Literature DB >> 9048370

System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography.

S Hejazi1, D P Trauernicht.   

Abstract

System modeling is used to investigate the effect of various system parameters on the image quality in CCD-based x-ray imaging systems. The systems considered consist of a typical phosphor-based scintillating screen coupled to a CCD through lens or fiberoptic taper. Two applications, chest radiography and mammography, are analyzed. For each application typical system characteristics and operating conditions are used to determine the detective quantum efficiency (DQE) as a function of spatial frequency, optical collection efficiency, optical demagnification factor, and electronic noise. The DQE is modeled by extending the analysis for storage phosphor systems. The calculations are done for typical exposure conditions (0.25 mR for chest and 10.0 mR for mammography); however, the exposure effects are also discussed. It was found that a reasonable DQE can be obtained for both applications through each coupling approach; however, the demagnification requirements and electronic noise limitations are more stringent for the digital mammography application.

Mesh:

Year:  1997        PMID: 9048370     DOI: 10.1118/1.598072

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; D Albagli; S Han; E J Tkaczyk; C E Landberg; B Opsahl-Ong; P R Granfors; I Levis; C J D'Orsi; R E Hendrick
Journal:  Med Phys       Date:  2000-03       Impact factor: 4.071

2.  Breast imaging using an amorphous silicon-based full-field digital mammographic system: stability of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; C J D'Orsi; R E Hendrick
Journal:  J Digit Imaging       Date:  2000-11       Impact factor: 4.056

3.  DR with a DSLR: Digital Radiography with a Digital Single-Lens Reflex camera.

Authors:  Helen Fan; Heather L Durko; Stephen K Moore; Jared Moore; Brian W Miller; Lars R Furenlid; Sunil Pradhan; Harrison H Barrett
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-15

4.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

5.  Comparison of two detector systems for cone beam CT small animal imaging - a preliminary study.

Authors:  Yang Meng; Chris C Shaw; Xinming Liu; Mustafa C Altunbas; Tianpeng Wang; Lingyun Chen; Shu-Ju Tu; S Cheenu Kappadath; Chao-Jen Lai
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-02

6.  Dual resolution cone beam breast CT: a feasibility study.

Authors:  Lingyun Chen; Youtao Shen; Chao-Jen Lai; Tao Han; Yuncheng Zhong; Shuaiping Ge; Xinming Liu; Tianpeng Wang; Wei T Yang; Gary J Whitman; Chris C Shaw
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

7.  New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy.

Authors:  Stephen Rudin; Andrew T Kuhls; Girijesh K Yadava; Gaurav C Josan; Ye Wu; Ravishankar N Chityala; Hussain S Rangwala; N Ciprian Ionita; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-12-02

8.  Simulation of the precision limits of plastic scintillation detectors using optimal component selection.

Authors:  Frédéric Lacroix; Luc Beaulieu; Louis Archambault; A Sam Beddar
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

9.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

10.  Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance.

Authors:  Niral M Sheth; Wojciech Zbijewski; Matthew W Jacobson; Godwin Abiola; Gerhard Kleinszig; Sebastian Vogt; Stefan Soellradl; Jens Bialkowski; William S Anderson; Clifford R Weiss; Greg M Osgood; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2018-11-13       Impact factor: 4.071

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.