Literature DB >> 15191143

Nonuniform noise propagation by using the ramp filter in fan-beam computed tomography.

Gengsheng L Zeng1.   

Abstract

It is observed that when the homogeneity property of the ramp filter is used to derive a filtered backprojection algorithm in fan-beam tomography, the reconstructed images have nonstationary frequency components and nonstationary noise. When a short focal-length is used, higher frequency components are amplified more at the edge of the image than at the center of the image, resulting in higher noise at the edge of the image.

Mesh:

Year:  2004        PMID: 15191143     DOI: 10.1109/tmi.2004.826943

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  14 in total

1.  Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Authors:  Adam Wunderlich; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

2.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  Filtered Backprojection Reconstruction with Depth-Dependent Filtering.

Authors:  Frank Dennerlein; Holger Kunze; Frédéric Noo
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

4.  An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.

Authors:  Jing Wang; Hongbing Lu; Tianfang Li; Zhengrong Liang
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

5.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

6.  Local and global 3D noise power spectrum in cone-beam CT system with FDK reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

7.  The fan-beam short-scan FBP algorithm is not exact.

Authors:  G L Zeng
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

8.  Raw data normalization for a multi source inverse geometry CT system.

Authors:  Jongduk Baek; Bruno De Man; Daniel Harrison; Norbert J Pelc
Journal:  Opt Express       Date:  2015-03-23       Impact factor: 3.894

9.  Statistical characterization of noise for spatial standardization of CT scans: Enabling comparison with multiple kernels and doses.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Maria J Ledesma-Carbayo; George R Washko; Raúl San José Estépar
Journal:  Med Image Anal       Date:  2017-06-07       Impact factor: 8.545

10.  Autocalibration method for non-stationary CT bias correction.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Maria J Ledesma-Carbayo; George R Washko; Raúl San José Estépar
Journal:  Med Image Anal       Date:  2017-12-08       Impact factor: 8.545

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.