Hydroxylapatite-coated hip implants. Multicenter three-year clinical and roentgenographic results.

J A D'Antonio1, W N Capello, W L Jaffe.   

Abstract

The application of a thin coating of hydroxylapatite to total hip implants has provided the opportunity to realize stable fixation of a press-fit prosthesis without a porous coating or an intervening fibrous tissue layer. This series consists of 436 total hip arthroplasties, of which 320 cases have a minimum two-year follow-up period and 142 cases have a minimum three-year follow-up period. The femoral prosthesis used was a roughened titanium alloy with a 50-microns surface treatment of hydroxylapatite applied to the proximal one third. The acetabular components implanted included porous-coated implants (132), hydroxylapatite-coated acetabular shells of varying geometries (285), and bipolar implants (16). Analysis of the clinical results demonstrates a mean Harris Hip Score of 93 at six-months postarthroplasty, 95 at one and two years, and 96 at three years. At the three-year follow-up evaluation, 4.2% of patients complained of mild to moderate pain in the operative limb, whereas only 2.2% at two years and 1.4% at three years complained of activity-related thigh pain. The femoral mechanical loosening rate representing stems revised for aseptic loosening (two) plus roentgenographically unstable stems (zero) is 0.46%. Three hydroxylapatite-coated acetabular cups (1%) have shown measurable migration at two years, but none have been revised for aseptic loosening. The roentgenographic evaluation provides evidence for excellent proximal femoral fixation with distal stress transfer. Radiolucencies typically occur around the uncoated distal tip of the femoral stem (74%), but rarely in the proximal hydroxylapatite-coated anterior (3%) and lateral (2%) zones. Femoral cancellous condensation characteristically is seen at the transition zone of hydroxylapatite coated-to-uncoated stems (86%), whereas up to 32% of cases show cortical hypertrophy at the medial distal stem. These roentgenographic changes are progressive from one through three years postoperatively.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1446426

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

2.  Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty.

Authors:  T Gosens; E J van Langelaan
Journal:  Int Orthop       Date:  2005-05-18       Impact factor: 3.075

3.  [Animal experiments for testing a hydroxyapatite ceramic coating under vacuum conditions].

Authors:  R Kettner; S Jänicke; H J Schmitz
Journal:  Mund Kiefer Gesichtschir       Date:  1997-11

4.  Cementless total hip arthroplasty in Paget's disease of bone: a retrospective review.

Authors:  Julien Wegrzyn; Vincent Pibarot; Roland Chapurlat; Jean-Paul Carret; Jacques Béjui-Hugues; Olivier Guyen
Journal:  Int Orthop       Date:  2009-08-11       Impact factor: 3.075

5.  Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses.

Authors:  Alphons J Tonino; Bart C H van der Wal; Ide C Heyligers; Bernd Grimm
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

6.  Seven-year results of a tapered, titanium, hydroxyapatite-coated cementless femoral stem in primary total hip arthroplasty.

Authors:  Jin-Ho Cho; Jonathan P Garino; Suk-Kyu Choo; Kye-Young Han; Jung-Hoon Kim; Hyoung-Keun Oh
Journal:  Clin Orthop Surg       Date:  2010-11-05

7.  MicroRNA-26a-modified adipose-derived stem cells incorporated with a porous hydroxyapatite scaffold improve the repair of bone defects.

Authors:  Zhenlin Wang; Dawei Zhang; Zhiqiang Hu; Jiwei Cheng; Chuanmeng Zhuo; Xiancong Fang; Yongming Xing
Journal:  Mol Med Rep       Date:  2015-05-18       Impact factor: 2.952

8.  The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem.

Authors:  Young-Yool Chung; Chae-Hyun Im; Dae-Hee Kim; Ju-Yeong Heo; Young-Jae Jang
Journal:  Hip Pelvis       Date:  2014-09-29

9.  Uncemented fully hydroxyapatite-coated hip stem for intracapsular femoral neck fractures in osteoporotic elderly patients: a multicenter study.

Authors:  Fabrizio Rivera; Francesco Leonardi; Pietro Maniscalco; Marco Caforio; Roberto Capelli; Giampaolo Molinari; Paolo Esopi
Journal:  Arthroplast Today       Date:  2015-08-28

10.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359