Literature DB >> 12934205

Third-body wear of highly cross-linked polyethylene in a hip simulator.

Charles R Bragdon1, Murali Jasty, Orhun K Muratoglu, Daniel O O'Connor, William H Harris.   

Abstract

The wear performance of a radiation cross-linked melted ultrahigh-molecular-weight polyethylene (UHMWPE) articulating against 28-mm cobalt chrome femoral heads in the presence of third-body particulate debris was investigated in a hip simulator and compared with the wear of conventional UHMWPE. Particles of aluminum oxide or bone cement containing barium sulfate were added to the serum. In the presence of aluminum oxide particles, the incremental wear rates of conventional UHMWPE averaged as high as 149 +/- 116 mg/million cycles compared with 37 +/- 38 mg/million cycles for the highly cross-linked components. The difference in the average weight loss was statistically significant at P <.01. With bone cement particles, the conventional UHMWPE components had an average incremental wear rate of 19 +/- 5mg/million cycles, and the wear rate of the highly cross-linked UHMWPE components was 0.5 +/- 0.7 mg/million cycles.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12934205     DOI: 10.1016/s0883-5403(03)00146-3

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  20 in total

1.  Effects of episodic subluxation events on third body ingress and embedment in the THA bearing surface.

Authors:  Anneliese D Heiner; Hannah J Lundberg; Thomas E Baer; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2008-06-17       Impact factor: 2.712

2.  Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study.

Authors:  Zoran Bascarevic; Zoran Vukasinovic; Nemanja Slavkovic; Borislav Dulic; Goran Trajkovic; Violeta Bascarevic; Sladjan Timotijevic
Journal:  Int Orthop       Date:  2009-11-01       Impact factor: 3.075

3.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

4.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

5.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

6.  Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Authors:  Mohamed E Moussa; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-11-11       Impact factor: 4.757

7.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

8.  Sliding direction dependence of polyethylene wear for metal counterface traverse of severe scratches.

Authors:  Liam P Glennon; Thomas E Baer; James A Martin; William D Lack; Thomas D Brown
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

9.  Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years.

Authors:  Paul F Lachiewicz; Daniel S Heckman; Elizabeth S Soileau; Jimmi Mangla; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

10.  Long-Term Results of Total Hip Arthroplasty with 28-Millimeter Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.

Authors:  Jeffrey B Stambough; Gail Pashos; Frank C Bohnenkamp; William J Maloney; John M Martell; John C Clohisy
Journal:  J Arthroplasty       Date:  2015-07-17       Impact factor: 4.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.