Literature DB >> 10755724

Limited performance of quantitative assessment of myocardial function by thallium-201 gated myocardial single-photon emission tomography.

D S Lee1, J Y Ahn, S K Kim, B H Oh, J D Seo, J K Chung, M C Lee.   

Abstract

We investigated the reproducibility between thallium-201 and technetium-99m methoxyisobutylisonitrile (MIBI) gated single-photon emission tomography (SPET) for the assessment of indices of myocardial function such as end-diastolic and end-systolic volume (EDV, ESV), ejection fraction (EF) and wall motion. Rest 201Tl (111 MBq) gated SPET was sequentially performed twice in 20 patients. Rest 201Tl gated SPET and rest 99mTc-MIBI (370 MBq) gated SPET were performed 24 h apart in 40 patients. Wall motion was graded using the surface display of the Cedars quantitative gated SPET (QGS) software. EDV, ESV and EF were also measured using the QGS software. The reproducibility of functional assessment on rest 201Tl gated SPET was compared with that on 99mTc-MIBI gated SPET, and also with that between 201Tl gated SPET and 99mTc-MIBI gated SPET performed on the next day. The two standard deviation (2 SD) values for EDV, ESV and EF on the Bland-Altman plot were 29 ml, 19 ml and 12%, respectively, on repeated 201Tl gated SPET, compared with 14 ml, 11 ml and 5.3% on repeated 99mTc-MIBI gated SPET. The correlations were good (r=0.96, 0.97 and 0.87) between the two measurements of EDV, ESV and EF on repeated rest studies with 201Tl and 99mTc-MIBI gated SPET. However, Bland-Altman analysis revealed that the 2 SD values between the two measurements were 31 ml, 23 ml and 12%. We were able to score the wall motion in all cases using the 3D surface display of the QGS on 201Tl gated SPET. The kappa value of the wall motion grade on the repeated 201Tl study was 0.35, while that of the wall motion grade on the repeated 99mTc-MIBI study was 0.76. The kappa value was 0.49 for grading of wall motion on repeated rest studies with 201Tl and 99mTc-MIBI. In conclusion, QGS helped determine EDV, ESV, EF and wall motion on 201Tl gated SPET. Because the EDV, ESV and EF were less reproducible on repeated 201Tl gated SPET or on 201Tl gated SPET and 99mTc-MIBI gated SPET on the next day than on repeated 99mTc-MIBI gated SPET, functional measurement on 201Tl gated SPET did not seem to be interchangeable with that on 99mTc-MIBI gated SPET.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10755724     DOI: 10.1007/s002590050025

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  16 in total

1.  Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Authors:  Doumit Daou; Didier Vilain; Patrice Colin; Rachida Lebtahi; Thierry Fourme; Carlos Coaguila; Abdel Benada; Ilana Idy-Peretti; Michel Slama; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

2.  Day-to-day variability of global left ventricular functional and perfusional measurements by quantitative gated SPECT using Tc-99m tetrofosmin in patients with heart failure due to coronary artery disease.

Authors:  Olivier De Winter; Pieter De Bondt; Christophe Van De Wiele; Guy De Backer; Rudi A Dierckx; Johan De Sutter
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

Review 3.  Measurement of ventricular function with radionuclide techniques.

Authors:  Kim A Williams
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

4.  Multicenter intercomparison assessment of consistency of left ventricular function from a gated cardiac SPECT phantom.

Authors:  Hein J Verberne; Petra Dibbets-Schneider; Astrid Spijkerboer; Marcel Stokkel; Berthe L F van Eck-Smit; Ellinor Busemann Sokole
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 5.  Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

Review 6.  Gated SPECT in assessment of regional and global left ventricular function: an update.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Piotr Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2013-12       Impact factor: 5.952

7.  Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis.

Authors:  Chisato Kondo; Kenji Fukushima; Kiyoko Kusakabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

8.  Reliability of myocardial perfusion gated SPECT for the reproducible evaluation of resting left ventricular functional parameters in long-term follow-up.

Authors:  Roberto Sciagrà; Valentina Berti; Sabrina Genovese; Alberto Pupi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

9.  Evaluation of immediate post-stress wall motion on adenosine stress/rest thallium-201 gated myocardial SPECT.

Authors:  Won Woo Lee; Eun Kyung Park; Jae Seon Eo; Sang Woo Lee; Cheol Ho Kim; Young So; Dong Soo Lee; June-Key Chung; Myung Chul Lee; Sang Eun Kim
Journal:  Int J Cardiovasc Imaging       Date:  2005-08-18       Impact factor: 2.357

10.  Stress-related variations in left ventricular function as assessed with gated myocardial perfusion SPECT.

Authors:  Hein J Verberne; Marcel G W Dijkgraaf; G Aernout Somsen; Berthe L F van Eck-Smit
Journal:  J Nucl Cardiol       Date:  2003 Sep-Oct       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.