Literature DB >> 12188477

Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of 85 Landos Atoll arthroplasties.

Kuo-An Lai1, Wun-Jer Shen, Chyun-Hsiang Chen, Chyun-Yu Yang, Wen-Pin Hu, Guang-Liang Chang.   

Abstract

Between March 1990 and May 1991 we performed 85 primary total hip replacements in 74 patients using the Landos Atoll hydroxyapatite (HA)-coated cup and the Corail HA-coated stem. The patients were followed up for a mean of ten years. Of the 85 cups, 26 (31%) have already been revised and a further six are radiologically unstable and awaiting revision. Two femoral stems have been revised for infection without loosening. The retrieved acetabular cups were studied by SEM and image-processing techniques to quantify the amount of residual HA on the cup. This was correlated with the clinical variables and modes of failure. The residual HA (as a percentage of the surface) on the loose cups correlated negatively with the duration of implantation (r = -0.732, p < 0.001). Six cups were stable at revision and had more residual HA coating than those which were loose (p < 0.01). The rate of failure of the Landos Atoll HA-coated, smooth hemispherical cup with screw fixation is unacceptably high. Resorption of the HA coating is markedly increased in loose cups compared with stable cups. HA coating cannot substitute for stable mechanical fixation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12188477     DOI: 10.1302/0301-620x.84b5.12384

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

2.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

3.  Long-term follow-up (11 years plus) results of JRI (Furlong) total hip arthroplasty in young patients: cause for concern regarding acetabular cup?

Authors:  D K Sharma; Stuart Brooks
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

4.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

5.  The Importance of Surface Technology in Spinal Fusion.

Authors:  Yoshihiro Katsuura; Joshua Wright-Chisem; Adam Wright-Chisem; Sohrab Virk; Steven McAnany
Journal:  HSS J       Date:  2020-02-12

6.  The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Authors:  Chang-Dong Han; Keun-Young Shin; Hyun-Hee Lee; Kwan-Kyu Park; Ick-Hwan Yang; Woo-Suk Lee
Journal:  Hip Pelvis       Date:  2015-12-30

7.  Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Göran Garellick; Johan Kärrholm
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

8.  Alumina-on-alumina in THA: a multicenter prospective study.

Authors:  Eduardo Garcia-Cimbrelo; Eduardo Garcia-Rey; Antonio Murcia-Mazón; Agustín Blanco-Pozo; Eduardo Martí
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

9.  A modified cementing technique using BoneSource to augment fixation of the acetabulum in a sheep model.

Authors:  A John Timperley; Iulian Nusem; Kathy Wilson; Sarah L Whitehouse; Pieter Buma; Ross W Crawford
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

10.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.