Complications of ilioischial reconstruction rings in revision total hip arthroplasty.

Stuart Goodman1, Hillary Saastamoinen, Nadav Shasha, Allan Gross.   

Abstract

The complications, management, and outcome of a consecutive series of 61 ilioischial reconstruction rings performed by 1 surgeon over a 15-year period are reported. Structural corticocancellous allografts were used in 48 cases. Twenty-seven cases had no complications, 9 had medical complications, and 5 had complications related to femoral revision. Other complications included 4 sciatic and 2 peroneal nerve palsies, 4 rings that lost fixation, 1 possibly loose ring, 3 fractured flanges, 3 loose cups, 7 dislocations, and 3 deep infections. Success, defined as a stable reconstruction with no further acetabular revision and bone graft incorporation, was 76%. We recommend a constrained acetabular liner to avoid dislocation in selected cases, slotting the ischial flange into bone for further ring stability and protection of the sciatic nerve.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15188101     DOI: 10.1016/j.arth.2003.11.015

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  39 in total

1.  Large acetabular defects can be managed with cementless revision components.

Authors:  E Scott Paxton; James A Keeney; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  CORR Insights(®): Custom Acetabular Cages Offer Stable Fixation and Improved Hip Scores for Revision THA With Severe Bone Defects.

Authors:  Thomas Jefferson Blumenfeld
Journal:  Clin Orthop Relat Res       Date:  2015-12-16       Impact factor: 4.176

3.  Section of the sciatic nerve by a metal acetabulum reinforcement ring: a literature review through one case.

Authors:  S Ruatti; M Grimaldi; D Saragaglia
Journal:  Eur J Orthop Surg Traumatol       Date:  2011-10-04

4.  [Revision implants of the future: trends and new developments].

Authors:  S Winkler; F-X Köck; C Baier; H-R Springorum; A Beifuss; P Lechler; J Grifka; J Schaumburger
Journal:  Orthopade       Date:  2012-01       Impact factor: 1.087

5.  Acetabular cage survival and analysis of factors related to failure.

Authors:  Jonathan N Sembrano; Edward Y Cheng
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

6.  Trabecular Metal cups for acetabular defects with 50% or less host bone contact.

Authors:  Dror Lakstein; David Backstein; Oleg Safir; Yona Kosashvili; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

7.  A review of the treatment of pelvic discontinuity.

Authors:  M Villanueva; A Rios-Luna; J Pereiro De Lamo; H Fahandez-Saddi; M P G Böstrom
Journal:  HSS J       Date:  2008-07-15

8.  Late fracture of a Burch-Schneider acetabular cage: rare occurrence following polyethylene cup wear.

Authors:  Dario Regis; Andrea Sandri; Alessandra Rizzo; Pietro Bartolozzi
Journal:  BMJ Case Rep       Date:  2009-03-26

Review 9.  Cementless acetabular revision: past, present, and future. Revision total hip arthroplasty: the acetabular side using cementless implants.

Authors:  Luis Pulido; Sridhar R Rachala; Miguel E Cabanela
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

10.  Osteogenic activity of locally applied small molecule drugs in a rat femur defect model.

Authors:  Jessica A Cottrell; Francis M Vales; Deborah Schachter; Scott Wadsworth; Rama Gundlapalli; Rasesh Kapadia; J Patrick O'Connor
Journal:  J Biomed Biotechnol       Date:  2010-06-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.