Literature DB >> 14752472

Day-to-day variability of global left ventricular functional and perfusional measurements by quantitative gated SPECT using Tc-99m tetrofosmin in patients with heart failure due to coronary artery disease.

Olivier De Winter1, Pieter De Bondt, Christophe Van De Wiele, Guy De Backer, Rudi A Dierckx, Johan De Sutter.   

Abstract

BACKGROUND: Although myocardial gated single photon emission computed tomography (SPECT) is routinely used for functional measurements in patients with coronary artery disease (CAD) and heart failure, day-to-day variability of left ventricular ejection fraction (LVEF), left ventricular (LV) volumes, and global perfusion scoring has not yet been investigated. METHODS AND
RESULTS: In 20 consecutive patients with CAD and an LVEF lower than 40% who routinely underwent a resting tetrofosmin gated SPECT study, we performed an additional gated SPECT study at rest 1 to 5 days later under the same circumstances. LV volumes and LVEF were calculated from the gated SPECT data by commercially available software (QGS). Myocardial perfusion was scored visually by use of a 20-segment, 5-point scoring method. For global LV function and perfusion, agreement between data was investigated by use of Bland-Altman plotting. The 95% limits of agreement found by Bland-Altman analysis were -0.9% +/- 6.0% for LVEF, 3 +/- 20 mL for LV end-diastolic volume, and 4 +/- 20 mL for LV end-systolic volume.
CONCLUSION: In CAD patients with an LVEF lower than 40%, day-to-day variability of measurements of global myocardial function and perfusion is quite similar to interobserver and intraobserver variability. Day-to-day variability of global LV functional parameters obtained by gated cardiac SPECT is fairly small, which indicates that myocardial gated SPECT can be used in daily clinical practice to determine changes in global LV function and perfusion over time in patients with diminished LV function.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14752472     DOI: 10.1016/j.nuclcard.2003.09.010

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  20 in total

1.  Measurements and day-to-day variabilities of left ventricular volumes and ejection fraction by three-dimensional echocardiography and comparison with magnetic resonance imaging.

Authors:  Y F Nosir; M H Lequin; J D Kasprzak; R T van Domburg; W B Vletter; J Yao; J Stoker; F J Ten Cate; J R Roelandt
Journal:  Am J Cardiol       Date:  1998-07-15       Impact factor: 2.778

2.  Comparison of post-stress ejection fraction and relative left ventricular volumes by automatic analysis of gated myocardial perfusion single-photon emission computed tomography acquired in the supine and prone positions.

Authors:  D Berman; G Germano; H Lewin; X Kang; P B Kavanagh; P Tapnio; M Harris; J Friedman
Journal:  J Nucl Cardiol       Date:  1998 Jan-Feb       Impact factor: 5.952

3.  Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI.

Authors:  E Vallejo; D P Dione; W L Bruni; R T Constable; P P Borek; J P Soares; J G Carr; S G Condos; F J Wackers; A J Sinusas
Journal:  J Nucl Med       Date:  2000-05       Impact factor: 10.057

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance.

Authors:  N G Bellenger; L C Davies; J M Francis; A J Coats; D J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  2000       Impact factor: 5.364

6.  Limited performance of quantitative assessment of myocardial function by thallium-201 gated myocardial single-photon emission tomography.

Authors:  D S Lee; J Y Ahn; S K Kim; B H Oh; J D Seo; J K Chung; M C Lee
Journal:  Eur J Nucl Med       Date:  2000-02

7.  Accuracy of left ventricular ejection fraction determined by gated myocardial perfusion SPECT with Tl-201 and Tc-99m sestamibi: comparison with first-pass radionuclide angiography.

Authors:  Z X He; E Cwajg; J S Preslar; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

8.  Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography.

Authors:  E C Vourvouri; D Poldermans; J J Bax; G Sianos; F B Sozzi; A F Schinkel; J de Sutter; G Parcharidis; R Valkema; J R Roelandt
Journal:  Eur J Nucl Med       Date:  2001-11

9.  Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study.

Authors:  D S Berman; H Kiat; J D Friedman; F P Wang; K van Train; L Matzer; J Maddahi; G Germano
Journal:  J Am Coll Cardiol       Date:  1993-11-01       Impact factor: 24.094

10.  Relationship of gated SPECT ventricular function parameters to angiographic measurements.

Authors:  K Nichols; J Tamis; E G DePuey; J Mieres; S Malhotra; A Rozanski
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

View more
  6 in total

1.  Incremental prognostic value of combined perfusion and function assessment during myocardial gated SPECT in patients aged 75 years or older.

Authors:  Olivier De Winter; Anja Velghe; Nico Van de Veire; Pieter De Bondt; Marc De Buyzere; Christophe Van De Wiele; Guy De Backer; Thierry C Gillebert; Rudi A Dierckx; Johan De Sutter
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

2.  Fractional flow reserve and myocardial viability as assessed by SPECT perfusion scintigraphy in patients with prior myocardial infarction.

Authors:  Branko Beleslin; Milan Dobric; Dragana Sobic-Saranovic; Vojislav Giga; Jelena Stepanovic; Ana Djordjevic-Dikic; Milan Nedeljkovic; Sinisa Stojkovic; Vladan Vukcevic; Goran Stankovic; Dejan Orlic; Zorica Petrasinovic; Smiljana Pavlovic; Vladimir Obradovic; Miodrag Ostojic
Journal:  J Nucl Cardiol       Date:  2010-06-04       Impact factor: 5.952

3.  Reliability of myocardial perfusion gated SPECT for the reproducible evaluation of resting left ventricular functional parameters in long-term follow-up.

Authors:  Roberto Sciagrà; Valentina Berti; Sabrina Genovese; Alberto Pupi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

4.  Relationship between infarct size and severity measured by gated SPECT and long-term left ventricular remodelling after acute myocardial infarction.

Authors:  Valentina Berti; Roberto Sciagrà; Wanda Acampa; Francesca Ricci; Giampaolo Cerisano; Rosj Gallicchio; Carlo Vigorito; Alberto Pupi; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-02-15       Impact factor: 9.236

5.  Low-dose single acquisition rest (99m)Tc/stress (201)Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation.

Authors:  Thomas Dey; Barbra E Backus; R Leo Romijn; Herfried Wieczorek; J Fred Verzijlbergen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-09-13       Impact factor: 9.236

Review 6.  The expanding role of left ventricular functional assessment using gated myocardial perfusion SPECT: the supporting actor is stealing the scene.

Authors:  Roberto Sciagrà
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07       Impact factor: 10.057

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.