Savarino; Matteo Cadossi; Eugenio Chiarello; Nicola Baldini; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2013-04-10       Impact factor: 4.176

6.  Contact patch to rim distance predicts metal ion levels in hip resurfacing.

Authors:  James P Yoon; Michel J Le Duff; Alicia J Johnson; Karren M Takamura; Edward Ebramzadeh; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2012-11-27       Impact factor: 4.176

7.  Metal ion levels and functional results after either resurfacing hip arthroplasty or conventional metal-on-metal hip arthroplasty.

Authors:  José M H Smolders; Annemiek Hol; Willard J Rijnberg; Job L C van Susante
Journal:  Acta Orthop       Date:  2011-10       Impact factor: 3.717

Review 8.  The clinical and radiological outcomes of hip resurfacing versus total hip arthroplasty: a meta-analysis and systematic review.

Authors:  Toby O Smith; Rachel Nichols; Simon T Donell; Caroline B Hing
Journal:  Acta Orthop       Date:  2010-11-11       Impact factor: 3.717

Review 9.  Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

Authors:  Albrecht Hartmann; Franziska Hannemann; Jörg Lützner; Andreas Seidler; Hans Drexler; Klaus-Peter Günther; Jochen Schmitt
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

Review 10.  Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: a literature overview.

Authors:  Christopher Jantzen; Henrik L Jørgensen; Benn R Duus; Sune L Sporring; Jes B Lauritzen
Journal:  Acta Orthop       Date:  2013-04-18       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.