Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.

P A Kyriacou1, S Powell, R M Langford, D P Jones.   

Abstract

Pulse oximeter probes attached to the finger may fail to estimate blood oxygen saturation (SpO2) in patients with compromised peripheral perfusion (e.g. hypothermic cardiopulmonary bypass surgery). The measurement of SpO2 from a central organ such as the oesophagus is suggested as an alternative to overcome this problem. A reflectance oesophageal pulse oximeter probe and a processing system implemented in LabVIEW were developed. The system was evaluated in clinical measurements on 50 cardiothoracic surgery patients. Oesophageal photoplethysmographic (PPG) signals with large amplitudes and high signal-to-noise ratios were measured from various depths within the oesophagus from all the cardiothoracic patients. The oesophageal PPG amplitudes from these patients were in good agreement with previous oesophageal PPG amplitude measurements from healthy anaesthetized patients. The oesophageal pulse oximeter SpO2 results agreed well with the estimated arterial oxygen saturation (SaO2) values inferred from the oxygen tension obtained by blood gas analysis. The mean (+/- SD) of the differences between the oesophageal pulse oximeter SpO2 readings and those from blood gas analysis was 0.02 +/- 0.88%. Also, the oesophageal pulse oximeter was found to be reliable and accurate in five cases of poor peripheral perfusion when a commercial finger pulse oximeter probe failed to estimate oxygen saturation values for at least 10 min. These results suggest that the arterial blood circulation to the oesophagus is less subject to vasoconstriction and decreased PPG amplitudes than are the peripheral sites used for pulse oximetry such as the finger. It is concluded that oesophageal SPO2 monitoring may be of clinical value.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12214761     DOI: 10.1088/0967-3334/23/3/305

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  10 in total

1.  Measuring venous oxygenation using the photoplethysmograph waveform.

Authors:  Zachary D Walton; Panayiotis A Kyriacou; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2010-07-20       Impact factor: 2.502

2.  Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry.

Authors:  K Shafqat; D P Jones; R M Langford; P A Kyriacou
Journal:  Med Biol Eng Comput       Date:  2006-07-21       Impact factor: 2.602

3.  A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states.

Authors:  Jong Yong A Foo; Stephen J Wilson
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

4.  SPECMAR: fast heart rate estimation from PPG signal using a modified spectral subtraction scheme with composite motion artifacts reference generation.

Authors:  Mohammad Tariqul Islam; Sk Tanvir Ahmed; Celia Shahnaz; Shaikh Anowarul Fattah
Journal:  Med Biol Eng Comput       Date:  2018-10-22       Impact factor: 2.602

5.  Can the descending aortic stroke volume be estimated by transesophageal descending aortic photoplethysmography?

Authors:  Peng Ling; Gong Quan; Yu Siyuan; Gao Bo; Wei Wei
Journal:  J Anesth       Date:  2017-03-27       Impact factor: 2.078

6.  Pulse transit time based on piezoelectric technique at the radial artery.

Authors:  Jong Yong Abdiel Foo; Chu Sing Lim
Journal:  J Clin Monit Comput       Date:  2006-05-16       Impact factor: 2.502

7.  The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

Authors:  Ling Mou; Quan Gong; Wei Wei; Bo Gao
Journal:  J Clin Monit Comput       Date:  2013-03-10       Impact factor: 2.502

Review 8.  Photoplethysmogram Analysis and Applications: An Integrative Review.

Authors:  Junyung Park; Hyeon Seok Seok; Sang-Su Kim; Hangsik Shin
Journal:  Front Physiol       Date:  2022-03-01       Impact factor: 4.566

9.  Multimodal Finger Pulse Wave Sensing: Comparison of Forcecardiography and Photoplethysmography Sensors.

Authors:  Emilio Andreozzi; Riccardo Sabbadini; Jessica Centracchio; Paolo Bifulco; Andrea Irace; Giovanni Breglio; Michele Riccio
Journal:  Sensors (Basel)       Date:  2022-10-06       Impact factor: 3.847

10.  A Novel Photoplethysmography Sensor for Vital Signs Monitoring from the Human Trachea.

Authors:  James M May; Justin P Phillips; Tracey Fitchat; Shankar Ramaswamy; Saowarat Snidvongs; Panayiotis A Kyriacou
Journal:  Biosensors (Basel)       Date:  2019-10-02
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.