Literature DB >> 15052502

Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation.

H Greess1, J Lutze, A Nömayr, H Wolf, T Hothorn, W A Kalender, W Bautz.   

Abstract

The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as "very good," "good," "diagnostic" and "poor" in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. In general, no loss of image quality was observed. Measured noise showed a decrease up to 26% and an increase up to 36%, although there was no decrease of image quality. Online tube current modulation is now used as a standard in MSCT at our institution. Dose in MSCT examinations of children can be reduced substantially in routine examinations by online tube current modulation without a loss of image quality.

Entities:  

Mesh:

Year:  2004        PMID: 15052502     DOI: 10.1007/s00330-004-2301-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  14 in total

1.  Taking care of children: check out the parameters used for helical CT.

Authors:  L F Rogers
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

2.  [Clinical use of software-controlled x-ray tube modulation with "Smart-Scan" in spiral CT].

Authors:  K J Lehmann; J Wild; M Georgi
Journal:  Aktuelle Radiol       Date:  1997-05

3.  Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large Children's Hospital.

Authors:  L F Donnelly; K H Emery; A S Brody; T Laor; V M Gylys-Morin; C G Anton; S R Thomas; D P Frush
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

4.  Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey.

Authors:  G Brix; H D Nagel; G Stamm; R Veit; U Lechel; J Griebel; M Galanski
Journal:  Eur Radiol       Date:  2003-04-10       Impact factor: 5.315

5.  Radiation effective doses to patients undergoing abdominal CT examinations.

Authors:  D E Ware; W Huda; P J Mergo; A L Litwiller
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

6.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

7.  Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions.

Authors:  H Greess; H Wolf; U Baum; M Lell; M Pirkl; W Kalender; W A Bautz
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

8.  Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose).

Authors:  Holger Greess; Anton Nömayr; Heiko Wolf; Ulrich Baum; Michael Lell; Bernhard Böwing; Willi Kalender; Werner A Bautz
Journal:  Eur Radiol       Date:  2002-02-02       Impact factor: 5.315

Review 9.  [CT radiation exposure in children: Consequences of the American discussion for Europe].

Authors:  P Vock
Journal:  Radiologe       Date:  2002-09       Impact factor: 0.635

10.  Feasibility of high-resolution, low-dose chest CT in evaluating the pediatric chest.

Authors:  M M Ambrosino; N B Genieser; K J Roche; A Kaul; R M Lawrence
Journal:  Pediatr Radiol       Date:  1994
View more
  34 in total

1.  Influence of detector collimation on SNR in four different MDCT scanners using a reconstructed slice thickness of 5 mm.

Authors:  F R Verdun; A Noel; R Meuli; M Pachoud; P Monnin; J-F Valley; P Schnyder; A Denys
Journal:  Eur Radiol       Date:  2004-07-27       Impact factor: 5.315

2.  Pulmonary embolism: is multislice CT the method of choice? Against.

Authors:  Carl Schuemichen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-01       Impact factor: 9.236

Review 3.  Exposing the thyroid to radiation: a review of its current extent, risks, and implications.

Authors:  Bridget Sinnott; Elaine Ron; Arthur B Schneider
Journal:  Endocr Rev       Date:  2010-07-21       Impact factor: 19.871

4.  Comparative assessment of energy-mapping approaches in CT-based attenuation correction for PET.

Authors:  Mohammad R Ay; Maryam Shirmohammad; Saeed Sarkar; Arman Rahmim; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2011-02       Impact factor: 3.488

5.  Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT.

Authors:  Jessen Gurung; M Fawad Khan; Adel Maataoui; C Herzog; R Bux; H Bratzke; Hanns Ackermann; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

6.  The influences of tube voltage and scan direction on combined tube current modulation: a phantom study.

Authors:  Hyun Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-04-27

7.  Impact of the introduction of 16-row MDCT on image quality and patient dose: Phantom study and multi-centre survey.

Authors:  Francis R Verdun; Nicolas Theumann; Pierre-Alexandre Poletti; Daniel Gutierrez; Abbas Aroua; Pierre Schnyder; Jean-François Valley; Salah D Qanadli
Journal:  Eur Radiol       Date:  2006-08-29       Impact factor: 5.315

8.  Intraoperative computed tomography guidance to confirm decompression following endoscopic endonasal approach for cervicomedullary compression.

Authors:  Abhiram Gande; Matthew J Tormenti; Maria Koutourousiou; Alessandro Paluzzi; Juan C Fernendez-Miranda; Carl H Snydermnan; Paul A Gardner
Journal:  J Neurol Surg B Skull Base       Date:  2013-01-02

9.  The role of CT and MRI in the assessment of peripheral vascular disease.

Authors:  Franz von Ziegler; Marco A Costa
Journal:  Curr Cardiol Rep       Date:  2007-09       Impact factor: 2.931

10.  Effective dose estimation in whole-body multislice CT in paediatric trauma patients.

Authors:  Robin D Munk; Peter C Strohm; Ulrich Saueressig; Joern Zwingmann; Markus Uhl; Norbert P Südkamp; Elmar Kotter; Mathias Langer; Thorsten A Bley
Journal:  Pediatr Radiol       Date:  2009-01-16
View more