Literature DB >> 7641466

Short-term results of hydroxyapatite-coated primary total hip arthroplasty.

P Rossi1, P Sibelli, S Fumero, E Crua.   

Abstract

One hundred consecutive patients who had Howmedica ABG total hip replacements, a system in which the femoral stem and the acetabular component are hydroxyapatite coated, during the period from September 1989 to January 1991 were studied prospectively. Clinical assessment using the d'Aubigné score showed that 96 patients had an excellent score at a minimum of 2 years from the operation. Radiographic analysis, based on DeLee and Charnley criteria for the acetabular cup and on Gruen criteria for the femoral stem, showed equally good results. There was good initial stability of the cup and the metaphyseal portion of the stem, with a secondary increase of load transmission in Zones 2 and 6 with cortical and cancellous thickening.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7641466

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

2.  Preoperative bone quality as a factor in dual-energy X-ray absorptiometry analysis comparing bone remodelling between two implant types.

Authors:  Bart Cornelis Hendrikus van der Wal; Ali Rahmy; Bernd Grimm; Ide Heyligers; Alphons Tonino
Journal:  Int Orthop       Date:  2006-11-04       Impact factor: 3.075

3.  Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova
Journal:  Int Orthop       Date:  2009-02-13       Impact factor: 3.075

4.  Early polyethylene wear and excessive acetabular granuloma in an uncemented HA-coated total hip arthroplasty--midterm results of a prospective study.

Authors:  Jörg Axel Karl Ohnsorge; Jack Davis; Uwe Maus; Muharrem Saklak; Markus Weisskopf; Dieter Christian Wirtz
Journal:  HSS J       Date:  2006-09

5.  The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Authors:  Chang-Dong Han; Keun-Young Shin; Hyun-Hee Lee; Kwan-Kyu Park; Ick-Hwan Yang; Woo-Suk Lee
Journal:  Hip Pelvis       Date:  2015-12-30

6.  The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem.

Authors:  Young-Yool Chung; Chae-Hyun Im; Dae-Hee Kim; Ju-Yeong Heo; Young-Jae Jang
Journal:  Hip Pelvis       Date:  2014-09-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.