Literature DB >> 12703717

Speech recognition under conditions of frequency-place compression and expansion.

Deniz Baskent1, Robert V Shannon.   

Abstract

In normal acoustic hearing the mapping of acoustic frequency information onto the appropriate cochlear place is a natural biological function, but in cochlear implants it is controlled by the speech processor. The cochlear tonotopic range of the implant is determined by the length and insertion depth of the electrode array. Conventional cochlear implant electrode arrays are designed for an insertion of 25 mm inside the round window and the active electrodes occupy 16 mm, which would place the electrodes in a cochlear region corresponding to an acoustic frequency range of 500-6000 Hz. However, some implant speech processors map an acoustic frequency range from 150 to 10000 Hz onto these electrodes. While this mapping preserves the entire range of acoustic frequency information, it also results in a compression of the tonotopic pattern of speech information delivered to the brain. The present study measured the effects of such a compression of frequency-to-place mapping on speech recognition using acoustic simulations. Also measured were the effects of an expansion of the frequency-to-place mapping, which produces an expanded representation of speech in the cochlea. Such an expanded representation might improve speech recognition by improving the relative spatial (tonotopic) resolution, like an "acoustic fovea." Phoneme and sentence recognition was measured as a function of linear (in terms of cochlear distance) frequency-place compression and expansion. These conditions were presented to normal-hearing listeners using a noise-band vocoder, simulating cochlear implant electrodes with different insertion depths and different number of electrode channels. The cochlear tonotopic range was held constant by employing the same noise carrier bands for each condition, while the analysis frequency range was either compressed or expanded relative to the carrier frequency range. For each condition, the result was compared to that of the perfect frequency-place match, where the carrier and the analysis bands were perfectly matched. Speech recognition in the matched conditions was generally better than any condition of frequency-place expansion and compression, even when the matched condition eliminated a considerable amount of acoustic information. This result suggests that speech recognition, at least without training, is dependent on the mapping of acoustic frequency information onto the appropriate cochlear place.

Mesh:

Year:  2003        PMID: 12703717     DOI: 10.1121/1.1558357

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  35 in total

1.  Improving melody recognition in cochlear implant recipients through individualized frequency map fitting.

Authors:  Walter Di Nardo; Alessandro Scorpecci; Sara Giannantonio; Francesca Cianfrone; Gaetano Paludetti
Journal:  Eur Arch Otorhinolaryngol       Date:  2010-07-16       Impact factor: 2.503

2.  The effects of frequency-place shift on consonant confusion in cochlear implant simulations.

Authors:  Ning Zhou; Li Xu; Chao-Yang Lee
Journal:  J Acoust Soc Am       Date:  2010-07       Impact factor: 1.840

3.  Implications of deep electrode insertion on cochlear implant fitting.

Authors:  Mathieu Gani; Gregory Valentini; Alain Sigrist; Maria-Izabel Kós; Colette Boëx
Journal:  J Assoc Res Otolaryngol       Date:  2007-01-11

4.  Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants.

Authors:  Zachary M Smith; Bertrand Delgutte
Journal:  J Assoc Res Otolaryngol       Date:  2007-01-17

5.  Frequency map for the human cochlear spiral ganglion: implications for cochlear implants.

Authors:  Olga Stakhovskaya; Divya Sridhar; Ben H Bonham; Patricia A Leake
Journal:  J Assoc Res Otolaryngol       Date:  2007-02-21

6.  Forward-masked spatial tuning curves in cochlear implant users.

Authors:  David A Nelson; Gail S Donaldson; Heather Kreft
Journal:  J Acoust Soc Am       Date:  2008-03       Impact factor: 1.840

7.  Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion.

Authors:  Stephen J Rebscher; Alexander Hetherington; Ben Bonham; Peter Wardrop; David Whinney; Patricia A Leake
Journal:  J Rehabil Res Dev       Date:  2008

8.  Binaural benefit for speech recognition with spectral mismatch across ears in simulated electric hearing.

Authors:  Yang-soo Yoon; Aiguo Liu; Qian-Jie Fu
Journal:  J Acoust Soc Am       Date:  2011-08       Impact factor: 1.840

9.  Benefits of music training in mandarin-speaking pediatric cochlear implant users.

Authors:  Qian-Jie Fu; John J Galvin; Xiaosong Wang; Jiunn-Liang Wu
Journal:  J Speech Lang Hear Res       Date:  2015-02       Impact factor: 2.297

10.  Spectral and temporal analysis of simulated dead regions in cochlear implants.

Authors:  Jong Ho Won; Gary L Jones; Il Joon Moon; Jay T Rubinstein
Journal:  J Assoc Res Otolaryngol       Date:  2015-03-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.