Investigation of x-ray spectra for iodinated contrast-enhanced dedicated breast CT.

Stephen J Glick1, Andrey Makeev1.   

Abstract

Screening for breast cancer with mammography has been very successful, resulting in part to a reduction of breast cancer mortality by approximately 39% since 1990. However, mammography still has limitations in performance, especially for women with dense breast tissue. Iodinated contrast-enhanced, dedicated breast CT (BCT) has been proposed to improve lesion analysis and the accuracy of diagnostic workup for patients suspected of having breast cancer. A mathematical analysis to explore the use of various x-ray filters for iodinated contrast-enhanced BCT is presented. To assess task-based performance, the ideal linear observer signal-to-noise ratio (SNR) is used as a figure-of-merit under the assumptions of a linear, shift-invariant imaging system. To estimate signal and noise propagation through the BCT detector, a parallel-cascade model was used. The lesion model was embedded into a structured background and included a realistic level of iodine uptake. SNR was computed for 84,000 different exposure settings by varying the kV setting, x-ray filter materials and thickness, breast size, and composition and radiation dose. It is shown that some x-ray filter material/thickness combinations can provide up to 75% improvement in the linear ideal observer SNR over a conventionally used x-ray filter for BCT. This improvement in SNR can be traded off for substantial reductions in mean glandular dose.

Entities:  

Keywords:  breast CT; iodine contrast agent; parallel-cascade model

Year:  2017        PMID: 28149923      PMCID: PMC5267057          DOI: 10.1117/1.JMI.4.1.013504

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  42 in total

1.  Multiple enhancing lesions detected on dynamic helical computed tomography-mammography.

Authors:  Mizuki Nishino; Katsumi Hayakawa; Akira Yamamoto; Yoshiaki Nakamura; Taisuke Morimoto; Sumio Mukaihara; Yoji Urata
Journal:  J Comput Assist Tomogr       Date:  2003 Sep-Oct       Impact factor: 1.826

2.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

3.  Contrast-enhanced dedicated breast CT: initial clinical experience.

Authors:  Nicolas D Prionas; Karen K Lindfors; Shonket Ray; Shih-Ying Huang; Laurel A Beckett; Wayne L Monsky; John M Boone
Journal:  Radiology       Date:  2010-09       Impact factor: 11.105

Review 4.  Advanced applications of digital mammography: tomosynthesis and contrast-enhanced digital mammography.

Authors:  John M Lewin; Loren Niklason
Journal:  Semin Roentgenol       Date:  2007-10       Impact factor: 0.800

5.  Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast.

Authors:  Ioannis Sechopoulos; Srinivasan Vedantham; Sankararaman Suryanarayanan; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2008-02-21       Impact factor: 11.105

6.  Spectral optimization for dedicated breast CT.

Authors:  Michaela Weigel; Sabrina V Vollmar; Willi A Kalender
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

Review 7.  Dedicated breast computed tomography: Basic aspects.

Authors:  Antonio Sarno; Giovanni Mettivier; Paolo Russo
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

8.  Evaluating noise reduction techniques while considering anatomical noise in dual-energy contrast-enhanced mammography.

Authors:  Nicholas Allec; Shiva Abbaszadeh; Chris C Scott; Karim S Karim; John M Lewin
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

9.  Experimentally determined spectral optimization for dedicated breast computed tomography.

Authors:  Nicolas D Prionas; Shih-Ying Huang; John M Boone
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

10.  Human observer detection experiments with mammograms and power-law noise.

Authors:  A E Burgess; F L Jacobson; P F Judy
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

View more
  1 in total

1.  Effects of kV, filtration, dose, and object size on soft tissue and iodine contrast in dedicated breast CT.

Authors:  Andrew M Hernandez; Craig K Abbey; Peymon Ghazi; George Burkett; John M Boone
Journal:  Med Phys       Date:  2020-04-27       Impact factor: 4.071

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.