Literature DB >> 9546458

Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating.

E W Morscher1, A Hefti, U Aebi.   

Abstract

One concern about the fixation of HA-coated implants is the possible disintegration of the surface, with the migration of HA granules into the joint space, producing third-body wear. We report a study of six revisions of HA-coated polyethylene RM cups at 9 to 14 years after successful primary arthroplasty. In all six hips, we found HA granules embedded in the articulating surface of the polyethylene, with abrasive wear of the cup and the metal femoral head. The cup had loosened in four hips and three showed severe osteolysis of the proximal femur. Third-body wear due to HA particles from implant coating may produce severe clinical problems with few early warning signs. Further clinical, radiological and histological observations are needed to determine the possible incidence of this late complication in the various types of coating of a variety of substrates.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9546458     DOI: 10.1302/0301-620x.80b2.8316

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  31 in total

1.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

2.  Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws.

Authors:  M Cimerman; A Cör; M Ceh; A Kristan; J Pizem; M Tonin
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

3.  Early polyethylene wear and excessive acetabular granuloma in an uncemented HA-coated total hip arthroplasty--midterm results of a prospective study.

Authors:  Jörg Axel Karl Ohnsorge; Jack Davis; Uwe Maus; Muharrem Saklak; Markus Weisskopf; Dieter Christian Wirtz
Journal:  HSS J       Date:  2006-09

4.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

5.  The Salto total ankle arthroplasty: survivorship and analysis of failures at 7 to 11 years.

Authors:  Michel Bonnin; Fabrice Gaudot; Jean-Raphael Laurent; Scott Ellis; Jean-Alain Colombier; Thierry Judet
Journal:  Clin Orthop Relat Res       Date:  2010-07-01       Impact factor: 4.176

6.  Local bisphosphonate release versus hydroxyapatite coating for stainless steel screw fixation in rat tibiae.

Authors:  F Agholme; T Andersson; P Tengvall; P Aspenberg
Journal:  J Mater Sci Mater Med       Date:  2011-12-28       Impact factor: 3.896

7.  A novel synthetic material for spinal fusion: a prospective clinical trial of porous bioactive titanium metal for lumbar interbody fusion.

Authors:  Shunsuke Fujibayashi; Mitsuru Takemoto; Masashi Neo; Tomiharu Matsushita; Tadashi Kokubo; Kenji Doi; Tatsuya Ito; Akira Shimizu; Takashi Nakamura
Journal:  Eur Spine J       Date:  2011-03-03       Impact factor: 3.134

8.  Is the bone-bonding ability of a cementless total hip prosthesis enhanced by alkaline and heat treatments?

Authors:  Kazutaka So; Ayumi Kaneuji; Tadami Matsumoto; Shuichi Matsuda; Haruhiko Akiyama
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Clinical and radiological results of hydroxyapatite-coated acetabular cups.

Authors:  J Blacha; J Gagała
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

10.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.