Literature DB >> 10809204

Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI.

E Vallejo1, D P Dione, W L Bruni, R T Constable, P P Borek, J P Soares, J G Carr, S G Condos, F J Wackers, A J Sinusas.   

Abstract

UNLABELLED: Quantitative gated SPECT (QGS) has been used for computation of left ventricular volumes and ejection fraction. This study evaluated, first, the effect of injected dose, time of imaging, and background activity on the reproducibility of QGS and, second, the accuracy of QGS, compared with cine MRI, for determining left ventricular volumes and ejection fractions in dogs with and without perfusion defects.
METHODS: Sixteen dogs were subjected to either chronic occlusion of the circumflex artery (group I, no perfusion defect) or acute occlusion of the anterior descending coronary artery (group II, perfusion defect). Both groups underwent serial MRI and SPECT.
RESULTS: ( QGS was very reproducible using the automated program (r = 0.99997). Correlation between left ventricular ejection fraction (LVEF) at 15 and 45 min was poor after the low-dose injection (r = 0.54; SE = 9%) and only fair after the high-dose injection (r = 0.77; SE = 5%). Correlation was poor in the presence of significant background activity (r = 0.36; SE = 12%). Correlation between QGS left ventricular volumes and MRI was good for group I (end-diastolic volume, r = 0.86; end-systolic volume, r = 0.81) and only fair for group II (end-diastolic volume, r = 0.66; end-systolic volume, r = 0.69). The overall LVEF correlation between QGS and MRI was poor (r = 0.51). QGS LVEF (mean +/- SD, 42% +/- 3%) overestimated MRI LVEF (29% +/- 2%).
CONCLUSION: QGS provides a highly reproducible estimate of LVEF. However, QGS is affected by changes in background activity, time of imaging, and injected dose. In the presence of perfusion defects, QGS overestimated volume relative to MRI. The correlation between QGS- and MRI-derived LVEF was poor in this canine model.

Entities:  

Mesh:

Year:  2000        PMID: 10809204

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  27 in total

1.  Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods.

Authors:  T L Faber; J P Vansant; R I Pettigrew; J R Galt; M Blais; G Chatzimavroudis; C D Cooke; R D Folks; S M Waldrop; E Gurtler-Krawczynska; M D Wittry; E V Garcia
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

2.  Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Authors:  Doumit Daou; Didier Vilain; Patrice Colin; Rachida Lebtahi; Thierry Fourme; Carlos Coaguila; Abdel Benada; Ilana Idy-Peretti; Michel Slama; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

3.  Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT.

Authors:  Enrique Vallejo; Hugo Chaya; Gerardo Plancarte; Diana Victoria; David Bialostozky
Journal:  J Nucl Cardiol       Date:  2002 Jul-Aug       Impact factor: 5.952

4.  Day-to-day variability of global left ventricular functional and perfusional measurements by quantitative gated SPECT using Tc-99m tetrofosmin in patients with heart failure due to coronary artery disease.

Authors:  Olivier De Winter; Pieter De Bondt; Christophe Van De Wiele; Guy De Backer; Rudi A Dierckx; Johan De Sutter
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

5.  Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction.

Authors:  Sachin M Navare; Frans J T Wackers; Yi-Hwa Liu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-28       Impact factor: 9.236

6.  A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom.

Authors:  Jacco J N Visser; Ellinor Busemann Sokole; Hein J Verberne; Jan B A Habraken; Huybert J F van de Stadt; Joris E N Jaspers; Morgan Shehata; Paul M Heeman; Berthe L F van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

7.  Software-dependent processing variability in SPECT functional parameters: Clinical implications.

Authors:  Saurabh Malhotra; Prem Soman
Journal:  J Nucl Cardiol       Date:  2016-02-17       Impact factor: 5.952

8.  Multicenter intercomparison assessment of consistency of left ventricular function from a gated cardiac SPECT phantom.

Authors:  Hein J Verberne; Petra Dibbets-Schneider; Astrid Spijkerboer; Marcel Stokkel; Berthe L F van Eck-Smit; Ellinor Busemann Sokole
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

9.  Quantification of nuclear cardiac images: the Yale approach.

Authors:  Yi-Hwa Liu
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

10.  Has LVEF changed beyond chance? Limits of agreement of radiotracer-derived LVEF.

Authors:  Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.