Autocalibration method for non-stationary CT bias correction.

Gonzalo Vegas-Sánchez-Ferrero1, Maria J Ledesma-Carbayo2, George R Washko3, Raúl San José Estépar3.   

Abstract

Computed tomography (CT) is a widely used imaging modality for screening and diagnosis. However, the deleterious effects of radiation exposure inherent in CT imaging require the development of image reconstruction methods which can reduce exposure levels. The development of iterative reconstruction techniques is now enabling the acquisition of low-dose CT images whose quality is comparable to that of CT images acquired with much higher radiation dosages. However, the characterization and calibration of the CT signal due to changes in dosage and reconstruction approaches is crucial to provide clinically relevant data. Although CT scanners are calibrated as part of the imaging workflow, the calibration is limited to select global reference values and does not consider other inherent factors of the acquisition that depend on the subject scanned (e.g. photon starvation, partial volume effect, beam hardening) and result in a non-stationary noise response. In this work, we analyze the effect of reconstruction biases caused by non-stationary noise and propose an autocalibration methodology to compensate it. Our contributions are: 1) the derivation of a functional relationship between observed bias and non-stationary noise, 2) a robust and accurate method to estimate the local variance, 3) an autocalibration methodology that does not necessarily rely on a calibration phantom, attenuates the bias caused by noise and removes the systematic bias observed in devices from different vendors. The validation of the proposed methodology was performed with a physical phantom and clinical CT scans acquired with different configurations (kernels, doses, algorithms including iterative reconstruction). The results confirmed the suitability of the proposed methods for removing the intra-device and inter-device reconstruction biases.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bias; Computed tomography; Low-dose; Non-stationary noise

Mesh:

Year:  2017        PMID: 29247875      PMCID: PMC6071427          DOI: 10.1016/j.media.2017.12.004

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  23 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 2.  Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction.

Authors:  Ji Yung Choo; Jin Mo Goo; Chang Hyun Lee; Chang Min Park; Sang Joon Park; Mi-Suk Shim
Journal:  Eur Radiol       Date:  2013-11-26       Impact factor: 5.315

3.  Quantitative imaging test approval and biomarker qualification: interrelated but distinct activities.

Authors:  Andrew J Buckler; Linda Bresolin; N Reed Dunnick; Daniel C Sullivan; Hugo J W L Aerts; Bernard Bendriem; Claus Bendtsen; Ronald Boellaard; John M Boone; Patricia E Cole; James J Conklin; Gary S Dorfman; Pamela S Douglas; Willy Eidsaunet; Cathy Elsinger; Richard A Frank; Constantine Gatsonis; Maryellen L Giger; Sandeep N Gupta; David Gustafson; Otto S Hoekstra; Edward F Jackson; Lisa Karam; Gary J Kelloff; Paul E Kinahan; Geoffrey McLennan; Colin G Miller; P David Mozley; Keith E Muller; Rick Patt; David Raunig; Mark Rosen; Haren Rupani; Lawrence H Schwartz; Barry A Siegel; A Gregory Sorensen; Richard L Wahl; John C Waterton; Walter Wolf; Gudrun Zahlmann; Brian Zimmerman
Journal:  Radiology       Date:  2011-02-15       Impact factor: 11.105

4.  Spatially variant noise estimation in MRI: a homomorphic approach.

Authors:  Santiago Aja-Fernández; Tomasz Pieciak; Gonzalo Vegas-Sánchez-Ferrero
Journal:  Med Image Anal       Date:  2014-11-24       Impact factor: 8.545

5.  Denoising of polychromatic CT images based on their own noise properties.

Authors:  Ji Hye Kim; Yongjin Chang; Jong Beom Ra
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

6.  Statistical characterization of noise for spatial standardization of CT scans: Enabling comparison with multiple kernels and doses.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Maria J Ledesma-Carbayo; George R Washko; Raúl San José Estépar
Journal:  Med Image Anal       Date:  2017-06-07       Impact factor: 8.545

Review 7.  Impact of obesity on medical imaging and image-guided intervention.

Authors:  Raul N Uppot; Dushyant V Sahani; Peter F Hahn; Debra Gervais; Peter R Mueller
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

8.  Energy dependence in the spectral factor approach to computed tomography.

Authors:  D F Jackson; D J Hawkes
Journal:  Phys Med Biol       Date:  1983-03       Impact factor: 3.609

9.  Influence of calibration on densitometric studies of emphysema progression using computed tomography.

Authors:  David G Parr; Berend C Stoel; Jan Stolk; Peter G Nightingale; Robert A Stockley
Journal:  Am J Respir Crit Care Med       Date:  2004-07-21       Impact factor: 21.405

10.  Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

Authors:  J P Sieren; J D Newell; P F Judy; D A Lynch; K S Chan; J Guo; E A Hoffman
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

View more
  4 in total

1.  A CT Scan Harmonization Technique to Detect Emphysema and Small Airway Diseases.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Raúl San Estépar José
Journal:  Image Anal Mov Organ Breast Thorac Images (2018)       Date:  2018-09-12

2.  Harmonization of chest CT scans for different doses and reconstruction methods.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Maria Jesus Ledesma-Carbayo; George R Washko; Raúl San José Estépar
Journal:  Med Phys       Date:  2019-06-07       Impact factor: 4.071

3.  Harmonization of in-plane resolution in CT using multiple reconstructions from single acquisitions.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Gabriel Ramos-Llordén; Raúl San José Estépar
Journal:  Med Phys       Date:  2021-09-14       Impact factor: 4.071

4.  Deep-learning-based direct inversion for material decomposition.

Authors:  Hao Gong; Shengzhen Tao; Kishore Rajendran; Wei Zhou; Cynthia H McCollough; Shuai Leng
Journal:  Med Phys       Date:  2020-10-30       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.