A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states.

Jong Yong A Foo1, Stephen J Wilson.   

Abstract

Photoplethysmography (PPG) signals can be used in clinical assessment such as heart rate (HR) estimations and extraction of arterial flow waveforms. Motion artefact and/or poor peripheral perfusion can contaminate the PPG during monitoring. A computational system is presented here to minimise these two intrinsic weaknesses of the PPG signals. Specifically, accelerometers are used to detect the presence of motion artefacts and an adaptive filter is employed to minimise induced errors. Zero-phase digital filtering is engaged to reduce inaccuracy on the PPG signals when measured from a poorly perfused periphery. In this system, a decision matrix adopts the appropriate technique to improve the PPG signal-to-noise ratio dynamically. Statistical analyses show promising results (maximum error < 7.63%) when computed HR is compared to corresponding estimates from the electrocardiogram. Hence, the results here suggest that this dual-mode approach has potential for use in relevant clinical measurements.

Mesh:

Year:  2006        PMID: 16929932     DOI: 10.1007/s11517-005-0008-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  7 in total

1.  A new method for pulse oximetry possessing inherent insensitivity to artifact.

Authors:  M J Hayes; P R Smith
Journal:  IEEE Trans Biomed Eng       Date:  2001-04       Impact factor: 4.538

2.  Adaptive filtering in exercise high resolution ECG as applied to the hypertrophic cardiomyopathy.

Authors:  R Kepski; T Buchner; J Cytowski; L Malecka; F Walczak
Journal:  Pacing Clin Electrophysiol       Date:  2001-08       Impact factor: 1.976

3.  Extracting arterial flow waveforms from pulse oximeter waveforms apparatus.

Authors:  L B Cook
Journal:  Anaesthesia       Date:  2001-06       Impact factor: 6.955

4.  Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement.

Authors:  J Y A Foo; S J Wilson; G R Williams; M Harris; D M Cooper
Journal:  Australas Phys Eng Sci Med       Date:  2004-12       Impact factor: 1.430

5.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers.

Authors:  H J Luinge; P H Veltink
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

6.  Monitoring of respiratory and heart rates using a fibre-optic sensor.

Authors:  L G Lindberg; H Ugnell; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1992-09       Impact factor: 2.602

7.  Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.

Authors:  P A Kyriacou; S Powell; R M Langford; D P Jones
Journal:  Physiol Meas       Date:  2002-08       Impact factor: 2.833

  7 in total
  13 in total

1.  Spectral analysis of finger photoplethysmographic waveform variability in a model of mild to moderate haemorrhage.

Authors:  Paul M Middleton; Gregory S H Chan; Emma O'Lone; Elizabeth Steel; Rebecca Carroll; Branko G Celler; Nigel H Lovell
Journal:  J Clin Monit Comput       Date:  2008-10-11       Impact factor: 2.502

2.  Finger and ear photoplethysmogram waveform analysis by fitting with Gaussians.

Authors:  Uldis Rubins
Journal:  Med Biol Eng Comput       Date:  2008-10-15       Impact factor: 2.602

3.  Standardization of Stroke Perfusion CT for Reperfusion Therapy.

Authors:  Guangming Zhu; Patrik Michel; Weiwei Zhang; Max Wintermark
Journal:  Transl Stroke Res       Date:  2012-03-28       Impact factor: 6.829

4.  The acute effects of running on blood pressure estimation using pulse transit time in normotensive subjects.

Authors:  Mico Yee-Man Wong; Emma Pickwell-MacPherson; Yuan-Ting Zhang
Journal:  Eur J Appl Physiol       Date:  2009-06-20       Impact factor: 3.078

5.  Ideal filtering approach on DCT domain for biomedical signals: index blocked DCT filtering method (IB-DCTFM).

Authors:  Hang Sik Shin; Chungkeun Lee; Myoungho Lee
Journal:  J Med Syst       Date:  2009-04-30       Impact factor: 4.460

6.  A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction.

Authors:  Abdullah Alzahrani; Sijung Hu; Vicente Azorin-Peris
Journal:  Biosensors (Basel)       Date:  2015-06-08

Review 7.  Novel Flexible Wearable Sensor Materials and Signal Processing for Vital Sign and Human Activity Monitoring.

Authors:  Amir Servati; Liang Zou; Z Jane Wang; Frank Ko; Peyman Servati
Journal:  Sensors (Basel)       Date:  2017-07-13       Impact factor: 3.576

8.  Estimation of cardiac output and systemic vascular resistance using a multivariate regression model with features selected from the finger photoplethysmogram and routine cardiovascular measurements.

Authors:  Qim Y Lee; Stephen J Redmond; Gregory Sh Chan; Paul M Middleton; Elizabeth Steel; Philip Malouf; Cristopher Critoph; Gordon Flynn; Emma O'Lone; Nigel H Lovell
Journal:  Biomed Eng Online       Date:  2013-03-04       Impact factor: 2.819

9.  Reflective oxygen saturation monitoring at hypothenar and its validation by human hypoxia experiment.

Authors:  Tao Guo; Zhengtao Cao; Zhengbo Zhang; Deyu Li; Mengsun Yu
Journal:  Biomed Eng Online       Date:  2015-08-05       Impact factor: 2.819

10.  Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph.

Authors:  Kristen M Warren; Joshua R Harvey; Ki H Chon; Yitzhak Mendelson
Journal:  Sensors (Basel)       Date:  2016-03-07       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.