Literature DB >> 12955478

Transpedicular screwing of the seventh cervical vertebra: anatomical considerations and surgical technique.

C Barrey1, F Cotton, J Jund, P Mertens, G Perrin.   

Abstract

The purpose of this study was first to assess the feasibility of C7 transpedicular screwing with a morphological study and secondly to evaluate the safety of such a surgical technique when guided only by posterior landmarks. Eighteen C7 vertebrae, harvested from fresh human cadavers, were included in this study. First the morphometry of C7 pedicle was performed on computed tomography with multiplanar reconstructions. Results of this quantitative anatomy were compared with the literature data. Secondly 30 pedicle screws, whose placement was guided only by anatomical features on the posterior face of the dorsal arch, were inserted in 15 C7 vertebrae. A second computed tomographic examination was done after the surgical procedure to check the screw placement in both planes. The average pedicular width was 6+/-1.2 mm and the average height was 5.8+/-1.1 mm. The pedicle angulation in the transverse plane was 33.3 degrees +/-6.6 degrees, the pedicle angulation in the sagittal plane was 4.3 degrees +/-4.5 degrees downward with reference to the lower endplate of C7. The average distance from the entry point of transpedicular screwing to the anterior cortex of the vertebral body was 29+/-3 mm. Concerning the safety of transpedicular screwing, 63% of screws were found entirely inside the pedicle without any violation of the pedicle cortex. Most of pedicle violations were observed in the transverse plane. No grade II violation of the pedicle was observed. Dimensions of the C7 pedicle are amply compatible with transpedicular fixation using 3.5 mm screws. Such a surgical technique seems to be an interesting option when posterior fixation of C7 is required. Nevertheless morphological guidelines appeared not to be sufficient to ensure safe transpedicular screwing. Laminoforaminotomy is strongly recommended, although it has not been evaluated in this study.

Entities:  

Mesh:

Year:  2003        PMID: 12955478     DOI: 10.1007/s00276-003-0163-5

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  21 in total

1.  One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems.

Authors:  K Abumi; K Kaneda; Y Shono; M Fujiya
Journal:  J Neurosurg       Date:  1999-01       Impact factor: 5.115

Review 2.  Transpedicle screw fixation of the cervical spine.

Authors:  S C Ludwig; D L Kramer; A R Vaccaro; T J Albert
Journal:  Clin Orthop Relat Res       Date:  1999-02       Impact factor: 4.176

3.  Cervical spine pedicle screws: a biomechanical comparison of two insertion techniques.

Authors:  J M Kowalski; S C Ludwig; W C Hutton; J G Heller
Journal:  Spine (Phila Pa 1976)       Date:  2000-11-15       Impact factor: 3.468

4.  Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance.

Authors:  M Kamimura; S Ebara; H Itoh; Y Tateiwa; T Kinoshita; K Takaoka
Journal:  J Spinal Disord       Date:  2000-06

5.  Accuracy of cervical pedicle screw placement using the funnel technique.

Authors:  E E Karaikovic; W Yingsakmongkol; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  2001-11-15       Impact factor: 3.468

6.  The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation.

Authors:  N A Ebraheim; R Xu; R A Yeasting
Journal:  Spine (Phila Pa 1976)       Date:  1996-06-01       Impact factor: 3.468

7.  Morphologic characteristics of human cervical pedicles.

Authors:  E E Karaikovic; M D Daubs; R W Madsen; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  1997-03-01       Impact factor: 3.468

8.  Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison.

Authors:  E L Jones; J G Heller; D H Silcox; W C Hutton
Journal:  Spine (Phila Pa 1976)       Date:  1997-05-01       Impact factor: 3.468

9.  Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine.

Authors:  Y Kotani; B W Cunningham; K Abumi; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-15       Impact factor: 3.468

10.  Pedicle screw fixation for nontraumatic lesions of the cervical spine.

Authors:  K Abumi; K Kaneda
Journal:  Spine (Phila Pa 1976)       Date:  1997-08-15       Impact factor: 3.468

View more
  16 in total

1.  C7 posterior fixation using intralaminar screws : early clinical and radiographic outcome.

Authors:  Sang Hoon Jang; Jae Taek Hong; Il Sup Kim; In Sung Yeo; Byung Chul Son; Sang Won Lee
Journal:  J Korean Neurosurg Soc       Date:  2010-08-31

2.  The use of pedicle screw-rod system for the posterior fixation in cervico-thoracic junction.

Authors:  Wonik Cho; Ahmed Shawky Eid; Ung-Kyu Chang
Journal:  J Korean Neurosurg Soc       Date:  2010-07-31

3.  Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique.

Authors:  Shaunak Desai; Anil Sethi; Christopher C Ninh; Stephen Bartol; Rahul Vaidya
Journal:  Eur Spine J       Date:  2010-07-17       Impact factor: 3.134

4.  The C7 pedicle as a superior fixation point in spinal stabilization for spinal metastatic disease.

Authors:  Harjot Thind; Andrew J Fabiano
Journal:  J Spine Surg       Date:  2018-03

5.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

6.  The ipsilateral lamina-pedicle angle: can it be used to guide pedicle screw placement in the sub-axial cervical spine?

Authors:  Edward Bayley; Zergham Zia; Robert Kerslake; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2009-09-01       Impact factor: 3.134

7.  Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy.

Authors:  Dae-Jean Jo; Eun-Min Seo; Ki-Tack Kim; Sung-Min Kim; Sang-Hun Lee
Journal:  J Korean Neurosurg Soc       Date:  2012-11-30

8.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

9.  A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study.

Authors:  Muhammad Qasim; Jae Taek Hong; Raghu N Natarajan; Howard S An
Journal:  J Korean Neurosurg Soc       Date:  2013-06-30

10.  Morphometric analysis of the seventh cervical vertebra for pedicle screw insertion.

Authors:  Wensheng Liao; Liangbing Guo; Heng Bao; Limin Wang
Journal:  Indian J Orthop       Date:  2015 May-Jun       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.