Corneal thickness values before and after oxybuprocaine 0.4% eye drops.

Isabel Asensio1, Saleh M Rahhal, Luis Alonso, José M Palanca-Sanfrancisco, Juan A Sanchis-Gimeno.   

Abstract

PURPOSE: To determine changes in corneal thickness after topical anesthesia.
METHODS: Corneal thickness was measured before and 3 minutes after administration of two drops of oxybuprocaine 0.4% to 26 patients (26 eyes). We analyzed the corneal thickness of a control group, which was made up of 26 patients (26 eyes) before and 3 minutes after administration of two drops of saline solution. Corneal thickness was measured with the Orbscan Topography System II (Bausch Lomb Surg., Barcelona).
RESULTS: Variations higher than +/- 10 microm were found following the instillation of 2 oxybuprocaine eye drops in eight eyes (30.76%) at the inferonasal cornea, in six eyes (23.08%) at the superotemporal, temporal and inferotemporal cornea, in five eyes (19.23%) at the nasal cornea, in three eyes (11.53%) at the central cornea, and in two eyes (7.69%) at the superonasal cornea. Nevertheless, no significant differences in the mean corneal thickness at each corneal location between the first and the second corneal thickness measurements were found in anesthetized eyes.
CONCLUSIONS: Some individuals can present important increases and decreases in corneal thickness values after anesthetic eye drops. This effect of anesthetic eye drops must be considered by refractive surgeons when carrying out preoperative laser in situ keratomileusis corneal thickness measurements.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12883345     DOI: 10.1097/00003226-200308000-00008

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  14 in total

1.  [Effect of applanation tonometry on precision of biometry measurements].

Authors:  T M Rabsilber; S Bueltmann; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-01       Impact factor: 1.059

2.  Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry.

Authors:  Hani S Al-Mezaine; Saleh A Al-Amro; Dustan Kangave; Abdulkareem Sadaawy; Taher A Wehaib; Saleh Al-Obeidan
Journal:  Int Ophthalmol       Date:  2007-09-26       Impact factor: 2.031

3.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

4.  Evaluation of rebound tonometry in non-human primates.

Authors:  Elizabeth J Elsmo; Julie A Kiland; Paul L Kaufman; Gillian J McLellan
Journal:  Exp Eye Res       Date:  2011-02-16       Impact factor: 3.467

5.  Eye rubbing-induced changes in intraocular pressure and corneal thickness measured at five locations, in subjects with ocular allergy.

Authors:  Uchechukwu L Osuagwu; Saud A Alanazi
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

6.  The effect of topical anesthesia on the rat electroretinogram.

Authors:  Shai Sandalon; Ron Ofri
Journal:  Doc Ophthalmol       Date:  2008-07-30       Impact factor: 2.379

7.  Clinical investigation of the effect of topical anesthesia on intraocular pressure.

Authors:  Turki M Almubrad; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2007-09

8.  A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

Authors:  Derek Nankivil; Alex Gonzalez; Esdras Arrieta; Cornelis Rowaan; Mariela C Aguilar; Krystal Sotolongo; Florence A Cabot; Sonia H Yoo; Jean-Marie A Parel
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-19       Impact factor: 4.799

9.  Central corneal thickness measured by the Orbscan II system, contact ultrasound pachymetry, and the Artemis 2 system.

Authors:  Tania Paul; Mira Lim; Christopher E Starr; Harriet O Lloyd; D Jackson Coleman; Ronald H Silverman
Journal:  J Cataract Refract Surg       Date:  2008-11       Impact factor: 3.351

10.  Effect of tetracaine on intraocular pressure in normal and hypertensive rabbit eyes.

Authors:  Ali Asghar Sarchahi; Hooman Bozorgi
Journal:  J Ophthalmic Vis Res       Date:  2012-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.