Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy.

Nesrin Dogan1, Leonid B Leybovich, Anil Sethi.   

Abstract

Film dosimetry provides a convenient tool to determine dose distributions, especially for verification of IMRT plans. However, the film response to radiation shows a significant dependence on depth, energy and field size that compromise the accuracy of measurements. Kodak's XV2 film has a low saturation dose (approximately 100 cGy) and, consequently, a relatively short region of linear dose-response. The recently introduced Kodak extended range EDR2 film was reported to have a linear dose-response region extending to 500 cGy. This increased dose range may be particularly useful in the verification of IMRT plans. In this work, the dependence of Kodak EDR2 film's response on the depth, field size and energy was evaluated and compared with Kodak XV2 film. Co-60, 6 MV, 10 MV and 18 MV beams were used. Field sizes were 2 x 2, 6 x 6, 10 x 10, 14 x 14, 18 x 18 and 24 x 24 cm2. Doses for XV2 and EDR2 films were 80 cGy and 300 cGy, respectively. Optical density was converted to dose using depth-corrected sensitometric (Hurter and Driffield, or H&D) curves. For each field size, XV2 and EDR2 depth-dose curves were compared with ion chamber depth-dose curves. Both films demonstrated similar (within 1%) field size dependence. The deviation from the ion chamber for both films was small forthe fields ranging from 2 x 2 to 10 x 10 cm2: < or =2% for 6, 10 and 18 MV beams. No deviation was observed for the Co-60 beam. As the field size increased to 24 x 24 cm2, the deviation became significant for both films: approximately 7.5% for Co-60, approximately 5% for 6 MV and 10 MV, and approximately 6% for 18 MV. During the verification of IMRT plans, EDR2 film showed a better agreement with the calculated dose distributions than the XV2 film.

Entities:  

Mesh:

Year:  2002        PMID: 12476986     DOI: 10.1088/0031-9155/47/22/314

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Dosimetric verification in inhomogeneous phantom geometries for the XiO radiotherapy treatment planning system with 6-MV photon beams.

Authors:  Ryosuke Kohno; Satoshi Kitou; Eriko Hirano; Satoru Kameoka; Tomonori Goka; Teiji Nishio; Tomoko Miyagishi; Takaki Ariji; Mitsuhiko Kawashima; Takashi Ogino
Journal:  Radiol Phys Technol       Date:  2008-12-25

2.  Quasi-IMAT study with conventional equipment to show high plan quality with a single gantry arc.

Authors:  Judith Alvarez Moret; Oliver Kölbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

3.  A study on dosimetric properties of electronic portal imaging device and its use as a quality assurance tool in Volumetric Modulated Arc Therapy.

Authors:  Prabakar Sukumar; Sriram Padmanaban; Prakash Jeevanandam; S A Syam Kumar; Vivekanandan Nagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2011-08-26

4.  Anatomy-corresponding method of IMRT verification.

Authors:  Janusz Winiecki; Zbigniew Zurawski; Barbara Drzewiecka; Krzysztof Slosarek
Journal:  Rep Pract Oncol Radiother       Date:  2010-12-04

5.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

6.  Evaluation of relative transmitted dose for a step and shoot head and neck intensity modulated radiation therapy using a scanning liquid ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak
Journal:  J Med Phys       Date:  2012-01

7.  Analysis of the sources of uncertainty for EDR2 film-based IMRT quality assurance.

Authors:  Chengyu Shi; Nikos Papanikolaou; Yulong Yan; Xuejun Weng; Hongyu Jiang
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

8.  Radiographic film dosimetry for IMRT fields in the nearsurface buildup region.

Authors:  Peter L Roberson; Jean M Moran; Ravi Kulasekere
Journal:  J Appl Clin Med Phys       Date:  2008-10-24       Impact factor: 2.102

9.  Accuracy of rapid radiographic film calibration for intensity-modulated radiation therapy verification.

Authors:  Ravi Kulasekere; Jean M Moran; Benedick A Fraass; Peter L Roberson
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

10.  The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak; Paul Reich
Journal:  J Appl Clin Med Phys       Date:  2006-05-15       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.