Literature DB >> 12845483

Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

E H van Haaren1, I C Heyligers.   

Abstract

Radiographs of 72 uncemented hip implants with a mean follow-up of 6.5 years were analysed to measure wear of the implant. The wear rate was measured using the modified technique of Livermore and was found to be 0.13 mm per year (CI 95% 0.080-0.18). There was no statistical correlation between wear and age, gender and cup angle, but there was a correlation between wear and the number and size of cysts. This has not been previously published. In view of the risk of loosening and of a dramatic increase in the rate of wear when the femoral head articulates with the metal backing, it is important to plan revision of these cups in good time and to ensure regular radiographic surveillance of these patients.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12845483      PMCID: PMC3461862          DOI: 10.1007/s00264-003-0479-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  15 in total

1.  Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of 85 Landos Atoll arthroplasties.

Authors:  Kuo-An Lai; Wun-Jer Shen; Chyun-Hsiang Chen; Chyun-Yu Yang; Wen-Pin Hu; Guang-Liang Chang
Journal:  J Bone Joint Surg Br       Date:  2002-07

2.  Hydroxylapatite-coated hip implants. Multicenter three-year clinical and roentgenographic results.

Authors:  J A D'Antonio; W N Capello; W L Jaffe
Journal:  Clin Orthop Relat Res       Date:  1992-12       Impact factor: 4.176

3.  Short-term results of hydroxyapatite-coated primary total hip arthroplasty.

Authors:  P Rossi; P Sibelli; S Fumero; E Crua
Journal:  Clin Orthop Relat Res       Date:  1995-01       Impact factor: 4.176

4.  Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating.

Authors:  E W Morscher; A Hefti; U Aebi
Journal:  J Bone Joint Surg Br       Date:  1998-03

5.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

6.  Hydroxyapatite coated hip prosthesis followed up for 5 years.

Authors:  C J Oosterbos; A I Rahmy; A J Tonino
Journal:  Int Orthop       Date:  2001       Impact factor: 3.075

7.  Wear of polyethylene cups in total hip arthroplasty. A study of specimens retrieved post mortem.

Authors:  C J Sychterz; K H Moon; Y Hashimoto; K M Terefenko; C A Engh; T W Bauer
Journal:  J Bone Joint Surg Am       Date:  1996-08       Impact factor: 5.284

8.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

Authors:  D H Sochart
Journal:  Clin Orthop Relat Res       Date:  1999-06       Impact factor: 4.176

9.  Six-year results of hydroxyapatite-coated total hip replacement.

Authors:  R G Geesink; N H Hoefnagels
Journal:  J Bone Joint Surg Br       Date:  1995-07

10.  Polyethylene wear with an entirely HA-coated total hip replacement: 79 hips followed for 5 years.

Authors:  M Røkkum; A Reigstad
Journal:  Acta Orthop Scand       Date:  1998-06
View more
  1 in total

1.  Pre-surgical radiologic identification of peri-prosthetic osteolytic lesions around TKRs: a pre-clinical investigation of diagnostic accuracy.

Authors:  Timothy P Kurmis; Andrew P Kurmis; David G Campbell; John P Slavotinek
Journal:  J Orthop Surg Res       Date:  2008-10-03       Impact factor: 2.359

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.