Literature DB >> 26260785

Long-Term Results of Total Hip Arthroplasty with 28-Millimeter Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.

Jeffrey B Stambough1, Gail Pashos1, Frank C Bohnenkamp2, William J Maloney3, John M Martell4, John C Clohisy1.   

Abstract

Highly cross-linked polyethylene (HXLPE) is the most commonly used bearing surface in total hip arthroplasty (THA) because of its superior wear properties, but long-term results in young patients are limited. We report on the clinical outcome, radiographic wear patterns and survivorship of 72 patients ≤50 years old who had a 28-millimeter cobalt-chromium femoral head on HXLPE acetabular liner. Mean and median true linear wear rates at average ten-year follow-up were 0.0104 and 0.01 mm per year ± 0.07 mm. Mean and median two-dimensional volumetric wear rates were 12.79 mm(3) and 5.834 mm(3) per year ± 26.1mm(3) as determined by Martell analysis. As a result of the minimal wear profile, there was no evidence of radiographic osteolysis and no wear-related revisions.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Martell method; THA survivorship; highly cross-linked polyethylene; linear and volumetric wear

Mesh:

Substances:

Year:  2015        PMID: 26260785      PMCID: PMC4761425          DOI: 10.1016/j.arth.2015.07.025

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  52 in total

1.  Reassessment of computerized wear measurement for total hip arthroplasty with correction for projectional image distortion: a brief follow-up report.

Authors:  Matthew J Kraay; Rebecca D Moore; John M Martell; Clare M Rimnac
Journal:  J Bone Joint Surg Am       Date:  2010-08-04       Impact factor: 5.284

2.  Indications and results of hip resurfacing.

Authors:  D J W McMinn; J Daniel; H Ziaee; C Pradhan
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

3.  Metal-on-metal hip arthroplasty in patients thirty years of age or younger.

Authors:  Julien Girard; Donatien Bocquet; Guillaume Autissier; Nicolas Fouilleron; Damien Fron; Henri Migaud
Journal:  J Bone Joint Surg Am       Date:  2010-10-20       Impact factor: 5.284

4.  Metal-on-metal hip resurfacing in osteonecrosis of the femoral head.

Authors:  Matthew P Revell; Callum W McBryde; Sharad Bhatnagar; Paul B Pynsent; Ronan B C Treacy
Journal:  J Bone Joint Surg Am       Date:  2006-11       Impact factor: 5.284

5.  The effect of cup placement in cementless total hip arthroplasty on the wear rate of polyethylene.

Authors:  Masayuki Ito; Kunihiko Tokunaga; Naoto Endo; Yuhichi Takano; Nobuhiro Yuasa
Journal:  Orthopedics       Date:  2008-03       Impact factor: 1.390

6.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

7.  Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years.

Authors:  Paul F Lachiewicz; Daniel S Heckman; Elizabeth S Soileau; Jimmi Mangla; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

8.  The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Authors:  Donald S Garbuz; Michael Tanzer; Nelson V Greidanus; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2009-08-21       Impact factor: 4.176

9.  Patient compliance with clinical follow-up after total joint arthroplasty.

Authors:  John C Clohisy; Ganesh V Kamath; Gregory D Byrd; Karen Steger-May; Rick W Wright
Journal:  J Bone Joint Surg Am       Date:  2008-09       Impact factor: 5.284

Review 10.  Hip resurfacing arthroplasty: the Australian experience.

Authors:  Martin L Buergi; William L Walter
Journal:  J Arthroplasty       Date:  2007-10       Impact factor: 4.757

View more
  7 in total

1.  Bousquet dual mobility socket for patient under fifty years old. More than twenty year follow-up of one hundred and thirty one hips.

Authors:  Remi Philippot; Thomas Neri; Bertrand Boyer; Brice Viard; Frederic Farizon
Journal:  Int Orthop       Date:  2017-01-16       Impact factor: 3.075

2.  Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature

Authors:  Xin Yu Mei; Ying Jia Gong; Oleg Safir; Allan Gross; Paul Kuzyk
Journal:  Can J Surg       Date:  2019-08-01       Impact factor: 2.089

3.  Gender Differences in Wear Rates for 28- vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty.

Authors:  Jeffrey B Stambough; Gail Pashos; Ningying Wu; Jacob A Haynes; John M Martell; John C Clohisy
Journal:  J Arthroplasty       Date:  2015-10-28       Impact factor: 4.757

4.  Radiographic evaluation of linear wear of bipolar hemiarthroplasty devices in vivo.

Authors:  Nobuhiro Kaku; Shouhei Noda; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2018-07-20

5.  Tribology of total hip arthroplasty prostheses: What an orthopaedic surgeon should know.

Authors:  Claude B Rieker
Journal:  EFORT Open Rev       Date:  2017-03-13

6.  Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels.

Authors:  Omaima I Abdel Hamid; Mohamed E Attia; Jon M Hirshon; Mohamed El-Shinawi; Moustafa El-Hussaini; Maged El-Setouhy
Journal:  Drug Healthc Patient Saf       Date:  2022-07-18

7.  Mid-term results of total hip replacement with subtrochanteric osteotomy, modular stem, and ceramic surface in Crowe IV hip dysplasia.

Authors:  Sen Wang; Yonggang Zhou; Haiyang Ma; Yinqiao Du; Shang Piao; Wenming Wu
Journal:  Arthroplast Today       Date:  2017-11-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.