Literature DB >> 10872759

Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance.

M Kamimura1, S Ebara, H Itoh, Y Tateiwa, T Kinoshita, K Takaoka.   

Abstract

We used a commercially available computer-assisted image-guidance system for cervical pedicle screw insertion in both the laboratory and in a preliminary clinical setting. Nine plastic cervical spine models (C2-C7) were used in the laboratory test. The StealthStation was used to create the preoperative plan for each screw such that it would be inserted down the center of the pedicle, parallel to the long axis. Using a light-emitting diode-equipped drill guide, 2-mm holes were drilled in 108 pedicles. A total of 108 pedicle holes were drilled. The mean trajectory deviation from the surgical plan in the axial plane was 1.7+/-1.7 degrees (range, 0 to 8 degrees), and the mean deviation of the position of the hole was 1.7+/-0.6 mm (range, 0.1 to 2.9 mm). Eighty-three drill holes (76.9%) were contained within the pedicles, whereas partial cortical perforation was noted in 25 pedicles (23.1%). In the clinical setting, 36 cervical pedicle screws were inserted in nine patients using the image-guided system. Within the limits of imaging artifact, all 36 pedicle screws appear to have been inserted accurately by postoperative computed tomographic examination. No neurologic or vascular complications were encountered.

Entities:  

Mesh:

Year:  2000        PMID: 10872759     DOI: 10.1097/00002517-200006000-00004

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  28 in total

1.  3D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screws.

Authors:  J-S Jarvers; S Katscher; A Franck; S Glasmacher; C Schmidt; T Blattert; C Josten
Journal:  Eur J Trauma Emerg Surg       Date:  2011-04-01       Impact factor: 3.693

2.  An evaluation of image-guided technologies in the placement of anterior thoracic vertebral body screws in spinal trauma: a cadaver study.

Authors:  Alexander R Vaccaro; Philip S Yuan; Harvey E Smith; Jonathon Hott; Rick Sasso; Stephen Papadopoulos
Journal:  J Spinal Cord Med       Date:  2005       Impact factor: 1.985

3.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

4.  Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance.

Authors:  Eric W Nottmeier; Andrew B Foy
Journal:  Eur Spine J       Date:  2007-11-22       Impact factor: 3.134

Review 5.  Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature.

Authors:  M Reinhold; C Bach; L Audigé; R Bale; R Attal; M Blauth; F Magerl
Journal:  Eur Spine J       Date:  2008-01-22       Impact factor: 3.134

6.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

7.  The ipsilateral lamina-pedicle angle: can it be used to guide pedicle screw placement in the sub-axial cervical spine?

Authors:  Edward Bayley; Zergham Zia; Robert Kerslake; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2009-09-01       Impact factor: 3.134

Review 8.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

9.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

10.  A novel computer-assisted drill guide template for placement of C2 laminar screws.

Authors:  Sheng Lu; Yong Q Xu; Yuan Z Zhang; Le Xie; Hai Guo; Dong P Li
Journal:  Eur Spine J       Date:  2009-06-11       Impact factor: 3.134

View more