Literature DB >> 23052851

[Principles of tribological analysis of endoprostheses].

J P Kretzer1, C Zietz, C Schröder, J Reinders, L Middelborg, A Paulus, R Sonntag, R Bader, S Utzschneider.   

Abstract

For the tribological characterization of artificial joints, various experimental methods are currently available. However, the in vitro test conditions applied are only comparable in a limited way and transferability to the in vivo situation is also restricted. This is due to the different wear simulation concepts used and partly insufficient simulation of clinical worst case situations. In the present paper current scientific methods and procedures for tribological testing of artificial joints are presented. In addition, the biological effects of wear products are described enabling clinicians to challenge tribological studies and to facilitate specific interpretation of scientific results taking the clinical situation into account.

Entities:  

Mesh:

Year:  2012        PMID: 23052851     DOI: 10.1007/s00132-012-1948-1

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  57 in total

1.  Third-body wear of highly cross-linked polyethylene in a hip simulator.

Authors:  Charles R Bragdon; Murali Jasty; Orhun K Muratoglu; Daniel O O'Connor; William H Harris
Journal:  J Arthroplasty       Date:  2003-08       Impact factor: 4.757

2.  Wear of contemporary total knee replacements--a knee simulator study of six current designs.

Authors:  Sandra Utzschneider; Norbert Harrasser; Christian Schroeder; Farhad Mazoochian; Volkmar Jansson
Journal:  Clin Biomech (Bristol, Avon)       Date:  2009-05-17       Impact factor: 2.063

Review 3.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

4.  Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo.

Authors:  Sandra Utzschneider; Fabian Becker; Thomas M Grupp; Birte Sievers; Alexander Paulus; Oliver Gottschalk; Volkmar Jansson
Journal:  Acta Biomater       Date:  2010-06-08       Impact factor: 8.947

5.  Effects of soluble metals on human peri-implant cells.

Authors:  Nadim James Hallab; Shelley Anderson; Marco Caicedo; Amee Brasher; Katalin Mikecz; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2005-07-01       Impact factor: 4.396

6.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

7.  Wear of polyethylene against oxidized zirconium femoral components effect of aggressive kinematic conditions and malalignment in total knee arthroplasty.

Authors:  Kace A Ezzet; Juan C Hermida; Nikolai Steklov; Darryl D D'Lima
Journal:  J Arthroplasty       Date:  2011-09-09       Impact factor: 4.757

8.  2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.

Authors:  C Anderson Engh; Steven J MacDonald; Supatra Sritulanondha; Abigail Thompson; Douglas Naudie; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

9.  Characterization of the running-in period in total hip resurfacing arthroplasty: an in vivo and in vitro metal ion analysis.

Authors:  Christian Heisel; Nikolaus Streich; Michael Krachler; Eike Jakubowitz; J Philippe Kretzer
Journal:  J Bone Joint Surg Am       Date:  2008-08       Impact factor: 5.284

10.  Risk factors for inflammatory pseudotumour formation following hip resurfacing.

Authors:  S Glyn-Jones; H Pandit; Y-M Kwon; H Doll; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2009-12
View more
  5 in total

1.  [Supramacroparticulate polyethylene in inflammation of synovial-like interface membranes: Characterization and suggested nomenclature].

Authors:  V Krenn; F Hopf; P Thomas; M Thomsen; S Usbeck; F Boettner; S Müller; D Saberi; T Hügle; M Huber; L Scheuber; J C Hopf; J P Kretzer
Journal:  Orthopade       Date:  2016-03       Impact factor: 1.087

2.  [Histopathological particle algorithm. Particle identification in the synovia and the SLIM].

Authors:  V Krenn; P Thomas; M Thomsen; J P Kretzer; S Usbeck; L Scheuber; G Perino; W Rüther; R v Welser; F Hopf; M Huber
Journal:  Z Rheumatol       Date:  2014-09       Impact factor: 1.372

Review 3.  [Possibilities and limits of modern polyethylenes. With respect to the application profile].

Authors:  S Utzschneider; A C Paulus; C Schröder; V Jansson
Journal:  Orthopade       Date:  2014-06       Impact factor: 1.087

4.  Comparison of Different Locking Mechanisms in Total Hip Arthroplasty: Relative Motion between Cup and Inlay.

Authors:  Sebastian Jaeger; Maximilian Uhler; Stefan Schroeder; Nicholas A Beckmann; Steffen Braun
Journal:  Materials (Basel)       Date:  2020-03-19       Impact factor: 3.623

5.  Rheologic Behavior of Bovine Calf Serum.

Authors:  Tanja Wonerow; Maximilian Uhler; Jens Nuppnau; J Philippe Kretzer; Frank Mantwill
Journal:  Materials (Basel)       Date:  2021-05-13       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.